High-Throughput Isolation of Circulating Tumor Cells Using Cascaded Inertial Focusing Microfluidic Channel
The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
Circulating tumor cells (CTCs) are rare cells that detach from a primary or metastasis tumor and flow into the bloodstream. Intact and viable tumor cells are needed for genetic characterization of CTCs, new drug development, and other research. Although separation of CTCs using spiral channel with two outlets has been reported, few literature demonstrated simultaneous isolation of different types of CTCs from human blood using cascaded inertial focusing microfluidic channel. Herein, we introduce a cascaded microfluidic device consisting of two spiral channels and one zigzag channel designed with different fluid fields, including lift force, Dean drag force, and centrifugal force. Both red blood cells (RBCs)-lysed human blood spiked with CTCs and 1:50 diluted human whole blood spiked with CTCs were tested on the presented chip. This chip successfully separated RBCs, white blood cells (WBCs), and two different types of tumor cells (human lung cancer cells (A549) and human breast cancer cells (MCF-7)) simultaneously based on their physical properties. A total of 80.75% of A549 and 73.75% of MCF-7 were faithfully separated from human whole blood. Furthermore, CTCs gathered from outlets could propagate and remained intact. The cell viability of A549 and MCF-7 were 95% and 98%, respectively. The entire separating process for CTCs from blood cells could be finished within 20 min. The cascaded microfluidic device introduced in this study serves as a novel platform for simultaneous isolation of multiple types of CTCs from patient blood.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Cancer Metastasis: Building a Framework
Gupta, G. P., & Massagué, J. (2006) · Cell · doi:10.1016/j.cell.2006.11.001 · Cited by 4,247
Isolation and retrieval of circulating tumor cells using centrifugal forces
Hou, H. W., Warkiani, M. E., Khoo, B. L., Li, Z. R., Soo, R. A., Tan, D. S.-W., Lim, W.-T., Han, J., Bhagat, A. A. S., & Lim, C. T. (2013) · Scientific Reports · doi:10.1038/srep01259 · Cited by 736
Continuous particle separation in spiral microchannels using dean flows and differential migration
Bhagat, A. A. S., Kuntaegowdanahalli, S. S., & Papautsky, I. (2008) · Lab on a Chip · doi:10.1039/b807107a · Cited by 656
Zheng, S., Lin, H., Liu, J.-Q., Balic, M., Datar, R., Cote, R. J., & Tai, Y.-C. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.064 · Cited by 599
Deformability-based cell classification and enrichment using inertial microfluidics
Hur, S. C., Henderson-MacLennan, N. K., McCabe, E. R. B., & Di Carlo, D. (2011) · Lab on a Chip · doi:10.1039/c0lc00595a · Cited by 576
Ultra-fast, label-free isolation of circulating tumor cells from blood using spiral microfluidics
Warkiani, M. E., Khoo, B. L., Wu, L., Tay, A. K. P., Bhagat, A. A. S., Han, J., & Lim, C. T. (2016) · Nature Protocols · doi:10.1038/nprot.2016.003 · Cited by 548
High-throughput size-based rare cell enrichment using microscale vortices
Hur, S. C., Mach, A. J., & Di Carlo, D. (2011) · Biomicrofluidics · doi:10.1063/1.3576780 · Cited by 317
Guan, G., Wu, L., Bhagat, A. A., Li, Z., Chen, P. C. Y., Chao, S., Ong, C. J., & Han, J. (2013) · Scientific Reports · doi:10.1038/srep01475 · Cited by 279
Deterministic Separation of Cancer Cells from Blood at 10 mL/min
Loutherback, K., D'Silva, J., Liu, L., Wu, A., Austin, R., & Sturm, J. (2012) · Nature Precedings · doi:10.1038/npre.2012.6861.1 · Cited by 273
Rapid isolation of cancer cells using microfluidic deterministic lateral displacement structure
Liu, Z., Huang, F., Du, J., Shu, W., Feng, H., Xu, X., & Chen, Y. (2013) · Biomicrofluidics · doi:10.1063/1.4774308 · Cited by 220
Research works printed but not linked: 1
- 10.1063/1.4758131 · doi:10.1063/1.4758131 · Paper page
Cited by
Recent advances in gastric cancer early diagnosis
Necula, L., Matei, L., Dragu, D., Neagu, A. I., Mambet, C., Nedeianu, S., Bleotu, C., Diaconu, C. C., & Chivu-Economescu, M. (2019) · World Journal of Gastroenterology · doi:10.3748/wjg.v25.i17.2029 · Cited by 435
Zhou, J., Kulasinghe, A., Bogseth, A., O’Byrne, K., Punyadeera, C., & Papautsky, I. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0045-6 · Cited by 196
Progress of Inertial Microfluidics in Principle and Application
Gou, Y., Jia, Y., Wang, P., & Sun, C. (2018) · Sensors · doi:10.3390/s18061762 · Cited by 161
“Abdulla [93] demonstrated simultaneous isolation of different types of CTCs (A549 and MCF-7) from human blood using a cascaded inertial focusing microfluidic channel, consisting of two spiral-channels and one zigzag channel.”
MethodXiang, N., Wang, J., Li, Q., Yu, H., Huang, D., & Ni, Z. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02863 · Cited by 164
Applications of Microfluidics and Organ-on-a-Chip in Cancer Research
Regmi, S., Poudel, C., Adhikari, R., & Luo, K. Q. (2022) · Biosensors · doi:10.3390/bios12070459 · Cited by 143
“The balance between two or more forces in the channel causes particles (or bioparticles such as DNA, RNA, cells and proteins) to attain an equilibrium position in the microchannel and by controlling the flow rate, particles can be separated with high precision [18,19].”
Background
Metadata
- Authors
- Abdulla, A., Liu, W., Gholamipour-Shirazi, A., Sun, J., & Ding, X.
- Affiliations
- Shanghai Jiao Tong University (CN)
- State Key Laboratory of Oncogenes and Related Genes, Institute for Personalized Medicine, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China
- Corresponding author
- Ding, Xianting
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-03-14
- Volume
- 90
- Issue
- 7
- Pages
- 4397-4405
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2790914328
- Cited by
- 131
- References
- 51
- Citations by year
- 2026: 8 · 2025: 15 · 2024: 23 · 2023: 15 · 2022: 23 · 2021: 14 · 2020: 14 · 2019: 15 · 2018: 4
- FWCI
- 4.70
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Ministry of Science and Technology of the People's Republic of China (2017ZX10203205-006-002)
- Shanghai Municipaly (17DZ2203400, 2017SHZDZX01)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Field-Flow Fractionation Techniques
- Keywords
- circulating tumor cells, CTC isolation, inertial focusing, spiral channel, centrifugal force, hemolysis, whole blood separation, lung cancer cells, breast cancer cells, cell viability, high-throughput cell separation
- MeSH terms
- A549 Cells, Equipment Design, Humans, Neoplastic Cells, Circulating, Particle Size, Polystyrenes, Surface Properties, Tumor Cells, Cultured, Microfluidic Analytical Techniques, Optical Imaging, MCF-7 Cells, Healthy Volunteers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Throughput Isolation of Circulating Tumor Cells Using Cascaded Inertial Focusing Microfluidic Channel. https://app.cochat.ai/papers/10.1021/acs.analchem.7b04210
- The paper
- Abdulla, A., Liu, W., Gholamipour-Shirazi, A., Sun, J., & Ding, X. (2018). High-Throughput Isolation of Circulating Tumor Cells Using Cascaded Inertial Focusing Microfluidic Channel. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.7b04210
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.