CoChat

Multiplexed Middle-Down Mass Spectrometry as a Method for Revealing Light and Heavy Chain Connectivity in a Monoclonal Antibody

Open access
Srzentić, Kristina, Nagornov, Konstantin O., Fornelli, Luca, Lobas, Anna A., Ayoub, Daniel, Kozhinov, Anton N., Gasilova, Natalia, Menin, Laure, Beck, Alain, Gorshkov, Mikhail V., Aizikov, Konstantin, Tsybin, Yury O. · 2018 · Analytical Chemistry
Cited by 57

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Pairing light and heavy chains in monoclonal antibodies (mAbs) using top-down (TD) or middle-down (MD) mass spectrometry (MS) may complement the sequence information on single chains provided by high-throughput genomic sequencing and bottom-up proteomics, favoring the rational selection of drug candidates. The 50 kDa F(ab) subunits of mAbs are the smallest structural units that contain the required information on chain pairing. These subunits can be enzymatically produced from whole mAbs and interrogated in their intact form by TD/MD MS approaches. However, the high structural complexity of F(ab) subunits requires increased sensitivity of the modern TD/MD MS for a comprehensive structural analysis. To address this and similar challenges, we developed and applied a multiplexed TD/MD MS workflow based on spectral averaging of tandem mass spectra (MS/MS) across multiple liquid chromatography (LC)-MS/MS runs acquired in reduced or full profile mode using an Orbitrap Fourier transform mass spectrometer (FTMS). We first benchmark the workflow using myoglobin as a reference protein, and then validate it for the analysis of the 50 kDa F(ab) subunit of a therapeutic mAb, trastuzumab. Obtained results confirm the envisioned benefits in terms of increased signal-to-noise ratio of product ions from utilizing multiple LC-MS/MS runs for TD/MD protein analysis using mass spectral averaging. The workflow performance is compared with the earlier introduced multiplexed TD/MD MS workflow based on transient averaging in Orbitrap FTMS. For the latter, we also report on enabling absorption mode FT processing and demonstrate its comparable performance to the enhanced FT (eFT) spectral representation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.8b02398

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 57

Metadata

Authors
Srzentić, K., Nagornov, K. O., Fornelli, L., Lobas, A. A., Ayoub, D., Kozhinov, A. N., Gasilova, N., Menin, L., Beck, A., Gorshkov, M. V., Aizikov, K., & Tsybin, Y. O.
Venue
Analytical Chemistry
Published
2018-09-25
Volume
90
Issue
21
Pages
12527-12535
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2893146965
Cited by
57
References
6
FWCI
2.78
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.