Electrochemical Biosensors for Detection of Pesticides and Heavy Metal Toxicants in Water: Recent Trends and Progress
Open accessThe DOI matches its Crossref record; 105 of the 105 references it cites were found in a registry or an index.
Abstract
The release of chemicals into water systems has resulted in pollution in many parts of the world, threatening human health and aquatic ecosystems. Sources of chemical discharge include industry, agricultural, wastewater treatment plants, and stormwater overflows. To combat water pollution, the European Union has introduced several directives that set concentration limits for chemicals in drinking water, surface water, and groundwater. To meet these limits, it is essential that rapid, reliable, and sensitive analytical detection systems be developed and put into use. This Review presents the progress made in the development of electrochemical biosensors for environmental toxicants (pesticides and heavy metals) over the past seven years (2014–2020). For those unfamiliar with this field of research, the concept of a biosensor is introduced followed by a critical evaluation of their performance in detecting the toxicants. Current challenges are discussed as well as potential avenues for future research, including the demands for enhanced analytical performance, improved biosensor stability and shelf life, and greater integration with microfluidic devices and wireless database technologies for remote environmental sensing applications. We believe that this Review will be beneficial and enhance awareness and appreciation of the role that electrochemical biosensors can play in protecting our environment and water resources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heberer, T. (2002) · Toxicology Letters · doi:10.1016/s0378-4274(02)00041-3 · Cited by 2,995
Ronkainen, N. J., Halsall, H. B., & Heineman, W. R. (2010) · Chemical Society Reviews · doi:10.1039/b714449k · Cited by 1,945
Treatment technologies for emerging contaminants in water: A review
Rodriguez-Narvaez, O. M., Peralta-Hernandez, J. M., Goonetilleke, A., & Bandala, E. R. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.04.106 · Cited by 1,199
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
A review on detection of heavy metal ions in water—An electrochemical approach
Gumpu, M. B., Sethuraman, S., Krishnan, U. M., & Rayappan, J. B. B. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.02.122 · Cited by 1,027
Wongkaew, N., Simsek, M., Griesche, C., & Baeumner, A. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00172 · Cited by 657
Electrochemical immunosensors – A powerful tool for analytical applications
Felix, F. S., & Angnes, L. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.11.029 · Cited by 599
Luka, G., Ahmadi, A., Najjaran, H., Alocilja, E., DeRosa, M., Wolthers, K., Malki, A., Aziz, H., Althani, A., & Hoorfar, M. (2015) · Sensors · doi:10.3390/s151229783 · Cited by 566
Quesada, H. B., Baptista, A. T. A., Cusioli, L. F., Seibert, D., de Oliveira Bezerra, C., & Bergamasco, R. (2019) · Chemosphere · doi:10.1016/j.chemosphere.2019.02.009 · Cited by 557
A review of digital microfluidics as portable platforms for lab-on a-chip applications
Samiei, E., Tabrizian, M., & Hoorfar, M. (2016) · Lab on a Chip · doi:10.1039/c6lc00387g · Cited by 471
Gui, R., Jin, H. Z., Guo, H., & Wang, Z. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.08.058 · Cited by 468
Recent Progress in Biosensors for Environmental Monitoring: A Review
