Improved Selectivity and Sensitivity of Gas Sensing Using a 3D Reduced Graphene Oxide Hydrogel with an Integrated Microheater
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Low-cost, one-step, and hydrothermal synthesized 3D reduced graphene oxide hydrogel (RGOH) is exploited to fabricate a high performance NO2 and NH3 sensor with an integrated microheater. The sensor can experimentally detect NO2 and NH3 at low concentrations of 200 ppb and 20 ppm, respectively, at room temperature. In addition to accelerating the signal recovery rate by elevating the local silicon substrate temperature, the microheater is exploited for the first time to improve the selectivity of NO2 sensing. Specifically, the sensor response from NH3 can be effectively suppressed by a locally increased temperature, while the sensitivity of detecting NO2 is not significantly affected. This leads to good discrimination between NO2 and NH3. This strategy paves a new avenue to improve the selectivity of gas sensing by using the microheater to raise substrate temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Self-Assembled Graphene Hydrogel via a One-Step Hydrothermal Process
Xu, Y., Sheng, K., Li, C., & Shi, G. (2010) · ACS Nano · doi:10.1021/nn101187z · Cited by 3,251
Cited by
Flexible Graphene-Based Wearable Gas and Chemical Sensors
Singh, E., Meyyappan, M., & Nalwa, H. S. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b07063 · Cited by 776
Sang, M., Shin, J., Kim, K., & Yu, K. J. (2019) · Nanomaterials · doi:10.3390/nano9030374 · Cited by 505
Selectivity in Chemiresistive Gas Sensors: Strategies and Challenges
Bulemo, P. M., Kim, D.-H., Shin, H., Cho, H.-J., Koo, W.-T., Choi, S.-J., Park, C., Ahn, J., Güntner, A. T., Penner, R. M., et al. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00592 · Cited by 418
Recent advances in carbon material-based NO2 gas sensors
Lee, S. W., Lee, W., Hong, Y., Lee, G., & Yoon, D. S. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.08.203 · Cited by 304
Recent Advances in Sensing Applications of Graphene Assemblies and Their Composites
Tung, T. T., Nine, M. J., Krebsz, M., Pasinszki, T., Coghlan, C. J., Tran, D. N. H., & Losic, D. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201702891 · Cited by 294
Carbon Nanocoil-Based Fast-Response and Flexible Humidity Sensor for Multifunctional Applications
Wu, J., Sun, Y.-M., Wu, Z., Li, X., Wang, N., Tao, K., & Wang, G. P. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b18599 · Cited by 264
Self-citationFunctionalized Hydrogel-Based Wearable Gas and Humidity Sensors.
Luo, Y., Li, J., Ding, Q., Wang, H., Liu, C., & Wu, J. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01109-2 · Cited by 236
“Reduced graphene oxide hydrogel (RGOH) is synthesized from graphene oxide using a one-pot hydrothermal self-assembly method by Wu et al. [135].”
MethodSelf-citationWu, J., Wu, Z., Han, S., Yang, B.-R., Gui, X., Tao, K., Liu, C., Miao, J., & Norford, L. K. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b17437 · Cited by 225
Self-citationA 3D Chemically Modified Graphene Hydrogel for Fast, Highly Sensitive, and Selective Gas Sensor
Wu, J., Tao, K., Guo, Y., Li, Z., Wang, X., Luo, Z., Feng, S., Du, C., Chen, D., Miao, J., et al. (2017) · Advanced Science · doi:10.1002/advs.201600319 · Cited by 184
Self-citationMogul‐Patterned Elastomeric Substrate for Stretchable Electronics
Lee, H., Bae, C., Duy, L. T., Sohn, I., Kim, D., Song, Y., Kim, Y., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201505218 · Cited by 130
Chemically functionalized 3D graphene hydrogel for high performance gas sensing
Wu, J., Tao, K., Zhang, J., Guo, Y., Miao, J., & Norford, L. K. (2016) · Journal of Materials Chemistry A · doi:10.1039/c6ta01426g · Cited by 117
Self-citationHydrogel-Based Gas Sensors for NO 2 and NH 3
Zhi, H., Gao, J., & Feng, L. (2020) · ACS Sensors · doi:10.1021/acssensors.9b02383 · Cited by 108
Wu, J., Wu, Z., Ding, H., Wei, Y., Huang, W., Yang, X., Li, Z., Qiu, L., & Wang, X. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b18098 · Cited by 104
Self-citationWu, J., Wei, Y., Ding, H., Wu, Z., Yang, X., Li, Z., Huang, W., Xie, X., Tao, K., & Wang, X. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c00578 · Cited by 86
Self-citation
Metadata
- Authors
- Wu, J., Tao, K., Miao, J., & Norford, L. K.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-12-02
- Volume
- 7
- Issue
- 49
- Pages
- 27502-27510
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2289289769
- Cited by
- 154
- References
- 1
- FWCI
- 8.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.