The DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index; 31 of the 53 sources its claims cite were checked for support.
Assessment of N95 and K95 respirator decontamination: fiber integrity, filtration efficiency, and dipole charge density
Open accessPreprint — published as 10.1021/acsami.0c17333 · Paper page
Abstract
Personal protective equipment (PPE) including N95 respirators are critical for persons exposed to SARS-CoV-2. KN95 respirators and N95 decontamination protocols have been described as solutions to a lack of such PPE. However, there are a few materials science studies that characterize the charge distribution and physical changes accompanying disinfection treatments particularly heating. Here, we report the filtration efficiency, dipole charge density, and fiber integrity of pristine N95 and KN95 respirators before and after various decontamination methods. We found that the filter layer of N95 is 8-fold thicker than that of KN95, which explains its 10% higher filtration efficiency (97.03 %) versus KN95 (87.76 %) under pristines condition. After 60 minutes of 70 °C treatment, the filtration efficiency and dipole charge density of N95 became 97.16% and 12.48 μC/m 2 , while those of KN95 were 83.64% and 1.48 μC/m 2 ; moreover, fit factor of N95 was 55 and that of KN95 was 2.7. In conclusion, the KN95 respirator is an inferior alternative of N95 respirator. In both systems, a loss of electrostatic charge does not directly correlate to a decrease in performance.
Overview
CoChat Summary
TL;DR
This study compares N95 and KN95 respirators before and after dry-heat decontamination, measuring filtration efficiency, dipole charge density, fit factor, and fiber integrity. It concludes that KN95 is an inferior alternative to N95, with lower filtration efficiency, fit factor, and dipole charge density, and that loss of electrostatic charge did not directly correlate with filtration performance.
Key findings
- Pristine N95 had 97.03% filtration efficiency versus 87.76% for KN95; the N95 filter layer was 8-fold thicker than the KN95 filter layer, which the authors say explains the roughly 10% filtration gap.
- The abstract reports that after 60 minutes of 70°C treatment, N95 filtration efficiency and dipole charge density were 97.16% and 12.48 μC/m², while KN95 values were 83.64% and 1.48 μC/m²; fit factor was 55 for N95 and 2.7 for KN95.
- Dipole charge density decreased with heat treatment: N95 fell from 38.82 μC/m² pristine to 12.48 μC/m² after 30 minutes at 70°C (67% drop), and KN95 fell from 4.6 to 2.27 μC/m² (50% drop) after 30 minutes. Despite charge loss, filtration changed little; removing all dipole charge with isopropanol reduced N95 filtration efficiency from 97.03% to 94.24%.
- At 150°C as a positive control, N95 inner spun-bond PP melted at fiber intersections; KN95 showed outer-layer fracture and balloon-shaped cotton fiber expansions, while the melt-blown PP filter layers of both respirators resisted damage.
Methods
- N95 (3M 1860) and KN95 (Yomasi) respirators were cut into 2 cm squares and heat-treated in a thermostat-controlled oven at 70°C for three 30-minute cycles, with 150°C as a positive control; VHP-sterilized N95s (3M 1860, 3M 1870, 3M 8210) were also tested.
- Filtration efficiency and fit factor were measured with a PortaCount Plus Model 8020; material filtration used a 2 cm chamber, and fit factor used a probe while an individual wore the respirator in a closed room with two lit candles. SEM (FEI Apreo, 1 kV, 0.10 nA) assessed fiber morphology; dipole charge density was measured with a Trek model 344 electrostatic voltmeter; IPA dipping removed charges.
- Error bars represent standard deviations of 5 measurements; fiber diameters were calculated with ImageJ.
Limitations
- The paper does not include a dedicated limitations section. The text itself is a medRxiv preprint marked “not certified by peer review.”
- Evident limitations from the text: most comparisons use one N95 model (3M 1860) and one KN95 model (Yomasi), so findings may not generalize; fit factor was measured in a closed room with lit candles rather than real-world use; the study does not directly test viral inactivation, relying on cited validation of 70°C; and the authors note no quantitative relationship between dipole charge density and filtration efficiency.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
18 Valid · 7 Not valid · 15 Not checked · 56 Own results and interpretations
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“The ethanol method is found to damage N95 respirators after first cycle of decontamination”
What the sources say
- Disputedcites [23] Fischer, R. J. ; Morris, D. H. ; van Doremalen, N. ; Sarchette, S. ; Matson, M. J. ; Bushmaker, T. ; Yinda, C. K. ; Seifert, S. N. ; Gamble, A. ; Williamson, B. N. Effectiveness of N95 Respirator Decontamination and Reuse against SARS-CoV-2 Virus. Emerging Infectious Diseases 2020, 26 (9). sourceExperimental — accuracy not yet measured
The paper’s results passage says N95 filtration performance was not markedly reduced after a single decontamination with any method. It reports sharp drops for ethanol-treated masks only after subsequent rounds, contrary to the claim’s first-cycle timing. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
Some cited sources support this claim and some don’t — read each source’s verdict below.