Justino, C., Duarte, A., & Rocha-Santos, T. (2017) · Sensors · doi:10.3390/s17122918 · Cited by 456
Nanomaterials based electrochemical sensor and biosensor platforms for environmental applications
Maduraiveeran, G., & Jin, W. (2017) · Trends in Environmental Analytical Chemistry · doi:10.1016/j.teac.2017.02.001 · Cited by 398
Obasi, P. N., & Akudinobi, B. B. (2020) · Applied Water Science · doi:10.1007/s13201-020-01233-z · Cited by 369
Gui, Q., Lawson, T., Shan, S., Yan, L., & Liu, Y. (2017) · Sensors · doi:10.3390/s17071623 · Cited by 347
Recent advances in DNA-based electrochemical biosensors for heavy metal ion detection: A review
Saidur, M. R., Aziz, A. R. A., & Basirun, W. J. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.11.039 · Cited by 339
Origami multiple paper-based electrochemical biosensors for pesticide detection
Arduini, F., Cinti, S., Caratelli, V., Amendola, L., Palleschi, G., & Moscone, D. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.014 · Cited by 322
Cell-based biosensors: Recent trends, challenges and future perspectives
Gupta, N., Renugopalakrishnan, V., Liepmann, D., Paulmurugan, R., & Malhotra, B. D. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111435 · Cited by 318
Emerging contaminants in the environment: Risk-based analysis for better management
Naidu, R., Arias Espana, V. A., Liu, Y., & Jit, J. (2016) · Chemosphere · doi:10.1016/j.chemosphere.2016.03.068 · Cited by 313
Pesticides Classification and its Impact on Environment
Kaur, R., Mavi, G. K., Raghav, S., & Khan, I. (2019) · International Journal of Current Microbiology and Applied Sciences · doi:10.20546/ijcmas.2019.803.224 · Cited by 302
Biosensors for wastewater monitoring: A review
Ejeian, F., Etedali, P., Mansouri-Tehrani, H.-A., Soozanipour, A., Low, Z.-X., Asadnia, M., Taheri-Kafrani, A., & Razmjou, A. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.07.019 · Cited by 287
Wang, L., Peng, X., Fu, H., Huang, C., Li, Y., & Liu, Z. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111777 · Cited by 279
Jiang, Y., Yang, X., Liang, P., Liu, P., & Huang, X. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.06.099 · Cited by 239
Zhao, H., Ji, X., Wang, B., Wang, N., Li, X., Ni, R., & Ren, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.10.007 · Cited by 233
Microbial fuel cell-based biosensor for online monitoring wastewater quality: A critical review
Do, M. H., Ngo, H. H., Guo, W., Chang, S. W., Nguyen, D. D., Liu, Y., Varjani, S., & Kumar, M. (2019) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2019.135612 · Cited by 229
Microbial Biosensors: Engineered Microorganisms as the Sensing Machinery
Park, M., Tsai, S.-L., & Chen, W. (2013) · Sensors · doi:10.3390/s130505777 · Cited by 220
Bereza-Malcolm, L. T., Mann, G., & Franks, A. E. (2015) · ACS Synthetic Biology · doi:10.1021/sb500286r · Cited by 219
Khanmohammadi, A., Jalili Ghazizadeh, A., Hashemi, P., Afkhami, A., Arduini, F., & Bagheri, H. (2020) · Journal of the Iranian Chemical Society · doi:10.1007/s13738-020-01940-z · Cited by 208
Design and Development of Biosensors for the Detection of Heavy Metal Toxicity
Turdean, G. L. (2011) · International Journal of Electrochemistry · doi:10.4061/2011/343125 · Cited by 197
Applications of a DNA-electrochemical biosensor
Diculescu, V. C., Chiorcea-Paquim, A.-M., & Oliveira-Brett, A. M. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.01.019 · Cited by 197
Microfluidic lab-on-a-chip platforms for environmental monitoring
