High-Temperature Corrosion Behavior of Superheater Materials at 600 °C: Insights from Laboratory and Field Exposures

Open access
Ssenteza, Vicent, Olausson, Maria Dolores Paz, Eklund, Johan, Nockert, Johanna, Liske, Jesper, Jonsson, Torbjörn · 2025 · Energy & Fuels

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index; 5 of the 16 sources its claims cite were checked for support.

Abstract

Combustion of biomass and waste results in release of corrosive species, such as alkali chlorides and water vapor, which accelerate the corrosion of superheaters in the boiler. To improve our understanding of alkali-induced corrosion, long-term corrosion investigations are needed. This study utilizes a systematic approach based on long-term corrosion studies (up to 8000 h) in a well-controlled laboratory environment to understand the corrosion behavior and protectiveness of oxide scales formed on a FeCr alloy (marginal chromia former) and three overlay weld coating systems (lean FeCrAl, FeCrAl, and Ni-based alloy) in a KCl-rich environment at 600 °C. The results show that all the alloys undergo fast breakaway corrosion and form duplex-layered scales consisting of outward- and inward-growing oxide scales. The marginal chromia former exhibits parabolic oxidation kinetics and forms Fe-rich oxides in the outer scale and mixed Fe- and Cr-oxides in the inner layer. These oxide microstructures are compared to the scales formed on probe-exposed samples in boilers, and similar microstructures are typically found after exposures. The FeCrAl coatings form Fe-rich oxides in the outer layer and Fe-, Cr-, and Al-oxides in the inner layer. All alloy systems except the Ni-based coating show corrosion rates in the boiler in good agreement with the laboratory test prediction. The Ni-based coating exhibits the slowest oxidation kinetics in the laboratory, forming thin oxide scales with Ni-rich oxides in the outer layer and Cr-rich oxides in the inner layers, while this is not the case in the waste-fired boiler.

Overview

CoChat Summary

TL;DR

Long-term laboratory and field exposures at 600 °C show that a marginal chromia former and three overlay coatings all undergo breakaway corrosion in KCl-rich biomass/waste boiler-like conditions, forming duplex outward/inward oxide scales. Laboratory parabolic kinetics predict field oxide thickness well for most alloys, except the Ni-based coating, which corrodes faster in the waste-fired boiler due to Cl and high flue-gas temperature.

Key findings

  • All investigated materials underwent breakaway oxidation after the shortest laboratory exposure of 168 h at 600 °C in 5% O2 + 20% H2O + N2 with 2 mg/cm² KCl, forming multilayered outward- and inward-growing oxide scales; K2CrO4 particles formed at the surface of all materials.
  • Laboratory parabolic rate constants were 0.0256 μm²/s for the marginal chromia former, 0.0216 μm²/s for lean FeCrAl, 0.0149 μm²/s for FeCrAl, and 0.0051 μm²/s for the Ni-based coating. The marginal chromia former grew from ∼90 to ∼206 μm after 168 and 8000 h, while the Ni-based alloy formed 13–42 μm scales after 8000 h.
  • After 8000 h, inner-scale Cr enrichment reached 55 at % for lean FeCrAl and 70 at % for FeCrAl; the Ni-based coating had Cr-rich inner scales of 80 at % after 168 h and 90 at % after 8000 h.
  • Field oxide thicknesses agreed with laboratory predictions for most alloys: marginal chromia former 150 μm measured vs 148 μm calculated after 3000 h; FeCrAl 70 μm measured vs 69 μm calculated after 3000 h. The Ni-based coating was the exception: 120 μm measured after 1000 h in the waste-fired boiler vs 25 μm calculated, with up to 30% Cl detected within the oxide and 6.5 wt % Cl in the deposit.

Methods

  • Four material/coating systems were tested: a marginal chromia former ferritic-martensitic stainless steel, a lean FeCrAl coating with 12.4 wt % Cr, a normal FeCrAl coating with 21 wt % Cr, and a Ni-based coating. Laboratory coupons and field ring samples were produced by overlay welding.
  • Laboratory exposures used 2 mg/cm² KCl predeposited on samples, then exposure in 5% O2 + 20% H2O + N2 (balance) at 600 °C for 168, 500, 1000, and 8000 h. Field exposures were at 600 °C in three commercial boilers: marginal chromia former and FeCrAl for 3000 h in a BFB boiler, lean FeCrAl for 2000 h in a wood-chip BFB boiler, and Ni-based alloy for 1000 h in a waste-fired grate boiler.
  • Postexposure analysis used SEM/EDX on cross sections prepared by broad ion beam milling, ImageJ oxide thickness measurements, and ion chromatography for Cl⁻ and SO4²⁻ in deposits. Parabolic rate constants were determined from long-term laboratory exposures.