In the paper
“Recent works 7, 23, 26-29 focused nearly exclusively on the performance of the respirators, i.e., their filtration performance.”
What the sources say
- Not checked — no full text of the sourcecites [7] 2020, Aerosol filtration efficiency of common fabrics used in respiratory cloth masks, ACS nano source
- Disputedcites [23] Fischer, R. J. ; Morris, D. H. ; van Doremalen, N. ; Sarchette, S. ; Matson, M. J. ; Bushmaker, T. ; Yinda, C. K. ; Seifert, S. N. ; Gamble, A. ; Williamson, B. N. Effectiveness of N95 Respirator Decontamination and Reuse against SARS-CoV-2 Virus. Emerging Infectious Diseases 2020, 26 (9). sourceExperimental — accuracy not yet measured
The paper’s Abstract states that it analyzed both SARS-CoV-2 decontamination effectiveness and respirator function. Its methods description reports measuring viral inactivation as well as filtration performance, contrary to the claim that this work focused nearly exclusively on filtration. (LLM, conf=0.86)
Checked by a reasoning model — may be wrong.
- Disputedcites [26] Xiang, Y. ; Song, Q. ; Gu, W. Decontamination of Surgical Face Masks and N95 Respirators by Dry Heat Pasteurization for One Hour at 70° C. American Journal of Infection Control 2020. sourceExperimental — accuracy not yet measured
The Results (page unavailable) report that dry heat killed seven types of bacteria and inactivated H1N1, as well as reporting filtration efficiency. The Methods also describe fit testing. This paper therefore did not focus nearly exclusively on respirator filtration performance. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
- Supportedcites [27] Liao, L. ; Xiao, W. ; Zhao, M. ; Yu, X. ; Wang, H. ; Wang, Q. ; Chu, S. ; Cui, Y. Can N95 respirators be reused after disinfection? How many times? ACS nano 2020. source
The Abstract reports filtration efficiency across repeated disinfection cycles, and Sample preparation describes filtration testing of fabrics and respirators. The paper also considers pressure drop and cautions about fit, but its experimental focus supports the characterization as nearly, rather than entirely, focused on filtration performance. The indexed passages provide no page numbers. (LLM, conf=0.87)
- Disputedcites [28] Juang, P. S. ; Tsai, P. N95 Respirator Cleaning and Reuse Methods Proposed by the Inventor of the N95 Mask Material. Journal of Emergency Medicine 2020. sourceExperimental — accuracy not yet measured
The Introduction reports filtration-efficiency figures, but the section on cleaning and reuse also discusses evidence for viral survival and inactivation on N95 masks. This paper therefore does not focus nearly exclusively on filtration performance. The indexed copy provides section labels but no page numbers. (LLM, conf=0.84)
Checked by a reasoning model — may be wrong.
- Supportedcites [29] 2020, Effects of Sterilization With Hydrogen Peroxide and Chlorine Dioxide on the Filtration Efficiency of N95, KN95, and Surgical Face Masks, JAMA Network Open source
The Methods section describes the study as a comparison of sterilization effects on mask filtration efficiency. The Results and Discussion focus on overall and particle-size-specific filtration efficiency; pressure drop was also measured, consistent with the claim’s “nearly exclusively” qualifier. (LLM, conf=0.90)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
Every source the paper cites for this claim was checked and supports it.
In the paper
“Due to electrostatic interactions between dusts and fabrics, 33 plenty of small particles were trapped on the spun-bond PP fibers of the outer layer ( Figure 2A and Figure 2D ).”