Pol, R., Céspedes, F., Gabriel, D., & Baeza, M. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.08.001 · Cited by 195
Occurrence of pesticides in Dutch drinking water sources
Sjerps, R. M. A., Kooij, P. J. F., van Loon, A., & Van Wezel, A. P. (2019) · Chemosphere · doi:10.1016/j.chemosphere.2019.06.207 · Cited by 185
Uniyal, S., & Sharma, R. K. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.039 · Cited by 183
A screen-printed paper microbial fuel cell biosensor for detection of toxic compounds in water
Chouler, J., Cruz-Izquierdo, Á., Rengaraj, S., Scott, J. L., & Di Lorenzo, M. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.11.018 · Cited by 178
Uric Acid Monitoring with a Smartphone as the Electrochemical Analyzer
Guo, J. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04345 · Cited by 172
Toxicity assessment using different bioassays and microbial biosensors
Hassan, S. H. A., Van Ginkel, S. W., Hussein, M. A. M., Abskharon, R., & Oh, S.-E. (2016) · Environment International · doi:10.1016/j.envint.2016.03.003 · Cited by 170
Development of biosensor technologies for analysis of environmental contaminants
Wang, X., Lu, X., & Chen, J. (2014) · Trends in Environmental Analytical Chemistry · doi:10.1016/j.teac.2014.04.001 · Cited by 169
Frontiers in electrochemical enzyme based biosensors for food and drug analysis
Kurbanoğlu, S., Erkmen, C., & Uslu, B. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.115809 · Cited by 160
Neonicotinoids: molecular mechanisms of action, insights into resistance and impact on pollinators
Ihara, M., & Matsuda, K. (2018) · Current Opinion in Insect Science · doi:10.1016/j.cois.2018.09.009 · Cited by 159
Toxicity of 10 organic micropollutants and their mixture: Implications for aquatic risk assessment
Shao, Y., Chen, Z., Hollert, H., Zhou, S., Deutschmann, B., & Seiler, T. (2019) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2019.02.047 · Cited by 159
Progress in the sensing techniques for heavy metal ions using nanomaterials
Kumar, P., Kim, K.-H., Bansal, V., Lazarides, T., & Kumar, N. (2017) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2017.06.010 · Cited by 158
Taillebois, E., Cartereau, A., Jones, A. K., & Thany, S. H. (2018) · Pesticide Biochemistry and Physiology · doi:10.1016/j.pestbp.2018.04.007 · Cited by 154
Yu, D., Bai, L., Zhai, J., Wang, Y., & Dong, S. (2017) · Talanta · doi:10.1016/j.talanta.2017.03.048 · Cited by 153
Electrochemical Immunosensors for Antibiotic Detection
Pollap, A., & Kochana, J. (2019) · Biosensors · doi:10.3390/bios9020061 · Cited by 143
Smartphone-Powered Electrochemical Dongle for Point-of-Care Monitoring of Blood β-Ketone
Guo, J. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02531 · Cited by 137
Microfluidics and electrochemistry: an emerging tandem for next-generation analytical microsystems
Fernández‐la‐Villa, A., Pozo‐Ayuso, D. F., & Castaño‐Álvarez, M. (2019) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2019.05.014 · Cited by 137
Toxicity measurement in biological wastewater treatment processes: A review
Xiao, Y., Araujo, C. D., Sze, C. C., & Stuckey, D. C. (2014) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2014.12.033 · Cited by 132
Marsala, R. Z., Capri, E., Russo, E., Bisagni, M., Colla, R., Lucini, L., Gallo, A., & Suciu, N. (2020) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2020.139730 · Cited by 130
Zhu, Y. C., Zeng, G., Zhang, Y., Tang, L., Chen, J. S., Cheng, M., Zhang, L., He, L., Guo, Y., He, X., et al. (2014) · The Analyst · doi:10.1039/c4an00874j · Cited by 130
