The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Multiplex Serum Cytokine Immunoassay Using Nanoplasmonic Biosensor Microarrays
Open accessAbstract
Precise monitoring of the rapidly changing immune status during the course of a disease requires multiplex analysis of cytokines from frequently sampled human blood. However, the current lack of rapid, multiplex, and low volume assays makes immune monitoring for clinical decision-making (e.g., critically ill patients) impractical. Without such assays, immune monitoring is even virtually impossible for infants and neonates with infectious diseases and/or immune mediated disorders as access to their blood in large quantities is prohibited. Localized surface plasmon resonance (LSPR)-based microfluidic optical biosensing is a promising approach to fill this technical gap as it could potentially permit real-time refractometric detection of biomolecular binding on a metallic nanoparticle surface and sensor miniaturization, both leading to rapid and sample-sparing analyte analysis. Despite this promise, practical implementation of such a microfluidic assay for cytokine biomarker detection in serum samples has not been established primarily due to the limited sensitivity of LSPR biosensing. Here, we developed a high-throughput, label-free, multiarrayed LSPR optical biosensor device with 480 nanoplasmonic sensing spots in microfluidic channel arrays and demonstrated parallel multiplex immunoassays of six cytokines in a complex serum matrix on a single device chip while overcoming technical limitations. The device was fabricated using easy-to-implement, one-step microfluidic patterning and antibody conjugation of gold nanorods (AuNRs). When scanning the scattering light intensity across the microarrays of AuNR ensembles with dark-field imaging optics, our LSPR biosensing technique allowed for high-sensitivity quantitative cytokine measurements at concentrations down to 5-20 pg/mL from a 1 μL serum sample. Using the nanoplasmonic biosensor microarray device, we demonstrated the ability to monitor the inflammatory responses of infants following cardiopulmonary bypass (CPB) surgery through tracking the time-course variations of their serum cytokines. The whole parallel on-chip assays, which involved the loading, incubation, and washing of samples and reagents, and 10-fold replicated multianalyte detection for each sample using the entire biosensor arrays, were completed within 40 min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biosensing with plasmonic nanosensors
Anker, J. N., Hall, W. P., Lyandres, O., Shah, N. C., Zhao, J., & Van Duyne, R. P. (2008) · Nature Materials · doi:10.1038/nmat2162 · Cited by 6,786
Surface Plasmon Resonance Sensors for Detection of Chemical and Biological Species
Homola, J. (2008) · Chemical Reviews · doi:10.1021/cr068107d · Cited by 4,525
Localized Surface Plasmon Resonance Sensors
Mayer, K. M., & Hafner, J. H. (2011) · Chemical Reviews · doi:10.1021/cr100313v · Cited by 4,350
Opal, S. M., & DePalo, V. A. (2000) · Chest · doi:10.1378/chest.117.4.1162 · Cited by 1,752
Plasmonic nanorod metamaterials for biosensing
Kabashin, A. V., Evans, P., Pastkovsky, S., Hendren, W., Wurtz, G. A., Atkinson, R., Pollard, R., Podolskiy, V. A., & Zayats, A. V. (2009) · Nature Materials · doi:10.1038/nmat2546 · Cited by 1,744
Erickson, H. P. (2009) · Biological Procedures Online · doi:10.1007/s12575-009-9008-x · Cited by 1,571
Templated Techniques for the Synthesis and Assembly of Plasmonic Nanostructures
Jones, M. R., Osberg, K. D., Macfarlane, R. J., Langille, M. R., & Mirkin, C. A. (2011) · Chemical Reviews · doi:10.1021/cr1004452 · Cited by 1,159
Plasmonics for future biosensors
Brolo, A. G. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.266 · Cited by 1,074
Haes, A. J., Zou, S., Schatz, G. C., & Duyne, R. P. V. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp036261n · Cited by 1,017
Cytokine patterns in patients with cancer: a systematic review
Lippitz, B. E. (2013) · The Lancet Oncology · doi:10.1016/s1470-2045(12)70582-x · Cited by 905
Cited by
Disposable Sensors in Diagnostics, Food, and Environmental Monitoring
Dincer, C., Bruch, R., Costa‐Rama, E., Fernández‐Abedul, M. T., Merkoçi, A., Manz, A., Urban, G. A., & Güder, F. (2019) · Advanced Materials · doi:10.1002/adma.201806739 · Cited by 955
Cytokines: From Clinical Significance to Quantification
Liu, C., Chu, D., Kalantar‐Zadeh, K., George, J., Young, H. A., & Liu, G. (2021) · Advanced Science · doi:10.1002/advs.202004433 · Cited by 940
Advances and applications of nanophotonic biosensors
Altug, H., Oh, S.-H., Maier, S. A., & Homola, J. (2022) · Nature Nanotechnology · doi:10.1038/s41565-021-01045-5 · Cited by 882
Surface Plasmon Resonance Clinical Biosensors for Medical Diagnostics
Masson, J.-F. (2017) · ACS Sensors · doi:10.1021/acssensors.6b00763 · Cited by 663
Optical Biosensors for the Detection of Pathogenic Microorganisms
Yoo, S. M., & Lee, S. Y. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.09.012 · Cited by 571
Localized Surface Plasmon Resonance Biosensing: Current Challenges and Approaches
Unser, S., Bruzas, I., He, J., & Sagle, L. (2015) · Sensors · doi:10.3390/s150715684 · Cited by 565
Multiplexed Point-of-Care Testing – xPOCT
Dincer, C., Bruch, R., Kling, A., Dittrich, P. S., & Urban, G. A. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2017.03.013 · Cited by 503
Integrating Artificial Intelligence and Nanotechnology for Precision Cancer Medicine
Adir, O., Poley, M., Chen, G., Froim, S., Krinsky, N., Shklover, J., Shainsky‐Roitman, J., Lammers, T., & Schroeder, A. (2020) · Advanced Materials · doi:10.1002/adma.201901989 · Cited by 496
Optical Biosensors Based on Plasmonic Nanostructures: A Review
Spackova, B., Wrobel, P., Bockova, M., & Homola, J. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2624340 · Cited by 421
Microfluidics Based Point‐of‐Care Diagnostics
Pandey, C. M., Augustine, S., Kumar, S., Kumar, S., Nara, S., Srivastava, S., & Malhotra, B. D. (2018) · Biotechnology Journal · doi:10.1002/biot.201700047 · Cited by 273
Label-Free Plasmonic Biosensors for Point-of-Care Diagnostics: A Review
Soler, M., Huertas, C. S., & Lechuga, L. M. (2019) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2019.1554435 · Cited by 236
Conklin, B., Conley, B. M., Hou, Y., Chen, M., & Lee, K.-B. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114636 · Cited by 45
Metadata
- Authors
- Chen, P., Chung, M. T., McHugh, W., Nidetz, R., Li, Y., Fu, J., Cornell, T. T., Shanley, T. P., & Kurabayashi, K.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-03-23
- Volume
- 9
- Issue
- 4
- Pages
- 4173-4181
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2134672431
- Cited by
- 321
- References
- 35
- FWCI
- 11.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.