What the sources say
- Supportedcites [33] 1980, electrostatics, and filtration: A review of new technology, Journal of the Air Pollution Control Association source
The cited paper’s “Electrostatic Capture of Fine Particles by Fiber Beds” section reports efficient collection of submicron charged particles on fibers. Its “Mechanisms for Electrostatic Enhancement of Fabric Filter Performance” section also describes electrostatic attraction between particles and collectors. These passages support the cited explanation; the spun-bond PP outer-layer observation is presented as the citing paper’s own figure-based result. (LLM, conf=0.90)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“and UV-radiation has limited penetration through the multiple layers of the respirator. 23”
What the sources say
- Partly supportedcites [23] Fischer, R. J. ; Morris, D. H. ; van Doremalen, N. ; Sarchette, S. ; Matson, M. J. ; Bushmaker, T. ; Yinda, C. K. ; Seifert, S. N. ; Gamble, A. ; Williamson, B. N. Effectiveness of N95 Respirator Decontamination and Reuse against SARS-CoV-2 Virus. Emerging Infectious Diseases 2020, 26 (9). sourceExperimental — accuracy not yet measured
The paper’s Abstract (page not provided) reports that UV light inactivated SARS-CoV-2 more slowly on N95 fabric than on steel, probably because the fabric is porous. It does not specifically state that UV radiation has limited penetration through the respirator’s multiple layers. (LLM, conf=0.83)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Contaminated N95 and KN95 respirator were put in the oven at 70 ° C which can inactivate SARSCoV-2. 23, 32”
What the sources say
- Supportedcites [23] Fischer, R. J. ; Morris, D. H. ; van Doremalen, N. ; Sarchette, S. ; Matson, M. J. ; Bushmaker, T. ; Yinda, C. K. ; Seifert, S. N. ; Gamble, A. ; Williamson, B. N. Effectiveness of N95 Respirator Decontamination and Reuse against SARS-CoV-2 Virus. Emerging Infectious Diseases 2020, 26 (9). source
The paper’s decontamination findings state that dry heat at 70°C killed SARS-CoV-2, with a speed similar to UV light. It cautions that treatment must last long enough to achieve sufficient reduction; it does not establish a duration for the oven treatment described in the citing sentence. (LLM, conf=0.94)
- Supportedcites [32] Chin, A. ; Chu, J. ; Perera, M. ; Hui, K. ; Yen, H.-L. ; Chan, M. ; Peiris, M. ; Poon, L. Stability of SARS-CoV-2 in different environmental conditions. medRxiv 2020. source
The paper’s temperature-stability section reports that SARS-CoV-2 in virus transport medium was inactivated after five minutes at 70°C. This supports the attributed claim that 70°C can inactivate the virus. (LLM, conf=0.93)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
46 more claims · 6 with their cited sources checked
Create a free account to see all 96 claims and to verify the 4 references still open.
- Probably not a substantial claim. 24
- It may state two separate claims as one. 32
- The quote only partly states this claim. 1
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ Conclusion · p. 10
“Compared to the initial conditions, the filtration efficiencies of KN95 and N95 respirators increased after heat treatments”
§ Abstract · p. 1
“KN95 (87.76 %) under pristines condition. After 60 minutes of 70 °C treatment, the filtration efficiency and dipole charge density of N95 became 97.16% and 12.48 μC/m 2 , while those of KN95 were 83.64% and 1.48 μC/m 2”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Comparison of N95 and KN95 respirator · p. 8
“It dropped by 67 percent (12.48 μC/m 2 ) after 30 minutes of 70 ºC treatment.”
§ Comparison of N95 and KN95 respirator · p. 8
“The dipole charge was 12.48 μC/m 2 after 60 minutes of 70 ºC treatment ( Figure 3E ).”
Citations
Cites
Structural basis for the recognition of SARS-CoV-2 by full-length human ACE2
Yan, R., Zhang, Y., Li, Y., Xia, L., Guo, Y., & Zhou, Q. (2020) · Science · doi:10.1126/science.abb2762 · Cited by 5,040
Ranney, M. L., Griffeth, V., & Jha, A. K. (2020) · New England Journal of Medicine · doi:10.1056/nejmp2006141 · Cited by 2,018
Stability of SARS-CoV-2 in different environmental conditions
Chin, A. W. H., Chu, J. T. S., Perera, M. R. A., Hui, K. P. Y., Yen, H.-L., Chan, M. C. W., Peiris, M., & Poon, L. L. M. (2020) · doi:10.1101/2020.03.15.20036673 · Cited by 1,948
Stability of SARS-CoV-2 in different environmental conditions
Chin, A. W. H., Chu, J. T. S., Perera, M. R. A., Hui, K. P. Y., Yen, H.-L., Chan, M. C. W., Peiris, M., & Poon, L. L. M. (2020) · The Lancet Microbe · doi:10.1016/s2666-5247(20)30003-3 · Cited by 1,946
Airborne transmission of SARS-CoV-2: The world should face the reality
Morawska, L., & Cao, J. (2020) · Environment International · doi:10.1016/j.envint.2020.105730 · Cited by 1,728
Real estimates of mortality following COVID-19 infection
Baud, D., Qi, X., Nielsen-Saines, K., Musso, D., Pomar, L., & Favre, G. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30195-x · Cited by 1,253
Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., & Katoshevski, D. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.11.002 · Cited by 1,129
Chao, C. Y. H., Wan, M. P., Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Li, Y., Xie, X., et al. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.10.003 · Cited by 1,087
Aerosol filtration efficiency of common fabrics used in respiratory cloth masks
Konda, A., Prakash, A., Moss, G. A., Schmoldt, M., Grant, G. D., & Guha, S. (2020) · ACS Nano · doi:10.1021/acsnano.0c03252 · Cited by 934
Reducing transmission of SARS-CoV-2
Prather, K. A., Wang, C. C., & Schooley, R. T. (2020) · Science · doi:10.1126/science.abc6197 · Cited by 850
Cited by
Derraik, J. G. B., Anderson, W. A., Connelly, E. A., & Anderson, Y. C. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17176117 · Cited by 140
“In addition, as reported for UGVI treatment, some FFRs failed fit or particle filtration testing even before treatment [92,95,97], and the ability of different models to withstand high-temperature insults varied [88].”