Cai, W., Xie, S., Zhang, J., Tang, D., & Tang, Y. C. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.025 · Cited by 130
Lang, Q., Han, L., Hou, C., Wang, F., & Liu, A. (2016) · Talanta · doi:10.1016/j.talanta.2016.05.002 · Cited by 127
Reynoso, E. C., Torres, E., Bettazzi, F., & Palchetti, I. (2019) · Biosensors · doi:10.3390/bios9010020 · Cited by 126
Zeng, G., Zhang, C., Huang, D., Lai, C., Tang, L., Zhou, Y., Xu, P., Wang, H., Qin, L., & Cheng, M. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.10.018 · Cited by 125
A neonicotinoid pesticide impairs foraging, but not learning, in free-flying bumblebees
Muth, F., & Leonard, A. S. (2019) · Scientific Reports · doi:10.1038/s41598-019-39701-5 · Cited by 123
Microfluidic electrochemical devices for pollution analysis–A review
Kudr, J., Zítka, O., Klimánek, M., Vrba, R., & Adam, V. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.02.052 · Cited by 120
Bilal, M., & Iqbal, H. M. N. (2019) · Process Safety and Environmental Protection · doi:10.1016/j.psep.2019.01.032 · Cited by 119
Simultaneous monitoring of glucose and uric acid on a single test strip with dual channels
Guo, J., & Ma, X. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.03.026 · Cited by 118
Antibody nanosensors: a detailed review
Wujcik, E. K., Wei, H., Zhang, X., Guo, J., Yan, X., Sutrave, N., Wei, S., & Guo, Z. (2014) · RSC Advances · doi:10.1039/c4ra07119k · Cited by 113
Smirnova, S. V., Ilin, D. V., & Pletnev, I. V. (2021) · Talanta · doi:10.1016/j.talanta.2020.121485 · Cited by 110
Tucci, M., Grattieri, M., Schievano, A., Cristiani, P., & Minteer, S. D. (2019) · Electrochimica Acta · doi:10.1016/j.electacta.2019.02.007 · Cited by 103
Gao, G., Fang, D., Yu, Y., Wu, L., Wang, Y., & Zhi, J. (2017) · Talanta · doi:10.1016/j.talanta.2017.01.081 · Cited by 102
Biosensors for the Detection of Environmental and Urban Pollutions
Goradel, N. H., Mirzaei, H., Sahebkar, A., Poursadeghiyan, M., Masoudifar, A., Malekshahi, Z. V., & Negahdari, B. (2017) · Journal of Cellular Biochemistry · doi:10.1002/jcb.26030 · Cited by 102
Smartphone-Powered Electrochemical Biosensing Dongle for Emerging Medical IoTs Application
Guo, J. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2777145 · Cited by 101
Kumar, T. H. V., & Sundramoorthy, A. K. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.05.011 · Cited by 101
Tsopela, A., Laborde, A., Salvagnac, L., Ventalon, V., Bedel‐Pereira, E., Séguy, I., Temple‐Boyer, P., Juneau, P., Izquierdo, R., & Launay, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.12.050 · Cited by 98
Removal of micropollutants from water in a continuous-flow electrical discharge reactor
Wardenier, N., Vanraes, P., Nikiforov, A. Y., Hulle, S. W. H. V., & Leys, C. (2018) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2018.08.095 · Cited by 95
Advanced sensing technologies of phenolic compounds for pharmaceutical and biomedical analysis
Ge, L., Li, S., & Lisak, G. (2019) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2019.112913 · Cited by 94
On-line monitoring of heavy metals-related toxicity with a microbial fuel cell biosensor
Adekunle, A., Raghavan, V., & Tartakovsky, B. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.03.011 · Cited by 93
Yi, Y., Xie, B., Zhao, T. K., Li, Z., Стом, Д. И., & Liu, H. (2018) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2018.09.003 · Cited by 86
Adekunle, A., Raghavan, V., & Tartakovsky, B. (2018) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2018.11.007 · Cited by 81
