Bioelectrical Impedance Spectroscopy for Monitoring Mammalian Cells and Tissues under Different Frequency Domains: A Review
Open accessThe DOI matches its Crossref record; 117 of the 117 references it cites were found in a registry or an index.
Abstract
Bioelectrical impedance analysis and bioelectrical impedance spectroscopy (BIA/BIS) of tissues reveal important information on molecular composition and physical structure that is useful in diagnostics and prognostics. The heterogeneity in structural elements of cells, tissues, organs, and the whole human body, the variability in molecular composition arising from the dynamics of biochemical reactions, and the contributions of inherently electroresponsive components, such as ions, proteins, and polarized membranes, have rendered bioimpedance challenging to interpret but also a powerful evaluation and monitoring technique in biomedicine. BIA/BIS has thus become the basis for a wide range of diagnostic and monitoring systems such as plethysmography and tomography. The use of BIA/BIS arises from (i) being a noninvasive and safe measurement modality, (ii) its ease of miniaturization, and (iii) multiple technological formats for its biomedical implementation. Considering the dependency of the absolute and relative values of impedance on frequency, and the uniqueness of the origins of the α-, β-, δ-, and γ-dispersions, this targeted review discusses biological events and underlying principles that are employed to analyze the impedance data based on the frequency range. The emergence of BIA/BIS in wearable devices and its relevance to the Internet of Medical Things (IoMT) are introduced and discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Santhosh, S., Juliet, A. V., & Krishnan, G. H. (2020) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-020-02452-7 · Cited by 12
RetractedElectrical Properties of Tissue and Cell Suspensions
Schwan, H. P. (1957) · Advances in Biological and Medical Physics · doi:10.1016/b978-1-4832-3111-2.50008-0 · Cited by 1,620
Bioimpedance and Bioelectricity Basics
(2015) · Elsevier eBooks · doi:10.1016/c2012-0-06951-7 · Cited by 1,175
Electrochemical impedance spectroscopy
Wang, S., Zhang, J., Gharbi, O., Vivier, V., Gao, M., & Orazem, M. E. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00039-w · Cited by 1,140
Schwarz, G. (1962) · The Journal of Physical Chemistry · doi:10.1021/j100818a067 · Cited by 861
Pethig, R., & Kell, D. B. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/8/001 · Cited by 796
Lazebnik, M., McCartney, L., Popovic, D., Watkins, C. B., Lindstrom, M. J., Harter, J. M., Sewall, S., Magliocco, A. M., Booske, J. H., Okoniewski, M., et al. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/10/001 · Cited by 770
The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz
Joines, W. T., Zhang, Y., Li, C., & Jirtle, R. L. (1994) · Medical Physics · doi:10.1118/1.597312 · Cited by 763
Electrical conductivity of tissue at frequencies below 1 MHz
Gabriel, C., Peyman, A., & Grant, E. H. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/16/002 · Cited by 716
Khalil, S., Mohktar, M., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140610895 · Cited by 712
Whole-body impedance–what does it measure?
