The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Highly Stretchable and Sensitive Strain Sensor with Porous Segregated Conductive Network
Abstract
Flexible strain sensors based on elastomeric conductive polymer composites (ECPCs) play an important role in wearable sensing electronics. However, the achievement of good conjunction between broad detection range and high sensitivity is still challenging. Herein, a highly stretchable and sensitive strain sensor was developed with the formation of porous segregated conductive network in the carbon nanotube/thermoplastic polyurethane composite via a facile and nontoxic compression-molding plus salt-leaching method. The strain sensor with porous segregated conductive network exhibited perfect combination of ultrawide sensing range (800% strain), large sensitivity (gauge factor of 356.4), short response time (180 ms) and recovery time (180 ms), as well as superior stability and durability. The integrated porous structure intensifies the deformation of segregated conductive network when tension strain is applied, which benefits enhancement of the sensitivity. Our sensor could monitor not only subtle oscillation and physiological signals but also energetic human motions efficiently, revealing promising potential applications in wearable motion monitoring systems. This work provides a unique and effective strategy for realizing ECPCs based strain sensors with excellent comprehensive sensing performances.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review
Amjadi, M., Kyung, K., Park, I., & Sitti, M. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504755 · Cited by 3,202
Cai, G., Wang, J., Qian, K., Chen, J., Li, S., & Lee, P. S. (2017) · Advanced Science · doi:10.1002/advs.201600190 · Cited by 921
Park, J., Lee, Y., Hong, J., Lee, Y., Ha, M., Jung, Y., Lim, H., Kim, S. Y., & Ko, H. (2014) · ACS Nano · doi:10.1021/nn505953t · Cited by 649
Recent Progress on Stretchable Electronic Devices with Intrinsically Stretchable Components
Trung, T. Q., & Lee, N. (2017) · Advanced Materials · doi:10.1002/adma.201603167 · Cited by 497
Cited by
The emergence of AI-based wearable sensors for digital health technology: a review
Shajari, S., Kuruvinashetti, K., Komeili, A., & Sundararaj, U. (2023) · Sensors · doi:10.3390/s23239498 · Cited by 535
He, Y., Wu, D., Zhou, M., Zheng, Y., Wang, T., Lu, C., Zhang, L., Liu, H., & Liu, C. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c22823 · Cited by 284
Hao, S., Shao, C., Meng, L., Cui, C., Xu, F., & Yang, J. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c18250 · Cited by 258
A flexible wearable strain sensor for human-motion detection and a human–machine interface
Zhang, H., Zhang, D., Guan, J., Wang, D., Tang, M., Ma, Y., & Xia, H. (2022) · Journal of Materials Chemistry C · doi:10.1039/d2tc03147g · Cited by 97
Metadata
- Authors
- Zhou, C.-G., Sun, W.-J., Jia, L.-C., Xu, L., Dai, K., Yan, D.-X., & Li, Z.-M.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-09-12
- Volume
- 11
- Issue
- 40
- Pages
- 37094-37102
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2973044475
- Cited by
- 161
- References
- 4
- FWCI
- 6.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Stretchable and Sensitive Strain Sensor with Porous Segregated Conductive Network. https://app.cochat.ai/papers/10.1021/acsami.9b12504
- The paper
- Zhou, C.-G., Sun, W.-J., Jia, L.-C., Xu, L., Dai, K., Yan, D.-X., & Li, Z.-M. (2019). Highly Stretchable and Sensitive Strain Sensor with Porous Segregated Conductive Network. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.9b12504
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.