The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Emerging Designs of Activatable Photoacoustic Probes for Molecular Imaging
Open accessAbstract
Photoacoustic (PA) imaging as a new hybrid imaging modality holds great promise for real-time in vivo monitoring of biological processes with deep tissue penetration and high spatial resolution. To endow PA imaging with the ability to provide real-time molecular information at disease sites, molecular probes that can change their PA signals responding to the target or event of interest have to be developed. This review focuses on the recent development of smart activatable PA probes for molecular imaging. A brief summary of PA imaging agents is given first, followed by the detailed discussion of the contemporary design approaches toward activatable PA probes for different imaging applications. At last, the current challenges are highlighted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Origin and physiological roles of inflammation
Medzhitov, R. (2008) · Nature · doi:10.1038/nature07201 · Cited by 6,618
New functions for the matrix metalloproteinases in cancer progression
Egeblad, M., & Werb, Z. (2002) · Nature Reviews Cancer · doi:10.1038/nrc745 · Cited by 6,108
Matrix Metalloproteinases: Regulators of the Tumor Microenvironment
Kessenbrock, K., Plaks, V., & Werb, Z. (2010) · Cell · doi:10.1016/j.cell.2010.03.015 · Cited by 5,151
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Neurodegenerative diseases and oxidative stress
Barnham, K. J., Masters, C. L., & Bush, A. I. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1330 · Cited by 3,683
Peroxynitrite: biochemistry, pathophysiology and development of therapeutics
Szabó, C., Ischiropoulos, H., & Radi, R. (2007) · Nature Reviews Drug Discovery · doi:10.1038/nrd2222 · Cited by 2,134
Photoacoustic Doppler Effect from Flowing Small Light-Absorbing Particles
Fang, H., Maslov, K., & Wang, L. V. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.184501 · Cited by 171
Cited by
Photothermal therapy and photoacoustic imaging via nanotheranostics in fighting cancer
Liu, Y., Bhattarai, P., Dai, Z., & Chen, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00618k · Cited by 2,904
Li, J., & Pu, K. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00001h · Cited by 1,168
Self-citationRatiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 820
Ultralong Phosphorescence of Water‐Soluble Organic Nanoparticles for In Vivo Afterglow Imaging
Zhen, X., Tao, Y., An, Z., Chen, P., Xu, C., Chen, R., Huang, W., & Pu, K. (2017) · Advanced Materials · doi:10.1002/adma.201606665 · Cited by 602
Self-citationHuang, J., & Pu, K. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.202001783 · Cited by 541
Self-citation
Metadata
- Authors
- Miao, Q., & Pu, K.
- Venue
- Bioconjugate Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-12-08
- Volume
- 27
- Issue
- 12
- Pages
- 2808-2823
- ISSN
- 1043-1802 (ISSN-L)
- 1520-4812
- OpenAlex
- W2550285453
- Cited by
- 173
- References
- 7
- FWCI
- 14.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.