Foster, K., & Lukaski, H. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.388s · Cited by 429
A review of impedance measurements of whole cells
Xu, Y., Xie, X., Duan, Y., Wang, L., Cheng, Z., & Cheng, J. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.027 · Cited by 424
Kubicek, W. G., Patterson, R. P., & Witsoe, D. A. (1970) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1970.tb17735.x · Cited by 394
Electric Properties of Tissues
Miklavčič, D., Pavšelj, N., & Hart, F. X. (2006) · Wiley Encyclopedia of Biomedical Engineering · doi:10.1002/9780471740360.ebs0403 · Cited by 376
Graphene-Based Sensors for Human Health Monitoring
Huang, H., Su, S., Wu, N., Wan, H., Wan, S., Bi, H., & Sun, L. (2019) · Frontiers in Chemistry · doi:10.3389/fchem.2019.00399 · Cited by 330
Davies, S. J., & Davenport, A. (2014) · Kidney International · doi:10.1038/ki.2014.207 · Cited by 314
Resistant Hypertension: Comparing Hemodynamic Management to Specialist Care
Taler, S. J., Textor, S. C., & Augustine, J. E. (2002) · Hypertension · doi:10.1161/01.hyp.0000016176.16042.2f · Cited by 306
Advances in Biological and Medical Physics
Nias, A. H. W. (1966) · International Journal of Radiation Biology and Related Studies in Physics, Chemistry and Medicine · doi:10.1080/09553006614550861 · Cited by 304
Electrical impedance spectroscopy study of biological tissues
Dean, D. A., Ramanathan, T., Machado, D., & Sundararajan, R. (2008) · Journal of Electrostatics · doi:10.1016/j.elstat.2007.11.005 · Cited by 299
Tomo: Wearable, Low-Cost Electrical Impedance Tomography for Hand Gesture Recognition
Zhang, Y., & Harrison, C. (2015) · Proceedings of the 28th Annual ACM Symposium on User Interface Software & Technology · doi:10.1145/2807442.2807480 · Cited by 283
HAINES, D. E. (1991) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1991.tb01353.x · Cited by 264
Dielectric Properties Characterization From 0.5 to 50 GHz of Breast Cancer Tissues
Martellosio, A., Bellomi, M., Pasian, M., Bozzi, M., Perregrini, L., Mazzanti, A., Svelto, F., Summers, P. E., Renne, G., & Preda, L. (2017) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2016.2631162 · Cited by 261
ELECTRIC IMPEDANCE OF SUSPENSIONS OF SPHERES
Cole, K. S. (1928) · Journal of General Physiology · doi:10.1085/jgp.12.1.29 · Cited by 215
Malvehy, J., Hauschild, A., Curiel‐Lewandrowski, C., Mohr, P., Hofmann‐Wellenhof, R., Motley, R., Berking, C., Grossman, D., Paoli, J., Loquai, C., et al. (2014) · British Journal of Dermatology · doi:10.1111/bjd.13121 · Cited by 210
Moonen, H. P. F. X., & van Zanten, A. R. H. (2021) · Current Opinion in Critical Care · doi:10.1097/mcc.0000000000000840 · Cited by 202
Bioimpedance measurements of human body composition: critical analysis and outlook
Matthie, J. R. (2008) · Expert Review of Medical Devices · doi:10.1586/17434440.5.2.239 · Cited by 199
LOW-FREQUENCY DIELECTRIC PROPERTIES OF BIOLOGICAL TISSUES: A REVIEWWITH SOME NEW INSIGHTS
Kuang, W., & Nelson, S. O. (1998) · Transactions of the ASAE · doi:10.13031/2013.17142 · Cited by 194
Naranjo-Hernández, D., Reina-Tosina, J., & Min, M. (2019) · Journal of Sensors · doi:10.1155/2019/9210258 · Cited by 193
Security in IoMT Communications: A Survey
Koutras, D., Stergiopoulos, G., Dasaklis, T., Kotzanikolaou, P., Glynos, D., & Douligeris, C. (2020) · Sensors · doi:10.3390/s20174828 · Cited by 184
Huynh, T. H., Jafari, R., & Chung, W.-Y. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2865751 · Cited by 178
