Battery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat

Open access

Abstract

Battery-free, wireless microfluidic/electronic system for multiparameter sweat analysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1126/sciadv.aav3294

Cites

51 of 51 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Device concept. (A) Schematic illustrating the exploded view of the complete hybrid battery-free system. PI, polyimide; S.R., sweat rate. Close-up image of (B) microfluidic patch with embedded sensors and (C) battery-free NFC electronics. (D) Image illustrating the reversible magnetic attachment of the NFC electronics to the microfluidic patch. (E) Image of the complete system. (F) Image illustrating the device during sweating. (G) A phone interface that illustrates wireless communication and image acquisition. Photo credit: Philipp Gutruf, Northwestern University.
Fig. 1 Device concept. (A) Schematic illustrating the exploded view of the complete hybrid battery-free system. PI, polyimide; S.R., sweat rate. Close-up image of (B) microfluidic patch with embedded sensors and (C) battery-free NFC electronics. (D) Image illustrating the reversible magnetic attachment of the NFC electronics to the microfluidic patch. (E) Image of the complete system. (F) Image illustrating the device during sweating. (G) A phone interface that illustrates wireless communication and image acquisition. Photo credit: Philipp Gutruf, Northwestern University.CC BY-NC · PubMed Central
Fig. 2 Electrical characterization of the NFC electronics. (A) Simplified schematic illustration of electrochemical sensor readout. ADC, analog-to-digital converter. (B) Image illustrating the device bent at decreasing radii. (C) I-V measurements of shorted sensors recoded with decreasing curvature radii. (D) Phase response measurements of NFC electronics with decreasing radii. (E) I-V measurements of shorted sensors with repeated attachment and detachment of the electronics to the microfluidics. (F) Effect of bending on the impedance of magnetic contacts over a wide range of frequencies. Effect of (G) distance and (H) angle between NFC reader and device on signal recording (n = 3). Photo credit: Philipp Gutruf, Northwestern University.
Fig. 2 Electrical characterization of the NFC electronics. (A) Simplified schematic illustration of electrochemical sensor readout. ADC, analog-to-digital converter. (B) Image illustrating the device bent at decreasing radii. (C) I-V measurements of shorted sensors recoded with decreasing curvature radii. (D) Phase response measurements of NFC electronics with decreasing radii. (E) I-V measurements of shorted sensors with repeated attachment and detachment of the electronics to the microfluidics. (F) Effect of bending on the impedance of magnetic contacts over a wide range of frequencies. Effect of (G) distance and (H) angle between NFC reader and device on signal recording (n = 3). Photo credit: Philipp Gutruf, Northwestern University.CC BY-NC · PubMed Central
Fig. 3 Lactate sensor characterization. (A) Exploded-view schematic illustration of the layer makeup of the biofuel cell–based lactate sensor. LOx, lactate oxidase; TTF, tetrathiafulvalene. (B) Image of the lactate sensor. (C) Real-time sensor response to increasing lactate concentration in phosphate buffer (pH 7.0) at 25°C and (D) the corresponding calibration (n = 3). (E) Plot illustrating a reversible response for the lactate sensor for four consecutive cycles of varying lactate concentration. Inset shows calibration plot that compares the sensor signal in (E) for the four cycles. V, voltage in millivolts; C, concentration in millimolar. (F) Real-time data acquired with increasing lactate concentration in artificial sweat under common physiological sweat conditions [temperature, ~30°C (pH 5.5)]. (G) Calibration plot obtained from lactate sensors at ~30°C in artificial sweat with different pH (n = 3). Photo credit: Philipp Gutruf, Northwestern University.
Fig. 3 Lactate sensor characterization. (A) Exploded-view schematic illustration of the layer makeup of the biofuel cell–based lactate sensor. LOx, lactate oxidase; TTF, tetrathiafulvalene. (B) Image of the lactate sensor. (C) Real-time sensor response to increasing lactate concentration in phosphate buffer (pH 7.0) at 25°C and (D) the corresponding calibration (n = 3). (E) Plot illustrating a reversible response for the lactate sensor for four consecutive cycles of varying lactate concentration. Inset shows calibration plot that compares the sensor signal in (E) for the four cycles. V, voltage in millivolts; C, concentration in millimolar. (F) Real-time data acquired with increasing lactate concentration in artificial sweat under common physiological sweat conditions [temperature, ~30°C (pH 5.5)]. (G) Calibration plot obtained from lactate sensors at ~30°C in artificial sweat with different pH (n = 3). Photo credit: Philipp Gutruf, Northwestern University.CC BY-NC · PubMed Central