BackgroundOutcomes from COVID-19 across the range of frailty: excess mortality in fitter older people
Miles, A., Webb, T. E., Mcloughlin, B. C., Mannan, I., Rather, A., Knopp, P., & Davis, D. H. J. (2020) · European Geriatric Medicine · doi:10.1007/s41999-020-00354-7 · Cited by 77
Ogbuoji, E. A., Zaky, A. M., & Escobar, I. C. (2021) · Polymers · doi:10.3390/polym13121998 · Cited by 53
“PP has a high chemical (acid and alkali) resistance and can withstand elevated temperatures up to 150 ◦C [95].”
BackgroundWibisono, Y., Fadila, C. R., Saiful, S., & Bilad, M. R. (2020) · Polymers · doi:10.3390/polym12112516 · Cited by 53
“The typical thickness of the outer, filter, and inner layers are 300–400, 800–1200 and 100–150 μm, respectively [14].”
BackgroundDecontamination of N95 respirators against SARS-CoV-2: A scoping review
Sarkis‐Onofre, R., Borges, R. D. C., Demarco, G. T., Dotto, L., Schwendicke, F., & Demarco, F. F. (2020) · Journal of Dentistry · doi:10.1016/j.jdent.2020.103534 · Cited by 28
“…either moist heat (82 oC + 62− 66% RH) or vaporous hydrogen peroxide can address the hospital’s needs; however, each approach has notable limitations Yim et al. 2020 Authors reported the filtration efficiency, dipole charge density, and fiber integrity of pristine N95 and KN95 respirators before…”
Metadata
- Authors
- Yim, W., Cheng, D., Patel, S., Kui, R., Meng, Y. S., & Jokerst, J. V.
- Affiliations
- University of California San Diego (US)
- Corresponding author
- Jokerst, Jesse V.
- Venue
- medRxiv
- Publisher
- openRxiv
- Published
- 2020-07-09
- Volume
- 12
- Issue
- 49
- Pages
- 54473-54480
- ISSN
- 1944-8244 (ISSN-L)
- PMC
- PMC7359546
- OpenAlex
- W3107154450
- Semantic Scholar
- ec447e67764e75ae735856f3c49fc638831a3086
- Cited by
- 104
- References
- 0
- Citations by year
- 2026: 5 · 2025: 8 · 2024: 11 · 2023: 22 · 2022: 23 · 2021: 28 · 2020: 7
- FWCI
- 6.88
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Locations
- ACS Applied Materials & Interfaces (publishedVersion)
- medRxiv (submittedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- PubMed Central (submittedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Funders
- National Science Foundation (1845683, HL137187)
- Tobacco-Related Disease Research Program
- University of California (R00RG2515)
- National Institutes of Health (COVID-19)
- National Institute on Aging (R21AG065776)
- National Heart, Lung, and Blood Institute (DP2HL137187)
- National Institute of Allergy and Infectious Diseases (R21AI157957)
- Division of Materials Research (1845683)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Materials Science › Polymers and Plastics › Textile materials and evaluations
- Keywords
- N95 respirators, respirator decontamination, filtration efficiency, static electricity, heat disinfection, emergency use authorization, personal protective equipment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of N95 and K95 respirator decontamination: fiber integrity, filtration efficiency, and dipole charge density. https://app.cochat.ai/papers/10.1101/2020.07.07.20148551
- The paper
- Yim, W., Cheng, D., Patel, S., Kui, R., Meng, Y. S., & Jokerst, J. V. (2020). Assessment of N95 and K95 respirator decontamination: fiber integrity, filtration efficiency, and dipole charge density. medRxiv. https://doi.org/10.1101/2020.07.07.20148551
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.