The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
An All-Silk-Derived Dual-Mode E-skin for Simultaneous Temperature–Pressure Detection
Abstract
Flexible skin-mimicking electronics are highly desired for development of smart human-machine interfaces and wearable human-health monitors. Human skins are able to simultaneously detect different information, such as touch, friction, temperature, and humidity. However, due to the mutual interferences of sensors with different functions, it is still a big challenge to fabricate multifunctional electronic skins (E-skins). Herein, a combo temperature-pressure E-skin is reported through assembling a temperature sensor and a strain sensor in both of which flexible and transparent silk-nanofiber-derived carbon fiber membranes (SilkCFM) are used as the active material. The temperature sensor presents high temperature sensitivity of 0.81% per centigrade. The strain sensor shows an extremely high sensitivity with a gauge factor of ∼8350 at 50% strain, enabling the detection of subtle pressure stimuli that induce local strain. Importantly, the structure of the SilkCFM in each sensor is designed to be passive to other stimuli, enabling the integrated E-skin to precisely detect temperature and pressure at the same time. It is demonstrated that the E-skin can detect and distinguish exhaling, finger pressing, and spatial distribution of temperature and pressure, which cannot be realized using single mode sensors. The remarkable performance of the silk-based combo temperature-pressure sensor, together with its green and large-scalable fabrication process, promising its applications in human-machine interfaces and soft electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hou, J., Cao, C., Idrees, F., & Ma, X. (2015) · ACS Nano · doi:10.1021/nn506394r · Cited by 1,529
Stretchable silicon nanoribbon electronics for skin prosthesis
Kim, J., Lee, M., Shim, H. J., Ghaffari, R., Cho, H. R., Son, D., Jung, Y. H., Soh, M., Choi, C., Jung, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms6747 · Cited by 1,435
Ultrathin conformal devices for precise and continuous thermal characterization of human skin
Webb, R. C., Bonifas, A. P., Behnaz, A., Zhang, Y., Yu, K. J., Cheng, H., Shi, M., Bian, Z., Liu, Z., Kim, Y.-S., et al. (2013) · Nature Materials · doi:10.1038/nmat3755 · Cited by 1,229
Self-citationTrung, T. Q., Ramasundaram, S., Hwang, B., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504441 · Cited by 870
Zhang, F., Zang, Y., Huang, D., Di, C.-A., & Zhu, D. (2015) · Nature Communications · doi:10.1038/ncomms9356 · Cited by 668
A Flexible Bimodal Sensor Array for Simultaneous Sensing of Pressure and Temperature
Tien, N. T., Jeon, S., Kim, D., Trung, T. Q., Jang, M., Hwang, B., Byun, K., Bae, J., Lee, E., Tok, J. B. ‐., et al. (2014) · Advanced Materials · doi:10.1002/adma.201302869 · Cited by 438
Stretchable Graphene Thermistor with Tunable Thermal Index
Yan, C., Wang, J., & Lee, P. S. (2015) · ACS Nano · doi:10.1021/nn507441c · Cited by 359
Harada, S., Kanao, K., Yamamoto, Y., Arie, T., Akita, S., & Takei, K. (2014) · ACS Nano · doi:10.1021/nn506293y · Cited by 350
Carbonization of a stable β-sheet-rich silk protein into a pseudographitic pyroprotein
Cho, S. Y., Yun, Y. S., Lee, S., Jang, D., Park, K.-Y., Kim, J. K., Kim, B. H., Kang, K., Kaplan, D. L., & Jin, H.-J. (2015) · Nature Communications · doi:10.1038/ncomms8145 · Cited by 277
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Advanced Carbon for Flexible and Wearable Electronics
Wang, C., Xia, K., Wang, H., Liang, X., Yin, Z., & Zhang, Y. (2019) · Advanced Materials · doi:10.1002/adma.201801072 · Cited by 1,300
Self-citationSignificance of Nanomaterials in Wearables: A Review on Wearable Actuators and Sensors
Jayathilaka, W. A. D. M., Qi, K., Qin, Y., Chinnappan, A., Serrano‐García, W., Baskar, C., Wang, H., He, J., Cui, S., Thomas, S. W., et al. (2019) · Advanced Materials · doi:10.1002/adma.201805921 · Cited by 627
Multifunctional Skin‐Inspired Flexible Sensor Systems for Wearable Electronics
Xu, K., Lu, Y., & Takei, K. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201800628 · Cited by 602
Natural Biopolymer-Based Biocompatible Conductors for Stretchable Bioelectronics
Wang, C., Yokota, T., & Someya, T. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00897 · Cited by 412
Self-citation
Metadata
- Authors
- Wang, C., Xia, K., Zhang, M., Jian, M., & Zhang, Y.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-11-03
- Volume
- 9
- Issue
- 45
- Pages
- 39484-39492
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2766331206
- Cited by
- 277
- References
- 9
- FWCI
- 8.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An All-Silk-Derived Dual-Mode E-skin for Simultaneous Temperature–Pressure Detection. https://app.cochat.ai/papers/10.1021/acsami.7b13356
- The paper
- Wang, C., Xia, K., Zhang, M., Jian, M., & Zhang, Y. (2017). An All-Silk-Derived Dual-Mode E-skin for Simultaneous Temperature–Pressure Detection. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.7b13356
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.