Fig. 4 Glucose sensor characterization. (A) Exploded-view schematic illustration of the layer makeup of the biofuel cell–based glucose sensor. GOx, glucose oxidase; PtC, platinized carbon. (B) Image of the glucose sensor. (C) Real-time sensor response to increasing glucose concentration in phosphate buffer (pH 7.0) at 25°C and (D) the corresponding calibration (n = 3). (E) Plot illustrating the reversible response of the glucose sensor for four consecutive cycles of varying glucose concentration. V, voltage in millivolts; C, concentration in micromolar. Inset shows calibration plot comparing the sensor signal plotted in (E) for the four cycles. (F) Real-time data acquired with increasing glucose concentration in artificial sweat under common physiological sweat conditions [temperature, ~30°C (pH 5.5)]. (G) Calibration plot obtained from glucose sensors at ~30°C in artificial sweat with different pH (n = 3). Photo credit: Philipp Gutruf, Northwestern University.
Fig. 4 Glucose sensor characterization. (A) Exploded-view schematic illustration of the layer makeup of the biofuel cell–based glucose sensor. GOx, glucose oxidase; PtC, platinized carbon. (B) Image of the glucose sensor. (C) Real-time sensor response to increasing glucose concentration in phosphate buffer (pH 7.0) at 25°C and (D) the corresponding calibration (n = 3). (E) Plot illustrating the reversible response of the glucose sensor for four consecutive cycles of varying glucose concentration. V, voltage in millivolts; C, concentration in micromolar. Inset shows calibration plot comparing the sensor signal plotted in (E) for the four cycles. (F) Real-time data acquired with increasing glucose concentration in artificial sweat under common physiological sweat conditions [temperature, ~30°C (pH 5.5)]. (G) Calibration plot obtained from glucose sensors at ~30°C in artificial sweat with different pH (n = 3). Photo credit: Philipp Gutruf, Northwestern University.CC BY-NC · PubMed Central
Fig. 5 Colorimetric assay characterization. Calibration and corresponding color evolution for physiologically relevant levels of (A) chloride (n = 3) and (B) pH (n = 3). (C) Filling of sweat rate sensor. The arrow indications the direction of filling. (D) Image illustrating the chrono-sampling feature of the microfluidic system. Photo credit: Jungil Choi and Jonathan Reeder, Northwestern University.
Fig. 5 Colorimetric assay characterization. Calibration and corresponding color evolution for physiologically relevant levels of (A) chloride (n = 3) and (B) pH (n = 3). (C) Filling of sweat rate sensor. The arrow indications the direction of filling. (D) Image illustrating the chrono-sampling feature of the microfluidic system. Photo credit: Jungil Choi and Jonathan Reeder, Northwestern University.CC BY-NC · PubMed Central
Fig. 6 Human trials. (A) Photograph of a subject wearing a wireless battery-free hybrid sensor system. (B) Reading distance with a large NFC antenna. (C) Image of complete system captured after a bout of cycling by subject #1. Real-time wirelessly acquired sweat concentration levels for (D) lactate and (E) glucose, respectively. (F) Image of complete system captured after a bout of cycling by subject #2. Real-time wirelessly acquired sweat concentration levels for (G) lactate and (H) glucose, respectively. (D, E, G, and H) Blue and green regions represent conditions before and after collection of sweat, respectively. Photo credit: Philipp Gutruf, Northwestern University.
Fig. 6 Human trials. (A) Photograph of a subject wearing a wireless battery-free hybrid sensor system. (B) Reading distance with a large NFC antenna. (C) Image of complete system captured after a bout of cycling by subject #1. Real-time wirelessly acquired sweat concentration levels for (D) lactate and (E) glucose, respectively. (F) Image of complete system captured after a bout of cycling by subject #2. Real-time wirelessly acquired sweat concentration levels for (G) lactate and (H) glucose, respectively. (D, E, G, and H) Blue and green regions represent conditions before and after collection of sweat, respectively. Photo credit: Philipp Gutruf, Northwestern University.CC BY-NC · PubMed Central
Fig. 7 Human trails. Correlation of data acquired from biofuel cell–based glucose and lactate sweat sensors with that acquired from blood glucose and lactate meters, respectively, over a period of (A) 2 days and (B) 1 day for subject #1 (with time lag compensation). Photo credit: Philipp Gutruf, Northwestern University.
Fig. 7 Human trails. Correlation of data acquired from biofuel cell–based glucose and lactate sweat sensors with that acquired from blood glucose and lactate meters, respectively, over a period of (A) 2 days and (B) 1 day for subject #1 (with time lag compensation). Photo credit: Philipp Gutruf, Northwestern University.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 51 references