da Silva, W., Ghica, M. E., & Brett, C. M. A. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.126862 · Cited by 73
Ghorbani, Y. A., Ghoreishi, S. M., & Ghani, M. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.104786 · Cited by 70
A novel biosensor for zinc detection based on microbial fuel cell system
Khan, A., Salama, E., Chen, Z., Ni, H., Zhao, S., Zhou, T., Pei, Y., Sani, R. K., Ling, Z., Liu, P., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111763 · Cited by 68
Díaz‐González, M., Gutiérrez‐Capitán, M., Niu, P., Baldi, A., Jiménez‐Jorquera, C., & Fernández‐Sánchez, C. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.11.023 · Cited by 65
Kladsomboon, S., Jaiyen, C., Choprathumma, C., Tusai, T., & Apilux, A. (2019) · Environmental Geochemistry and Health · doi:10.1007/s10653-019-00388-2 · Cited by 64
Flampouri, E., Imar, S., OConnell, K., & Singh, B. (2019) · ACS Sensors · doi:10.1021/acssensors.8b01490 · Cited by 63
Self-citationda Silva, W., Ghica, M. E., & Brett, C. M. A. (2019) · Talanta · doi:10.1016/j.talanta.2019.120427 · Cited by 61
Integrated electrochemical biosensor based on algal metabolism for water toxicity analysis
Tsopela, A., Lale, A., Vanhove, E., Reynes, O., Séguy, I., Temple‐Boyer, P., Juneau, P., Izquierdo, R., & Launay, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.05.004 · Cited by 58
A review of centrifugal microfluidics in environmental monitoring
Maguire, I., O’Kennedy, R. J., Ducrée, J., & Regan, F. B. (2018) · Analytical Methods · doi:10.1039/c8ay00361k · Cited by 58
Yao, Y., Wang, G., Chu, G., An, X., Guo, Y., & Sun, X. (2019) · New Journal of Chemistry · doi:10.1039/c9nj02556a · Cited by 57
Xu, W., Zhu, L., Shao, X., Huang, K., & Luo, Y. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.08.033 · Cited by 56
A Paper‐based Mitochondrial Electrochemical Biosensor for Pesticide Detection
Wang, T., Reid, R. C., & Minteer, S. D. (2015) · Electroanalysis · doi:10.1002/elan.201500487 · Cited by 54
A novel electrochemical method to evaluate the cytotoxicity of heavy metals
Zhu, X., Qin, H., Liu, J.-G., Zhang, Z., Lü, Y., Yuan, X., & Wu, D. (2014) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2014.02.030 · Cited by 52
Yang, Y., Fang, D., Liu, Y., Liu, R., Wang, X., Yu, Y., & Zhi, J. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.02.049 · Cited by 51
Electroanalytical Detection of Cr(VI) and Cr(III) Ions Using a Novel Microbial Sensor
Prabhakaran, D., Riotte, J., Sivry, Y., & Subramanian, S. (2017) · Electroanalysis · doi:10.1002/elan.201600458 · Cited by 49
Dalkıran, B. (2020) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2020.107569 · Cited by 46
A Storable Mediatorless Electrochemical Biosensor for Herbicide Detection
Tucci, M., Bombelli, P., Howe, C. J., Vignolini, S., Bocchi, S., & Schievano, A. (2019) · Microorganisms · doi:10.3390/microorganisms7120630 · Cited by 46
Ayenimo, J. G., & Adeloju, S. B. O. (2015) · Talanta · doi:10.1016/j.talanta.2015.01.006 · Cited by 45
Fang, D., Gao, G., Shen, J., Yu, Y., & Zhi, J. (2016) · Electrochimica Acta · doi:10.1016/j.electacta.2016.10.174 · Cited by 45
Pistocchi, A., Dorati, C., Aloe, A., Ginebreda, A., & Marcé, R. (2019) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2018.12.354 · Cited by 43
Stretchable impedance sensor for mammalian cell proliferation measurements
Zhang, X., Wang, W., Li, F., & Voiculescu, I. (2017) · Lab on a Chip · doi:10.1039/c7lc00375g · Cited by 37
