Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 188

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Early Detection of SARS-CoV-2 Seroconversion in Humans with Aggregation-Induced Near-Infrared Emission Nanoparticle-Labeled Lateral Flow Immunoassay

Chen, Rui, Ren, Cuiping, Liu, Miao, Ge, Xiaopeng, Qu, Mingsheng, Zhou, Xiaobo, Liang, Mifang, Liu, Yan, Li, Fuyou·2021·ACS Nano

Abstract

An outbreak of coronavirus disease (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) poses great threats to human health and the international economy. To reduce large-scale infection and transmission risk of SARS-CoV-2, a simple, rapid, and sensitive serological diagnostic method is urgently needed. Herein, an aggregation-induced emission (AIE) nanoparticle (AIE 810 NP, λ em = 810 nm)-labeled lateral flow immunoassay was designed for early detection of immunoglobulin M (IgM) and immunoglobulin G (IgG) against SARS-CoV-2 in clinical serum samples. Using a near-infrared (NIR) AIE nanoparticle as the fluorescent reporter (△λ = 145 nm), the autofluorescence from the nitrocellulose membrane and biosample and the excitation background noise were effectively eliminated. After optimization, the limit of detection of IgM and IgG is 0.236 and 0.125 μg mL –1, respectively, commensurate with that of the enzyme-linked immunosorbent assay (ELISA) (0.040 and 0.039 μg mL –1 ). The sensitivity of the proposed AIE 810 NP-based test strip for detecting IgM and IgG is 78 and 95% (172 serum samples), commensurate with that of ELISA (85 and 95%) and better than that of a commercial colloidal gold nanoparticle (AuNP)-based test strip (41 and 85%). Importantly, the time of detecting IgM or IgG with an AIE 810 NP-based test strip in sequential clinical samples is 1–7 days after symptom onset, which is significantly earlier than that with a AuNP-based test strip (8–15 days). Therefore, the NIR-emissive AIE nanoparticle-labeled lateral flow immunoassay holds great potential for early detection of IgM and IgG in a seroconversion window period.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsnano.1c01932

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 188

Metadata

Authors
Chen, R., Ren, C., Liu, M., Ge, X., Qu, M., Zhou, X., Liang, M., Liu, Y., & Li, F.
Venue
ACS Nano
Published
2021-04-30
Volume
15
Issue
5
Pages
8996-9004
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W3157227130
Cited by
188
References
4
FWCI
10.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Early Detection of SARS-CoV-2 Seroconversion in Humans with Aggregation-Induced Near-Infrared Emission Nanoparticle-Labeled Lateral Flow Immunoassay. https://app.cochat.ai/papers/10.1021/acsnano.1c01932
The paper
Chen, R., Ren, C., Liu, M., Ge, X., Qu, M., Zhou, X., Liang, M., Liu, Y., & Li, F. (2021). Early Detection of SARS-CoV-2 Seroconversion in Humans with Aggregation-Induced Near-Infrared Emission Nanoparticle-Labeled Lateral Flow Immunoassay. ACS Nano. https://doi.org/10.1021/acsnano.1c01932

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.