Cited by

See all 761

Metadata

Authors
Bandodkar, A. J., Gutruf, P., Choi, J., Lee, K., Sekine, Y., Reeder, J. T., Jeang, W. J., Aranyosi, A. J., Lee, S. P., Model, J. B., Ghaffari, R., Su, C.-J., Leshock, J. P., Ray, T., Verrillo, A., Thomas, K., Krishnamurthi, V., Han, S., Kim, J., Krishnan, S., Hang, T., & Rogers, J. A.
Affiliations
  • Northwestern University (US)
  • Japan Atomic Energy Agency (JP)
  • Washington University in St. Louis (US)
  • RMIT University (AU)
  • Ajou University (KR)
  • Kwangwoon University (KR)
  • Shanghai Jiao Tong University (CN)
Corresponding author
  • Bandodkar, Amay J.
  • Gutruf, Philipp
  • Choi, Jungil
  • Rogers, John A.
Venue
Science Advances
Published
2019-01-04
Volume
5
Issue
1
Pages
eaav3294-eaav3294
ISSN
2375-2548 (ISSN-L)
OpenAlex
W2908711986
Cited by
761
References
51
Citations by year
2026: 84 · 2025: 104 · 2024: 95 · 2023: 115 · 2022: 115 · 2021: 119 · 2020: 82 · 2019: 46
FWCI
31.78
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • Science Advances (publishedVersion, cc-by-nc)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • UA Campus Repository (The University of Arizona) (acceptedVersion, cc-by-nc)
  • RMIT Research Repository (RMIT University Library) (submittedVersion, cc-by-nc)
  • Figshare (submittedVersion, cc-by-nc)
Funders
Air Force Research Laboratory (FA8650-14-D-6516)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
Keywords
wearable sweat sensors, battery-free electronics, microfluidic platform, colorimetric assay, wireless sensing, sweat glucose, sweat lactate, sweat pH, sweat chloride, sweat rate
MeSH terms
Wearable Electronic Devices, Bioelectric Energy Sources, Chlorides, Colorimetry, Glucose, Humans, Hydrogen-Ion Concentration, Male, Skin, Sweat, Biosensing Techniques, Lactic Acid, Microfluidics, Lab-On-A-Chip Devices, Healthy Volunteers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Battery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat. https://app.cochat.ai/papers/10.1126/sciadv.aav3294
The paper
Bandodkar, A. J., Gutruf, P., Choi, J., Lee, K., Sekine, Y., Reeder, J. T., Jeang, W. J., Aranyosi, A. J., Lee, S. P., Model, J. B., Ghaffari, R., Su, C.-J., Leshock, J. P., Ray, T., Verrillo, A., Thomas, K., Krishnamurthi, V., Han, S., Kim, J., . . . Rogers, J. A. (2019). Battery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat. Science Advances. https://doi.org/10.1126/sciadv.aav3294

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.