The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Magnetic Particle Imaging: A Novel in Vivo Imaging Platform for Cancer Detection
Open accessAbstract
Cancer remains one of the leading causes of death worldwide. Biomedical imaging plays a crucial role in all phases of cancer management. Physicians often need to choose the ideal diagnostic imaging modality for each clinical presentation based on complex trade-offs among spatial resolution, sensitivity, contrast, access, cost, and safety. Magnetic particle imaging (MPI) is an emerging tracer imaging modality that detects superparamagnetic iron oxide (SPIO) nanoparticle tracer with high image contrast (zero tissue background signal), high sensitivity (200 nM Fe) with linear quantitation, and zero signal depth attenuation. MPI is also safe in that it uses safe, in some cases even clinically approved, tracers and no ionizing radiation. The superb contrast, sensitivity, safety, and ability to image anywhere in the body lends MPI great promise for cancer imaging. In this study, we show for the first time the use of MPI for in vivo cancer imaging with systemic tracer administration. Here, long circulating MPI-tailored SPIOs were created and administered intravenously in tumor bearing rats. The tumor was highlighted with tumor-to-background ratio of up to 50. The nanoparticle dynamics in the tumor was also well-appreciated, with initial wash-in on the tumor rim, peak uptake at 6 h, and eventual clearance beyond 48 h. Lastly, we demonstrate the quantitative nature of MPI through compartmental fitting in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gadolinium(III) Chelates as MRI Contrast Agents: Structure, Dynamics, and Applications
Caravan, P., Ellison, J. J., McMurry, T. J., & Lauffer, R. B. (1999) · Chemical Reviews · doi:10.1021/cr980440x · Cited by 4,483
Maeda, H. (2001) · Advances in Enzyme Regulation · doi:10.1016/s0065-2571(00)00013-3 · Cited by 2,495
Maeda, H., Nakamura, H., & Fang, J. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.10.002 · Cited by 2,376
Longmire, M., Choyke, P. L., & Kobayashi, H. (2008) · Nanomedicine · doi:10.2217/17435889.3.5.703 · Cited by 2,149
Tomographic imaging using the nonlinear response of magnetic particles
Gleich, B., & Weizenecker, J. (2005) · Nature · doi:10.1038/nature03808 · Cited by 2,003
Schenck, J. F. (1996) · Medical Physics · doi:10.1118/1.597854 · Cited by 1,522
Prabhakar, U., Maeda, H., Jain, R. K., Sevick-Muraca, E. M., Zamboni, W., Farokhzad, O. C., Barry, S. T., Gabizon, A., Grodzinski, P., & Blakey, D. C. (2013) · Cancer Research · doi:10.1158/0008-5472.can-12-4561 · Cited by 1,485
Kobayashi, H., Watanabe, R., & Choyke, P. L. (2014) · Theranostics · doi:10.7150/thno.7193 · Cited by 996
In vivo delivery, pharmacokinetics, biodistribution and toxicity of iron oxide nanoparticles
Arami, H., Khandhar, A., Liggitt, D., & Krishnan, K. M. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00541h · Cited by 830
Self-citationFass, L. (2008) · Molecular Oncology · doi:10.1016/j.molonc.2008.04.001 · Cited by 822
Cited by
Solving inverse problems using data-driven models
Arridge, S., Maass, P., Öktem, O., & Schönlieb, C.-B. (2019) · Acta Numerica · doi:10.1017/s0962492919000059 · Cited by 686
Tay, Z. W., Chandrasekharan, P., Chiu-Lam, A., Hensley, D. W., Dhavalikar, R., Zhou, X. Y., Yu, E. Y., Goodwill, P. W., Zheng, B., Rinaldi, C., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b00893 · Cited by 459
Advances in the Application of Magnetic Nanoparticles for Sensing
Gloag, L., Mehdipour, M., Chen, D., Tilley, R. D., & Gooding, J. J. (2019) · Advanced Materials · doi:10.1002/adma.201904385 · Cited by 364
Recent progress of magnetic nanoparticles in biomedical applications: A review
Anik, M. I., Hossain, M. K., Hossain, I., Mahfuz, A. M. U. B., Rahman, M. T., & Ahmed, I. (2021) · Nano Select · doi:10.1002/nano.202000162 · Cited by 300
Engineering applications of ferrofluids: A review
Kole, M., & Khandekar, S. (2021) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2021.168222 · Cited by 283
Surface design of magnetic nanoparticles for stimuli-responsive cancer imaging and therapy
Kang, T., Li, F., Baik, S., Shao, W., Ling, D., & Hyeon, T. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.05.013 · Cited by 280
Song, G., Kenney, M., Chen, Y.-S., Zheng, X., Deng, Y., Chen, Z., Wang, S. X., Gambhir, S. S., Dai, H., & Rao, J. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0506-0 · Cited by 262
Du, Y., Liu, X., Liang, Q., Liang, X.-J., & Tian, J. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b00630 · Cited by 260
Song, G., Chen, M., Zhang, Y., Cui, L., Qu, H., Zheng, X., Wintermark, M., Liu, Z., & Rao, J. (2018) · Nano Letters · doi:10.1021/acs.nanolett.7b03829 · Cited by 256
Metal–Phenolic Coatings as a Platform to Trigger Endosomal Escape of Nanoparticles
Chen, J., Li, J., Zhou, J., Lin, Z., Cavalieri, F., Czuba-Wojnilowicz, E., Hu, Y., Glab, A., Ju, Y., Richardson, J. J., et al. (2019) · ACS Nano · doi:10.1021/acsnano.9b05521 · Cited by 206
Universal cancer screening: revolutionary, rational, and realizable
Ahlquist, D. A. (2018) · npj Precision Oncology · doi:10.1038/s41698-018-0066-x · Cited by 135
Chiu-Lam, A., Staples, E., Pepine, C. J., & Rinaldi, C. (2021) · Science Advances · doi:10.1126/sciadv.abe3005 · Cited by 132
Magnetic Nanostructures: Rational Design and Fabrication Strategies toward Diverse Applications
Wang, S., Xu, J., Li, W., Sun, S., Gao, S., & Hou, Y. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00370 · Cited by 129
Improving nanotherapy delivery and action through image-guided systems pharmacology
Ng, T. S. C., Garlin, M. A., Weissleder, R., & Miller, M. A. (2020) · Theranostics · doi:10.7150/thno.37215 · Cited by 60
Recent Advances in the Development of Magnetic Nanoparticles for Biomedical Applications
Monteserín, M., Larumbe, S., Martínez, A. V., Burgui, S., & Francisco Martín, L. (2021) · Journal of Nanoscience and Nanotechnology · doi:10.1166/jnn.2021.19062 · Cited by 27
Ghaem, E. N., Dorranian, D., & Sari, A. H. (2021) · Optical and Quantum Electronics · doi:10.1007/s11082-020-02694-x · Cited by 17
Advancement of magnetic particle imaging in diagnosis and therapy
Harini, K., Girigoswami, K., Pallavi, P., Gowtham, P., Prabhu, A. D., & Girigoswami, A. (2024) · Advances in Natural Sciences: Nanoscience and Nanotechnology · doi:10.1088/2043-6262/ad3b7a · Cited by 8
Metadata
- Authors
- Yu, E. Y., Bishop, M., Zheng, B., Ferguson, R. M., Khandhar, A. P., Kemp, S. J., Krishnan, K. M., Goodwill, P. W., & Conolly, S. M.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-02-21
- Volume
- 17
- Issue
- 3
- Pages
- 1648-1654
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2588306107
- Cited by
- 366
- References
- 45
- FWCI
- 12.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.