CoChat

High-Throughput Isolation of Circulating Tumor Cells Using Cascaded Inertial Focusing Microfluidic Channel

Abdulla, Aynur, Liu, Wenjia, Gholamipour-Shirazi, Azarmidokht, Sun, Jiahui, Ding, Xianting · 2018 · Analytical Chemistry

The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.

Abstract

Circulating tumor cells (CTCs) are rare cells that detach from a primary or metastasis tumor and flow into the bloodstream. Intact and viable tumor cells are needed for genetic characterization of CTCs, new drug development, and other research. Although separation of CTCs using spiral channel with two outlets has been reported, few literature demonstrated simultaneous isolation of different types of CTCs from human blood using cascaded inertial focusing microfluidic channel. Herein, we introduce a cascaded microfluidic device consisting of two spiral channels and one zigzag channel designed with different fluid fields, including lift force, Dean drag force, and centrifugal force. Both red blood cells (RBCs)-lysed human blood spiked with CTCs and 1:50 diluted human whole blood spiked with CTCs were tested on the presented chip. This chip successfully separated RBCs, white blood cells (WBCs), and two different types of tumor cells (human lung cancer cells (A549) and human breast cancer cells (MCF-7)) simultaneously based on their physical properties. A total of 80.75% of A549 and 73.75% of MCF-7 were faithfully separated from human whole blood. Furthermore, CTCs gathered from outlets could propagate and remained intact. The cell viability of A549 and MCF-7 were 95% and 98%, respectively. The entire separating process for CTCs from blood cells could be finished within 20 min. The cascaded microfluidic device introduced in this study serves as a novel platform for simultaneous isolation of multiple types of CTCs from patient blood.

Overview

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.7b04210

Cites

51 of 51 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 51 references

Research works printed but not linked: 1

  1. 10.1063/1.4758131 · doi:10.1063/1.4758131 · Paper page

Cited by

Items 101–135 of 135

Metadata

Authors
Abdulla, A., Liu, W., Gholamipour-Shirazi, A., Sun, J., & Ding, X.
Affiliations
  • Shanghai Jiao Tong University (CN)
  • State Key Laboratory of Oncogenes and Related Genes, Institute for Personalized Medicine, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China
Corresponding author
Ding, Xianting
Venue
Analytical Chemistry
Published
2018-03-14
Volume
90
Issue
7
Pages
4397-4405
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2790914328
Cited by
131
References
51
Citations by year
2026: 8 · 2025: 15 · 2024: 23 · 2023: 15 · 2022: 23 · 2021: 14 · 2020: 14 · 2019: 15 · 2018: 4
FWCI
4.70
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Ministry of Science and Technology of the People's Republic of China (2017ZX10203205-006-002)
  • Shanghai Municipaly (17DZ2203400, 2017SHZDZX01)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Chemistry › Analytical Chemistry › Field-Flow Fractionation Techniques
Keywords
circulating tumor cells, CTC isolation, inertial focusing, spiral channel, centrifugal force, hemolysis, whole blood separation, lung cancer cells, breast cancer cells, cell viability, high-throughput cell separation
MeSH terms
A549 Cells, Equipment Design, Humans, Neoplastic Cells, Circulating, Particle Size, Polystyrenes, Surface Properties, Tumor Cells, Cultured, Microfluidic Analytical Techniques, Optical Imaging, MCF-7 Cells, Healthy Volunteers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.