The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Sulfone-Rhodamines: A New Class of Near-Infrared Fluorescent Dyes for Bioimaging
Abstract
Given the wavelength dependence of tissue transparency and the requirement for sufficiently low background autofluorescence, the development of fluorescent dyes with excitation and emission maxima beyond 700 nm is highly desired, but it is a challenging task. Herein, a new class of fluorescent dyes, named sulfone-rhodamines (SO2Rs), was developed on the basis of the one-atom replacement of the rhodamine 10-position O atom by a sulfone group. Such a modification makes their absorption and emission maxima surprisingly reach up to 700-710 and 728-752 nm, respectively, much longer than their O-, C-, and Si-rhodamine analogs, due to the unusual d*-π* conjugation. Among these dyes, SO2R4 and SO2R5, bearing disubstituted meso-phenyl groups, show the greatest potentials for bioimaging applications in view of their wide pH range of application, high photostability, and big extinction coefficients and fluorescence quantum yields. They could quickly penetrate cells to give stable NIR fluorescence, even after continuous irradiation by a semiconductor laser, making them suitable candidates for time-lapse and long-term bioimaging applications. Moreover, they could specifically localize in lysosomes independent of alkylmorpholine targeted group, thus avoiding the problematic alkalization effect suffered by most LysoTrackers. Further imaging assays of frozen slices of rat kidney reveal that their tissue imaging depth is suprior to the widely used NIR labeling agent Cy5.5.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A clearer vision for in vivo imaging
Weissleder, R. (2001) · Nature Biotechnology · doi:10.1038/86684 · Cited by 3,839
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
Self-citation
Cited by
Hybrid Rhodamine Fluorophores in the Visible/NIR Region for Biological Imaging
Wang, L., Du, W., Hu, Z., Uvdal, K., Li, L., & Huang, W. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201901061 · Cited by 348
Cheng, D., Peng, J., Lv, Y., Su, D., Liu, D., Chen, M., Yuan, L., & Zhang, X. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b01374 · Cited by 308
A general method to optimize and functionalize red-shifted rhodamine dyes
Grimm, J. B., Tkachuk, A. N., Xie, L., Choi, H., Mohar, B., Falco, N., Schaefer, K., Patel, R., Zheng, Q., Liu, Z., et al. (2020) · Nature Methods · doi:10.1038/s41592-020-0909-6 · Cited by 298
Cyclometalated iridium(III) complexes for life science
Caporale, C., & Massi, M. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2018.02.006 · Cited by 258
Xanthene-Based NIR-II Dyes for In Vivo Dynamic Imaging of Blood Circulation
Liu, D., He, Z., Zhao, Y., Yang, Y., Shi, W., Li, X., & Ma, H. (2021) · Journal of the American Chemical Society · doi:10.1021/jacs.1c07711 · Cited by 217
Metadata
- Authors
- Liu, J., Sun, Y.-Q., Zhang, H., Shi, H., Shi, Y., & Guo, W.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-08-26
- Volume
- 8
- Issue
- 35
- Pages
- 22953-22962
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2511865812
- Cited by
- 185
- References
- 2
- FWCI
- 7.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sulfone-Rhodamines: A New Class of Near-Infrared Fluorescent Dyes for Bioimaging. https://app.cochat.ai/papers/10.1021/acsami.6b08338
- The paper
- Liu, J., Sun, Y.-Q., Zhang, H., Shi, H., Shi, Y., & Guo, W. (2016). Sulfone-Rhodamines: A New Class of Near-Infrared Fluorescent Dyes for Bioimaging. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.6b08338
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.