Barroso, E. M., Smits, R. W. H., Schut, T. C. B., ten Hove, I., Hardillo, J. A., Wolvius, E. B., de Jong, R. J. B., Koljenović, S., & Puppels, G. J. (2015) · Analytical Chemistry · doi:10.1021/ac504362y · Cited by 151
Textile Electrodes for EEG Recording — A Pilot Study
Löfhede, J., Seoane, F., & Thordstein, M. (2012) · Sensors · doi:10.3390/s121216907 · Cited by 145
Vinko Tomicic, F., & Cornejo, R. (2019) · Journal of Thoracic Disease · doi:10.21037/jtd.2019.06.27 · Cited by 145
Hussein, M. I., Awwad, F. R., Jithin, D., Hasasna, H. E., Athamneh, K., & Iratni, R. (2019) · Scientific Reports · doi:10.1038/s41598-019-41124-1 · Cited by 143
Varaki, E. S., Gargiulo, G. D., Penkala, S., & Breen, P. P. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0494-4 · Cited by 142
Romsauerova, A., McEwan, A. L., Lior Horesh, C., Yerworth, R., Bayford, R. H., & Holder, D. S. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/5/s13 · Cited by 141
Accurate, Noninvasive Continuous Monitoring of Cardiac Output by Whole-Body Electrical Bioimpedance
Cotter, G., Moshkovitz, Y., Kaluski, E., Cohen, A. J., Miller, H. I., Goor, D. A., & Vered, Z. (2004) · CHEST Journal · doi:10.1378/chest.125.4.1431 · Cited by 135
Bioimpedance Analysis for the Characterization of Breast Cancer Cells in Suspension
Qiao, G., Wang, W., Duan, W., Zheng, F., Sinclair, A. J., & Chatwin, C. R. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2202904 · Cited by 128
Nakagawa, H., Kautzner, J., Natale, A., Peichl, P., Cihak, R. J., Wichterle, D., Ikeda, A., Santangeli, P., Biase, L. D., & Jackman, W. M. (2013) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.113.978320 · Cited by 121
Dielectric behavior of beef meat in the 1–1500kHz range: Simulation with the Fricke/Cole–Cole model
Damez, J.-L., Clerjon, S., Abouelkaram, S., & Lepetit, J. (2007) · Meat Science · doi:10.1016/j.meatsci.2007.04.028 · Cited by 101
Electrical impedance tomography spectroscopy (EITS) for human head imaging
Yerworth, R., Bayford, R. H., Brown, B. H., Milnes, P., Conway, M., & Holder, D. S. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/358 · Cited by 99
Non-invasive Monitoring of Three Glucose Ranges Based On ECG By Using DBSCAN-CNN
Li, J., Igbe, T., Liu, Y., Kandwal, A., Wang, L., & Nie, Z. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3072628 · Cited by 93
Dielectric spectroscopy of single cells: time domain analysis using Maxwell's mixture equation
Sun, T., Gawad, S., Green, N. G., & Morgan, H. (2006) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/40/1/s01 · Cited by 89
Chien, J., & Niknejad, A. M. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2500362 · Cited by 89
Securing Internet of Medical Things with Friendly-jamming schemes
Li, X., Dai, H., Wang, Q., Imran, M. A., Li, D., & Imran, M. A. (2020) · Computer Communications · doi:10.1016/j.comcom.2020.06.026 · Cited by 84
Toward Impedimetric Measurement of Acidosis with a pH-Responsive Hydrogel Sensor
Bhat, A., Amanor-Boadu, J. M., & Guiseppi‐Elie, A. (2020) · ACS Sensors · doi:10.1021/acssensors.9b02336 · Cited by 83
Self-citationSingle frequency versus bioimpedance spectroscopy for the assessment of lymphedema
York, S., Ward, L. C., Czerniec, S. A., Lee, M. J., Refshauge, K. M., & Kilbreath, S. L. (2008) · Breast Cancer Research and Treatment · doi:10.1007/s10549-008-0090-6 · Cited by 80
Dielectric properties of human blood at microwave frequencies
Alison, J. M., & Sheppard, R. J. (1993) · Physics in Medicine and Biology · doi:10.1088/0031-9155/38/7/007 · Cited by 79
