The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Direct Powering a Real Cardiac Pacemaker by Natural Energy of a Heartbeat
Abstract
Implantable medical devices are widely used for monitoring and treatment of severe diseases. In particular, an implantable cardiac pacemaker is the most effective therapeutic device for treating bradyrhythmia, however its surgical replacement is inevitable every 5-12 years due to the limited life of the built-in battery. Although several approaches of energy harvesting have been explored in this decade for powering cardiac pacemakers, the modern, commercial, and full-function pacemaker has never been powered effectively yet. Here, we report an integrated strategy for directly powering a modern and full-function cardiac pacemaker, which can pace the porcine heart in vivo by harvesting the natural energy of a heartbeat, without using any external energy storage element. The generator includes an elastic skeleton and two piezoelectric composites, which could generate a high-output current of 15 μA in vivo over state-of-the-art performance. This study makes an impressive step toward fabricating a self-powered cardiac pacemaker and resolving the power issue of implantable medical devices by piezoelectric harvesting technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
Self-citationHwang, G., Park, H., Lee, J., Oh, S., Park, K., Byun, M., Park, H., Ahn, G., Jeong, C. K., No, K., et al. (2014) · Advanced Materials · doi:10.1002/adma.201400562 · Cited by 672
In Vivo Powering of Pacemaker by Breathing‐Driven Implanted Triboelectric Nanogenerator
Zheng, Q., Shi, B., Fan, F., Wang, X., Yan, L., Yuan, W., Wang, S., Liu, H., Li, Z., & Wang, Z. L. (2014) · Advanced Materials · doi:10.1002/adma.201402064 · Cited by 603
Dagdeviren, C., Shi, Y., Joe, P., Ghaffari, R., Balooch, G., Usgaonkar, K., Gur, O., Tran, P. L., Crosby, J. R., Meyer, M., et al. (2015) · Nature Materials · doi:10.1038/nmat4289 · Cited by 513
Self-citationMuscle‐Driven In Vivo Nanogenerator
Li, Z., Zhu, G., Yang, R., Wang, A. C., & Wang, Z. L. (2010) · Advanced Materials · doi:10.1002/adma.200904355 · Cited by 441
Powering pacemakers from heartbeat vibrations using linear and nonlinear energy harvesters
Amin Karami, M., & Inman, D. J. (2012) · Applied Physics Letters · doi:10.1063/1.3679102 · Cited by 390
In Vivo Self‐Powered Wireless Transmission Using Biocompatible Flexible Energy Harvesters
Kim, D. H., Shin, H. J., Lee, H., Jeong, C. K., Park, H., Hwang, G., Lee, H., Joe, D. J., Han, J. H., Lee, S. H., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201700341 · Cited by 245
Cited by
A comprehensive review on the state-of-the-art of piezoelectric energy harvesting
Sezer, N., & Koç, M. (2021) · Nano Energy · doi:10.1016/j.nanoen.2020.105567 · Cited by 1,480
Shi, Q., Dong, B., He, T., Sun, Z., Zhu, J., Zhang, Z., & Lee, C. (2020) · InfoMat · doi:10.1002/inf2.12122 · Cited by 661
Development Trends and Perspectives of Future Sensors and MEMS/NEMS
Zhu, J., Liu, X., Shi, Q., He, T., Sun, Z., Guo, X., Liu, W., Sulaiman, O. B., Dong, B., & Lee, C. (2019) · Micromachines · doi:10.3390/mi11010007 · Cited by 443
Piezoelectric nanogenerators for personalized healthcare
Deng, W., Zhou, Y., Libanori, A., Chen, G., Yang, W., & Chen, J. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00858g · Cited by 434
Liu, L., Guo, X., & Lee, C. (2021) · Nano Energy · doi:10.1016/j.nanoen.2021.106304 · Cited by 402
Metadata
- Authors
- Li, N., Yi, Z., Ma, Y., Xie, F., Huang, Y., Tian, Y., Dong, X., Liu, Y., Shao, X., Li, Y., Jin, L., Liu, J., Xu, Z., Yang, B., & Zhang, H.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-02-20
- Volume
- 13
- Issue
- 3
- Pages
- 2822-2830
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2913737555
- Cited by
- 198
- References
- 7
- FWCI
- 15.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.