Limitations

  • Stated: the study considers the propagation phase and not the initiation phase; the initial phase before 168 h may have a different kp value.
  • Stated: field samples can experience changes in flue gas velocity or temperature, thermal cycling, and varying deposit thickness, and outer oxide scale can spall during exposure or handling. For lean FeCrAl in the field, only the inward-growing layer (50 μm) was recovered, so the predicted total thickness was 100 μm.
  • Evident from the text: field exposures used different boilers, fuels, and durations for different alloys, so direct laboratory-to-field comparisons across materials are not fully controlled.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1021/acs.energyfuels.4c04806

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Oxidation kinetics based on oxide thickness measurements after exposure in laboratory environment (O2+H2O+KCl) at 600 °C. The oxide thickness for the samples tested in laboratory was measured from the SEM cross-section images using ImageJ software.
Figure 1 Oxidation kinetics based on oxide thickness measurements after exposure in laboratory environment (O2+H2O+KCl) at 600 °C. The oxide thickness for the samples tested in laboratory was measured from the SEM cross-section images using ImageJ software.CC BY · PubMed Central
Figure 2 SEM-BSE cross-section images showing the oxide microstructure after exposure in laboratory environment (O2+H2O+KCl) and biomass- and waste-fired boiler environments at 600 °C.
Figure 2 SEM-BSE cross-section images showing the oxide microstructure after exposure in laboratory environment (O2+H2O+KCl) and biomass- and waste-fired boiler environments at 600 °C.CC BY · PubMed Central

Verification

Claims the paper makes

4 Valid · 2 Not valid · 2 Not checked · 40 Own results and interpretations

16 more claims

Create a free account to see all 48 claims and to verify the 3 references still open.

See all claims — free account
  • Borderline: one of the tests for a substantial claim is unclear. 3
  • It may state two separate claims as one. 26
  • The quote only partly states this claim. 3

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

2 of 2

Citations

Cites

Show all 38 references

Research works printed but not linked: 3

  1. Mcnallan M., 1983, NACE, 316
  2. 10.1016/0010-938X(95)00011-8 · DOI · Paper page
  3. 10.1002/maco.201005942 · DOI · Paper page

Metadata

Authors
Ssenteza, V., Olausson, M. D. P., Eklund, J., Nockert, J., Liske, J., & Jonsson, T.
Affiliations
  • Chalmers University of Technology (SE)
  • Chalmers University of Technology, Kemivägen 10, 412 96 Gothenburg, Sweden
  • Valmet (Sweden) (SE)
  • Kanthal (Sweden) (SE)
Corresponding author
Ssenteza, Vicent
Venue
Energy & Fuels
Published
2024-12-12
Volume
39
Issue
1
Pages
819-827
ISSN
  • 0887-0624 (ISSN-L)
  • 1520-5029
OpenAlex
W4405307976
Cited by
1
References
38
Citations by year
2026: 1
FWCI
0.17
Type
journal article
Language
en
Open access
Locations
  • Energy & Fuels (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Chalmers Research (Chalmers University of Technology) (submittedVersion)
Funders
H2020 Energy (815147)
Topics
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › High-Temperature Coating Behaviors
  • Physical Sciences › Engineering › Mechanical Engineering › High Temperature Alloys and Creep
  • Physical Sciences › Materials Science › Materials Chemistry › Corrosion Behavior and Inhibition
Keywords
high-temperature corrosion, oxide scale formation, breakaway corrosion, oxidation kinetics, boiler corrosion

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Temperature Corrosion Behavior of Superheater Materials at 600 °C: Insights from Laboratory and Field Exposures. https://app.cochat.ai/papers/10.1021/acs.energyfuels.4c04806
The paper
Ssenteza, V., Olausson, M. D. P., Eklund, J., Nockert, J., Liske, J., & Jonsson, T. (2025). High-Temperature Corrosion Behavior of Superheater Materials at 600 °C: Insights from Laboratory and Field Exposures. Energy & Fuels. https://doi.org/10.1021/acs.energyfuels.4c04806

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.