Electrical impedance tomography (EIT) for quantification of pulmonary edema in acute lung injury
Trepte, C. J. C., Phillips, C. R., Solà, J., Adler, A., Haas, S., Rapin, M., Böhm, S. H., & Reuter, D. A. (2016) · Critical Care · doi:10.1186/s13054-015-1173-5 · Cited by 75
Perier, F., Tuffet, S., Maraffi, T., Alcala, G., Júnior, M. H. V., Haudebourg, A.-F., Razazi, K., de Prost, N., Amato, M. B. P., Carteaux, G., et al. (2020) · Critical Care · doi:10.1186/s13054-020-03414-3 · Cited by 74
Multimodal Wrist Biosensor for Wearable Cuff-less Blood Pressure Monitoring System
Rachim, V. P., & Chung, W. (2019) · Scientific Reports · doi:10.1038/s41598-019-44348-3 · Cited by 73
Bera, T. K., Nagaraju, J., & Lubineau, G. (2016) · Journal of Visualization · doi:10.1007/s12650-016-0351-0 · Cited by 73
Gómez-Aguilar, J. F., Bernal, J. J., Rosales, J. J., & Cordova, T. T. (2012) · Journal of Electrical Bioimpedance · doi:10.5617/jeb.225 · Cited by 72
Electrical Impedance Spectroscopy for Monitoring Chemoresistance of Cancer Cells
Crowell, L. L., Yakisich, J. S., Aufderheide, B., & Adams, T. N. G. (2020) · Micromachines · doi:10.3390/mi11090832 · Cited by 72
Electrical Impedance Spectroscopy for Microtissue Spheroid Analysis in Hanging-Drop Networks
Schmid, Y. R. F., Bürgel, S. C., Misun, P. M., Hierlemann, A. R., & Frey, O. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00272 · Cited by 70
Effects of weak electric fields on the activity of neurons and neuronal networks
Jefferys, J. G. R., Deans, J. K., Bikson, M., & Fox, J. (2003) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a006367 · Cited by 70
Tidy, J. A., Brown, B., Healey, T. J., Daayana, S., Martin, M., Prendiville, W. J., & Kitchener, H. C. (2013) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.12096 · Cited by 68
Hirata, A., Takano, Y., Kamimura, Y., & Fujiwara, O. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/9/n03 · Cited by 68
Secure Data Transmission in Internet of Medical Things Using RES-256 Algorithm
Nagarajan, S. M., Devarajan, G. G., Kumaran, U. S., Thirunavukkarasan, M., Alshehri, M. D., & Alkhalaf, S. (2021) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2021.3126119 · Cited by 67
Jung, M. H., Namkoong, K., Lee, Y., Koh, Y. J., Eom, K., Jang, H., Jung, W., Bae, J., & Park, J. (2021) · Scientific Reports · doi:10.1038/s41598-020-79667-3 · Cited by 64
Soucy, J. R., Bindas, A. J., Koppes, A. N., & Koppes, R. A. (2019) · iScience · doi:10.1016/j.isci.2019.10.052 · Cited by 62
A portable bio-impedance system for monitoring lung resistivity
Zlochiver, S., Arad, M., Radai, M. M., Barak‐Shinar, D., Krief, H., Engelman, T., Ben-Yehuda, R., Adunsky, A., & Abboud, S. (2006) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.02.005 · Cited by 62
Li, J., Igbe, T., Liu, Y., Nie, Z., Qin, W., Wang, L., & Hao, Y. (2018) · IEEE Access · doi:10.1109/access.2018.2866601 · Cited by 61
Jahnke, H., Heimann, A., Azendorf, R., Mpoukouvalas, K., Kempski, O. S., Robitzki, A. A., & Charalampaki, P. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.02.013 · Cited by 60
Differentiation of live and heat-killed E. coli by microwave impedance spectroscopy
Li, H., Multari, C. R., Palego, C., Ma, X., Du, X., Ning, Y., Buceta, J., Hwang, J. C. M., & Cheng, X. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.08.179 · Cited by 57
Canali, C., Heiskanen, A. R., Muhammad, H. B., Høyum, P., Pettersen, F., Hemmingsen, M., Wolff, A., Dufva, M., Martinsen, Ø. G., & Emnéus, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.020 · Cited by 55