Zhang, J., Yang, Z., Liu, Q., & Liang, H. (2019) · Talanta · doi:10.1016/j.talanta.2019.05.031 · Cited by 36
Poly(noradrenalin) based bi-enzyme biosensor for ultrasensitive multi-analyte determination
Liu, L., Chen, C., Chen, C., Kang, X., Zhang, H., Tao, Y., Xie, Q., & Yao, S. (2018) · Talanta · doi:10.1016/j.talanta.2018.10.055 · Cited by 35
Mussel-Inspired Electro-Cross-Linking of Enzymes for the Development of Biosensors
El‐Maiss, J., Cuccarese, M., Maerten, C., Lupattelli, P., Chiummiento, L., Funicello, M., Schaaf, P., Jierry, L., & Boulmedais, F. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b04764 · Cited by 34
Heavy metal ions probe with relative measurement of fiber Bragg grating
Yang, J., Chen, L. H., Zheng, Y., Dong, X., Raghunandhan, R., So, P. L., & Chan, C. C. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.02.038 · Cited by 33
Bae, J., Lim, J. W., & Kim, T. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.03.001 · Cited by 32
Agostino, V., Massaglia, G., Gerosa, M., Sacco, A., Saracco, G., Margaria, V., & Quaglio, M. (2019) · New Biotechnology · doi:10.1016/j.nbt.2019.09.005 · Cited by 32
Kinetics of urease inhibition-based amperometric biosensors for mercury and lead ions detection
Do, J., & Lin, K.-H. (2016) · Journal of the Taiwan Institute of Chemical Engineers · doi:10.1016/j.jtice.2016.03.011 · Cited by 29
Yang, D., Zhao, K., Suarez, F. L., Pacquette, L. H., & Schmitz, D. J. (2017) · Wiley eBooks · doi:10.1002/9781119238102.ch15 · Cited by 29
Pabbi, M., & Mittal, S. K. (2017) · Analytical Methods · doi:10.1039/c7ay00111h · Cited by 28
Kumar, D. N., Alex, S. A., Chandrasekaran, N., & Mukherjee, A. (2016) · RSC Advances · doi:10.1039/c6ra13185a · Cited by 28
Lin, X. H., Aik, S. X. L., Angkasa, J., Le, Q., Chooi, K. S., & Li, S. F. Y. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.11.070 · Cited by 26
Pandey, S. K., Sachan, S., & Singh, S. K. (2019) · Materials Science for Energy Technologies · doi:10.1016/j.mset.2019.08.001 · Cited by 17
Li, G., Li, Z., You, X., Chen, J., & Tang, S. (2016) · Talanta · doi:10.1016/j.talanta.2016.08.042 · Cited by 16
Brennan, L. M., Widder, M. W., McAleer, M. K., Mayo, M. W., Greis, A. P., & van der Schalie, W. H. (2016) · Journal of Visualized Experiments · doi:10.3791/53555 · Cited by 13
Cited by
Current advancements and prospects of enzymatic and non-enzymatic electrochemical glucose sensors
Govindaraj, M., Srivastava, A., Muthukumaran, M. K., Tsai, P.-C., Lin, Y.-C., Raja, B. K., Rajendran, J., Ponnusamy, V. K., & Arockia Selvi, J. (2023) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2023.126680 · Cited by 196
Aryal, P., Hefner, C., Martinez, B., & Henry, C. S. (2024) · Lab on a Chip · doi:10.1039/d3lc00871a · Cited by 176
Advances in electrochemical detection methods for measuring contaminants of emerging concerns
Hassan, M. H., Khan, R., & Andreescu, S. (2022) · Electrochemical Science Advances · doi:10.1002/elsa.202100184 · Cited by 159
Enhancing the sustainability of microalgae cultivation through biosensing technology
Ugya, A. Y., Chen, H., & Wang, Q. (2025) · Materials Today Sustainability · doi:10.1016/j.mtsust.2025.101139 · Cited by 5
Metadata
- Authors
- Hara, T. O., & Singh, B.
- Venue
- ACS ES&T Water
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-02-15
- Volume
- 1
- Issue
- 3
- Pages
- 462-478
- ISSN
- 2690-0637 (ISSN-L)
- OpenAlex
- W3129426331
- Cited by
- 252
- References
- 105
- FWCI
- 11.02
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.