CoChat

Injectable Nano Whitlockite Incorporated Chitosan Hydrogel for Effective Hemostasis

Muthiah Pillai, Nivedhitha Sundaram, Eswar, Kalyani, Amirthalingam, Sivashanmugam, Mony, Ullas, Kerala Varma, Praveen, Jayakumar, Rangasamy · 2019 · ACS Applied Bio Materials
Cited by 83

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Uncontrolled bleeding can lead to many complications that might cause multiple organ failures and even death. Of all the hemostatic agents used, chitosan has been reported to show better hemostatic potential. It acts through one mechanism involved in hemostasis that is plug formation by adhering to the injured site. Hence our focus is to enhance the hemostatic potential of chitosan (Ch) hydrogel by incorporating nano whitlockite (nWH: Ca 18 Mg 2 (HPO 4 ) 2 (PO 4 ) 12 ) that would release Ca 2+, Mg 2+, and PO 4 3– ions that would simultaneously initiate the coagulation cascade. Ch-nWH composite hydrogel can act simultaneously on different mechanisms involved in hemostasis and bring about rapid bleeding control. The nWH particles were synthesized using precipitation technique and were characterized. Particle size of nWH was found to be 75 ± 5 nm. Composite hydrogel was characterized using FTIR and XRD to confirm the presence of different constituents of the hydrogel. Rheological studies showed the shear-thinning property and increased elastic modulus of the composite hydrogel compared to Ch hydrogel. 2%Ch-4%nWH hydrogel was observed to be cytocompatible with Human Umbilical Vein Endothelial Cells (HUVEC). In the in vitro blood clotting analysis using citrated human whole blood, 2%Ch-4%nWH hydrogel showed rapid blood clot formation compared to control 2%Ch hydrogel. Further in vivo experiments performed on liver and femoral artery injuries created on Sprague–Dawley (S.D) rat model reveals that 2%Ch-4%nWH hydrogel promoted rapid bleeding control and less volume of blood loss compared to Ch hydrogel. These in vitro and in vivo results showed that incorporation of nWH has enhanced the hemostatic potential of Ch hydrogel. Therefore, the synthesized 2%Ch-4%nWH hydrogel may be a promising system that could bring about rapid hemostasis during life threatening bleeding.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsabm.8b00710

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Muthiah Pillai, N. S., Eswar, K., Amirthalingam, S., Mony, U., Kerala Varma, P., & Jayakumar, R.
Venue
ACS Applied Bio Materials
Published
2019-01-04
Volume
2
Issue
2
Pages
865-873
ISSN
2576-6422 (ISSN-L)
OpenAlex
W2907581037
Cited by
83
References
2
FWCI
5.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.