The Cole relaxation frequency as a parameter to identify cancer in breast tissue
Gregory, W. D., Marx, J. J., Gregory, C. W., Mikkelson, W. M., Tjoe, J. A., & Shell, J. (2012) · Medical Physics · doi:10.1118/1.4725172 · Cited by 51
Bioimpedance analysis of vascular tissue and fluid flow in human and plant body: A review
Prasad, A., & Roy, M. (2020) · Biosystems Engineering · doi:10.1016/j.biosystemseng.2020.06.006 · Cited by 50
Smartphone-Based Bioelectrical Impedance Analysis Devices for Daily Obesity Management
Choi, A., Kim, J. J., Jo, S., Jee, J. H., Heymsfield, S. B., Bhagat, Y. A., Kim, I.-S., & Cho, J. (2015) · Sensors · doi:10.3390/s150922151 · Cited by 49
Alpha-dispersion in human tissue
Grimnes, S., & Martinsen, Ø. G. (2010) · Journal of Physics Conference Series · doi:10.1088/1742-6596/224/1/012073 · Cited by 46
Bioelectrical impedance spectroscopy as a fluid management system in heart failure
Weyer, S., Zink, M. D., Wartzek, T., Leicht, L., Mischke, K., Vollmer, T. R., & Leonhardt, S. K. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/6/917 · Cited by 45
Walsh, K., Galvin, J., Keaney, J., Keelan, E. T., & Széplaki, G. (2018) · Clinical Research in Cardiology · doi:10.1007/s00392-018-1220-8 · Cited by 42
Health Monitoring of Human Multiple Physiological Parameters Based on Wireless Remote Medical System
Zhang, K., & Ling, W. (2020) · IEEE Access · doi:10.1109/access.2020.2987058 · Cited by 40
Zhang, C., Wu, Y., Su, Y., Li, H., Fang, L., & Xing, D. (2021) · Plant Signaling & Behavior · doi:10.1080/15592324.2021.1918867 · Cited by 33
Ultrasound image guidance and robot impedance control for beating-heart surgery
Cheng, L., & Tavakoli, M. (2018) · Control Engineering Practice · doi:10.1016/j.conengprac.2018.08.017 · Cited by 30
Jahnke, H., Poenick, S., Maschke, J., Kendler, M., Simon, J. C., & Robitzki, A. A. (2014) · Cancer Research · doi:10.1158/0008-5472.can-14-0813 · Cited by 29
Fornés-Leal, A., Cardona, N., Frasson, M., Castelló-Palacios, S., Nevárez, A., Pons, V., & Garcia‐Pardo, C. (2019) · IEEE Access · doi:10.1109/access.2019.2903481 · Cited by 29
Abasi, S., Aggas, J. R., Venkatesh, N., Vallavanatt, I. G., & Guiseppi‐Elie, A. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111793 · Cited by 28
Self-citationModified thoracic impedance plethysmography to monitor sleep apnea syndromes
Yasuda, Y., Umezu, A., Horihata, S., Yamamoto, K., Miki, R., & Koike, S. (2005) · Sleep Medicine · doi:10.1016/j.sleep.2004.09.002 · Cited by 28
Abasi, S., Podstawczyk, D. A., Sherback, A. F., & Guiseppi‐Elie, A. (2019) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.9b00705 · Cited by 27
Self-citationBrantlov, S., Jødal, L., Andersen, R. F., Lange, A., Rittig, S., & Ward, L. C. (2019) · The Scientific World JOURNAL · doi:10.1155/2019/4274856 · Cited by 27
A Smart IoT Platform for Personalized Healthcare Monitoring Using Semantic Technologies
Dridi, A., Sassi, S., & Faïz, S. (2017) · IEEE International Conference on Tools with Artificial Intelligence (ICTAI) · doi:10.1109/ictai.2017.00182 · Cited by 27
Kasiviswanathan, U., Poddar, S., Kumar, C., Jit, S., Mahto, S. K., & Sharma, N. (2020) · Journal of Analytical Science & Technology · doi:10.1186/s40543-020-00223-9 · Cited by 27
Cardiac and Hemodynamic Assessment of Patients with Cocaine-Associated Chest Pain Syndromes
Baumann, B. M., Perrone, J., Hornig, S. E., Shofer, F. S., Hollander, J. E., & Hollander, J. E. (2000) · Journal of Toxicology Clinical Toxicology · doi:10.1081/clt-100100933 · Cited by 23
