The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
S-Trap, an Ultrafast Sample-Preparation Approach for Shotgun Proteomics
Abstract
The success of shotgun proteomic analysis depends largely on how samples are prepared. Current approaches (such as those that are gel-, solution-, or filter-based), although being extensively employed in the field, are time-consuming and less effective with respect to the repetitive sample processing, recovery, and overall yield. As an alternative, the suspension trapping (S-Trap) filter has been commercially available very recently in the format of a single or 96-well filter plate. In contrast to the conventional filter-aided sample preparation (FASP) approach, which utilizes a molecular weight cut-off (MWCO) membrane as the filter and requires hours of processing before digestion-ready proteins can be obtained, the S-Trap employs a three-dimensional porous material as filter media and traps particulate protein suspensions with the subsequent depletion of interfering substances and in-filter digestion. Due to the large (submicron) pore size, each centrifugation cycle of the S-Trap filter only takes 1 min, which significantly reduces the total processing time from approximately 3 h by FASP to less than 15 min, suggesting an ultrafast sample-preparation approach for shotgun proteomics. Here, we comprehensively evaluate the performance of the individual S-Trap filter and 96-well filter plate in the context of global protein identification and quantitation using whole-cell lysate and clinically relevant sputum samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Universal sample preparation method for proteome analysis
Wiśniewski, J. R., Zougman, A., Nagaraj, N., & Mann, M. (2009) · Nature Methods · doi:10.1038/nmeth.1322 · Cited by 8,352
2016 update of the PRIDE database and its related tools
Vizcaíno, J. A., Csordas, A., del-Toro, N., Dianes, J. A., Griss, J., Lavidas, I., Mayer, G., Perez-Riverol, Y., Reisinger, F., Ternent, T., et al. (2016) · Nucleic Acids Research · doi:10.1093/nar/gkv1145 · Cited by 3,451
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Suspension trapping (STrap) sample preparation method for bottom‐up proteomics analysis
Zougman, A., Selby, P. J., & Banks, R. E. (2014) · PROTEOMICS · doi:10.1002/pmic.201300553 · Cited by 429
Sample preparation and digestion for proteomic analyses using spin filters
Manza, L. L., Stamer, S. L., Ham, A. L., Codreanu, S. G., & Liebler, D. C. (2005) · PROTEOMICS · doi:10.1002/pmic.200401063 · Cited by 382
Erde, J., Loo, R. R. O., & Loo, J. A. (2014) · Journal of Proteome Research · doi:10.1021/pr4010019 · Cited by 331
Wiśniewski, J. R., & Mann, M. (2012) · Analytical Chemistry · doi:10.1021/ac300006b · Cited by 299
Feist, P., & Hummon, A. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16023537 · Cited by 288
Wiśniewski, J. R. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b00859 · Cited by 252
Ultra-deep and quantitative saliva proteome reveals dynamics of the oral microbiome
Grassl, N., Kulak, N. A., Pichler, G., Geyer, P. E., Jung, J., Schubert, S., Sinitcyn, P., Cox, J., & Mann, M. (2016) · Genome Medicine · doi:10.1186/s13073-016-0293-0 · Cited by 221
Cited by
Recent advances in mass spectrometry based clinical proteomics: applications to cancer research
Macklin, A., Khan, S., & Kislinger, T. (2020) · Clinical Proteomics · doi:10.1186/s12014-020-09283-w · Cited by 317
Automated sample preparation with SP 3 for low‐input clinical proteomics
Müller, T., Kalxdorf, M., Longuespée, R., Kazdal, D. N., Stenzinger, A., & Krijgsveld, J. (2020) · Molecular Systems Biology · doi:10.15252/msb.20199111 · Cited by 295
The E3 ligase adapter cereblon targets the C-terminal cyclic imide degron
Ichikawa, S., Flaxman, H. A., Xu, W., Vallavoju, N., Lloyd, H. C., Wang, B., Shen, D., Pratt, M. R., & Woo, C. M. (2022) · Nature · doi:10.1038/s41586-022-05333-5 · Cited by 195
X-linked ubiquitin-specific peptidase 11 increases tauopathy vulnerability in women
Yan, Y., Wang, X., Chaput, D., Shin, M.-K., Koh, Y., Gan, L., Pieper, A. A., Woo, J.-A. A., & Kang, D. E. (2022) · Cell · doi:10.1016/j.cell.2022.09.002 · Cited by 144
Zn-regulated GTPase metalloprotein activator 1 modulates vertebrate zinc homeostasis
Weiss, A., Murdoch, C. C., Edmonds, K. A., Jordan, M. R., Monteith, A. J., Perera, Y. R., Rodríguez Nassif, A. M., Petoletti, A. M., Beavers, W. N., Munneke, M. J., et al. (2022) · Cell · doi:10.1016/j.cell.2022.04.011 · Cited by 113
Metadata
- Authors
- HaileMariam, M., Eguez, R. V., Singh, H., Bekele, S., Ameni, G., Pieper, R., & Yu, Y.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-08-16
- Volume
- 17
- Issue
- 9
- Pages
- 2917-2924
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W2885193379
- Cited by
- 344
- References
- 29
- FWCI
- 8.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: S-Trap, an Ultrafast Sample-Preparation Approach for Shotgun Proteomics. https://app.cochat.ai/papers/10.1021/acs.jproteome.8b00505
- The paper
- HaileMariam, M., Eguez, R. V., Singh, H., Bekele, S., Ameni, G., Pieper, R., & Yu, Y. (2018). S-Trap, an Ultrafast Sample-Preparation Approach for Shotgun Proteomics. Journal of Proteome Research. https://doi.org/10.1021/acs.jproteome.8b00505
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.