A new six-electrode electrical impedance technique for probing deep organs in the human body
Roy, S. K., Karal, M. A. S., Kadir, M. A., & Rabbani, K. S. E. (2019) · European Biophysics Journal · doi:10.1007/s00249-019-01396-x · Cited by 22
Electrical Impedance Spectroscopy in Plant Biology
Hussain, M. I., El‐Keblawy, A., Akhtar, N., & Elwakil, A. S. (2021) · Sustainable agriculture reviews · doi:10.1007/978-3-030-73245-5_12 · Cited by 22
Canali, C., Mazzoni, C., Larsen, L. B., Heiskanen, A. R., Martinsen, Ø. G., Wolff, A., Dufva, M., & Emnéus, J. (2015) · The Analyst · doi:10.1039/c5an00987a · Cited by 22
Two-component dielectric dispersion impedance biosensor for in-line protein monitoring
Oseev, A., Schmidt, M.-P., Hirsch, S., Brose, A., & Schmidt, B. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.09.118 · Cited by 22
Security Vulnerabilities and Intelligent Solutions for IoMT Systems
Jeyavel, J., Parameswaran, T., Mannan, J. M., & Hariharan, U. (2021) · Internet of Things · doi:10.1007/978-3-030-63937-2_10 · Cited by 21
Meta-analysis of plethysmography and rheography in the diagnosis of deep vein thrombosis
Locker, T. E., Goodacre, S. W., Sampson, F. C., Webster, A. C., & Sutton, A. J. (2006) · Emergency Medicine Journal · doi:10.1136/emj.2005.033381 · Cited by 21
Standalone IoT Bioimpedance Device Supporting Real-Time Online Data Access
Vela, L. M., Kwon, H., Rutkove, S. B., & Sanchez, B. (2019) · IEEE Internet of Things Journal · doi:10.1109/jiot.2019.2929459 · Cited by 21
A CMOS current driver with built-in common-mode signal reduction capability for EIT
Wu, Y., Jiang, D., Langlois, P. J., Bayford, R. H., & Demosthenous, A. (2017) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2017.8094567 · Cited by 20
Nano-Pt ennobling of stainless steel for biomedical applications
Aggas, J. R., Bhat, A., Walther, B. K., & Guiseppi‐Elie, A. (2019) · Electrochimica Acta · doi:10.1016/j.electacta.2019.01.177 · Cited by 20
Self-citationHighly stretchable polymer conductors based on as-prepared PEDOT:PSA/ n -PAA hydrogels
Ma, X., Cai, W., Zhang, S., Guo, J., Peng, X., Qiu, Z., Ying, J., & Wang, J. (2017) · New Journal of Chemistry · doi:10.1039/c7nj03103c · Cited by 19
Optimization of Electrical Stimulation for Safe and Effective Guidance of Human Cells
Zhao, Z., Zhu, K., Li, Y., Zhu, Z., Pan, L., Pan, T., Borgens, R. B., & Zhao, M. (2020) · Bioelectricity · doi:10.1089/bioe.2020.0019 · Cited by 18
Oya, S., Yamashita, H., Iwata, R., Kawasaki, K., Tanabe, A., Yagi, K., Aikou, S., & Seto, Y. (2019) · BMC Surgery · doi:10.1186/s12893-019-0652-z · Cited by 17
Ratiometric Impedance Sensing of Fingers for Robust Identity Authentication
Noh, H. W., Ahn, C.-G., Kong, H., & Sim, J. Y. (2019) · Scientific Reports · doi:10.1038/s41598-019-49792-9 · Cited by 16
Nescolarde, L., Yanguas, J., Lukaski, H., Rodas, G., & Rosell-Ferrer, J. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944437 · Cited by 15
Implementation of a Home Monitoring System for Heart Failure Patients: A Feasibility Study
Kohn, M. S., Haggard, J., Kreindler, J., Birkeland, K. T., Kedan, I., Zimmer, R. J., & Khandwalla, R. M. (2017) · JMIR Research Protocols · doi:10.2196/resprot.5744 · Cited by 15
Toward a hemorrhagic trauma severity score: fusing five physiological biomarkers
Bhat, A., Podstawczyk, D. A., Walther, B. K., Aggas, J. R., Machado-Aranda, D., Ward, K. R., & Guiseppi‐Elie, A. (2020) · Journal of Translational Medicine · doi:10.1186/s12967-020-02516-4 · Cited by 13
Self-citationEmran, S., Hurskainen, M., Tomppo, L., Lappalainen, R., Kullaa, A. M., & Myllymaa, S. (2019) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2019.1692940 · Cited by 13
Preliminary study on parameterization of raw electrical bioimpedance data with 3 frequencies
González-Correa, C.-A., Morales, S. A. J., & Cardenas-Jimenez, J. I. (2022) · Scientific Reports · doi:10.1038/s41598-022-13299-7 · Cited by 13
Lewis, N., Lahuec, C., Renaud, S., McAdams, E. T., Bogónez-Franco, P., Lethias, C., Kellouche, S., Carreiras, F., Pinna, A., Histace, A., et al. (2015) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2015.7348399 · Cited by 13
Bertini, M., Brieda, A., Balla, C., Pollastrelli, A., Smarrazzo, V., Francesco, V., Malagù, M., & Ferrari, R. (2019) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-019-00578-z · Cited by 11
Olmo, A., Yuste, Y., Serrano, J. M., Maldonado-Jacobi, A., Pérez, P., Huertas, G., Pereira, S., Yúfera, A., & de la Portilla, F. (2020) · Sensors · doi:10.3390/s20113152 · Cited by 11
Adcock, A. F., Agbai, C. O., & Yang, L. (2018) · Journal of Analytical Science & Technology · doi:10.1186/s40543-018-0149-x · Cited by 11
Deployment of a wearable biosensor system in the emergency department: a technical feasibility study
Miller, K., Hasdianda, M. A., Jambaulikar, G. D., Baugh, C. W., Divatia, S., Boyer, E. W., & Chai, P. R. (2021) · Hawaii International Conference on System Sciences (HICSS) · doi:10.24251/hicss.2021.433 · Cited by 10
Oh, T. I., Kang, M. J., Jeong, Y. J., Zhang, T., Yeo, S. G., & Park, D. C. (2021) · Diagnostics · doi:10.3390/diagnostics11122354 · Cited by 10
Howe, C. A., Corrigan, R. J., Djalali, M. A., McManaway, C., Grbcich, A., & Aidoo, G. S. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph181910094 · Cited by 9
Chung, Y. J., & Kim, E. Y. (2020) · Surgical Metabolism and Nutrition · doi:10.18858/smn.2020.11.2.53 · Cited by 9
Low Power Contactless Bioimpedance Sensor for Monitoring Breathing Activity
Pavlin, M., Novak, F., & Papa, G. (2021) · Sensors · doi:10.3390/s21062081 · Cited by 9
Towards Continuous Plant Bioimpedance Fitting and Parameter Estimation
Martin, D., Reynolds, J., Daniele, M. A.-A., Lobaton, E. J., & Bozkurt, A. Y. (2021) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors47087.2021.9639492 · Cited by 6
Micro‐electrodes for in situ temperature and bio‐impedance measurement
Leung, T. K. W., Ji, X., Peng, B., Chik, G. K. K., Dai, D. S. H. S., Ge, F., Zhang, T., Cheng, X., Kwok, K., Tsang, A. C. O., et al. (2021) · Nano Select · doi:10.1002/nano.202100041 · Cited by 5
Nguyen, T. A., Echtermeyer, D., Barthel, A., Urban, G. A., & Pliquett, U. F. (2020) · Journal of Electrical Bioimpedance · doi:10.2478/joeb-2020-0008 · Cited by 3
Gani, A. F. A., & Ahmad, M. A. (2021) · Heliyon · doi:10.1016/j.heliyon.2021.e07027 · Cited by 3
Treating solid tumors using tumor treating fields
Bomzon, Z. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-820594-5.00004-6 · Cited by 2
Claudel, J., de Araujo, A. L. A., Nadi, M., & Kourtiche, D. (2019) · Sensors · doi:10.3390/s19153366
Metadata
- Authors
- Abasi, S., Aggas, J. R., Garayar-Leyva, G. G., Walther, B. K., & Guiseppi-Elie, A.
- Venue
- ACS Measurement Science Au
- Publisher
- American Chemical Society (ACS)
- Published
- 2022-08-19
- Volume
- 2
- Issue
- 6
- Pages
- 495-516
- ISSN
- 2694-250X (ISSN-L)
- OpenAlex
- W4294327606
- Cited by
- 179
- References
- 117
- FWCI
- 8.36
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.