The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Waveguide-Integrated Black Phosphorus Photodetector for Mid-Infrared Applications
Abstract
Midinfrared (MIR), which covers numerous molecular vibrational fingerprints, has attracted enormous research interest due to its promising potential for label-free and damage-free sensing. Despite intense development efforts, the realization of waveguide-integrated on-chip sensing system has seen very limited success to date. The huge lattice mismatch between silicon and the commonly used detection materials such as HgCdTe, III–V, or II–VI compounds has been the key bottleneck that hinders their integration. Here, we realize an integration of silicon-on-insulator (SOI) waveguides with black phosphorus (BP) photodetectors. When operating near BP’s cutoff wavelength where absorption is weak, the light–BP interaction is enhanced by exploiting the optical confinement in the Si waveguide and grating structure to overcome the limitation of absorption length constrained by the BP thickness. Devices with different BP crystal orientation and thickness are compared in terms of their responsivity and noise equivalent power (NEP). Spectral photoresponse from 3.68 to 4.03 μm was investigated. Additionally, power-dependent responsivity and gate-tunable photocurrent were also studied. At a bias of 1 V, the BP photodetector achieved a responsivity of 23 A/W at 3.68 μm and 2 A/W at 4 μm and a NEP less than 1 nW/Hz 1/2 at room temperature. The integration of passive Si photonics and active BP photodetector is envisaged to offer a potential pathway toward the realization of integrated on-chip systems for MIR sensing applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mid-infrared plasmonic biosensing with graphene
Rodrigo, D., Limaj, O., Janner, D., Etezadi, D., García de Abajo, F. J., Pruneri, V., & Altug, H. (2015) · Science · doi:10.1126/science.aab2051 · Cited by 1,462
High-responsivity graphene/silicon-heterostructure waveguide photodetectors
Wang, X., Cheng, Z., Xu, K., Tsang, H. K., & Xu, J.-B. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.241 · Cited by 873
Mid-infrared HgTe colloidal quantum dot photodetectors
Keuleyan, S., Lhuillier, E., Brajuskovic, V., & Guyot-Sionnest, P. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.142 · Cited by 503
Wang, R., Sprengel, S., Muneeb, M., Boehm, G., Baets, R., Amann, M.-C., & Roelkens, G. (2015) · Optics Express · doi:10.1364/oe.23.026834 · Cited by 49
Cited by
Silicon/2D-material photodetectors: from near-infrared to mid-infrared
Liu, C., Guo, J., Yu, L., Li, J., Zhang, M., Li, H., Shi, Y., & Dai, D. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00551-4 · Cited by 473
2D Material Optoelectronics for Information Functional Device Applications: Status and Challenges
Tan, T., Jiang, X., Wang, C., Yao, B., & Zhang, H. (2020) · Advanced Science · doi:10.1002/advs.202000058 · Cited by 458
Zeng, L., Wu, D., Jie, J., Ren, X., Hu, X., Lau, S. P., Chai, Y., & Tsang, Y. H. (2020) · Advanced Materials · doi:10.1002/adma.202004412 · Cited by 419
Xu, Y., Shi, Z., Shi, X., Zhang, K., & Zhang, H. (2019) · Nanoscale · doi:10.1039/c9nr04348a · Cited by 340
Infrared Photodetectors Based on 2D Materials and Nanophotonics
Zha, J., Luo, M., Ye, M., Ahmed, T., Yu, X., Lien, D., He, Q., Lei, D., Ho, J. C., Bullock, J., et al. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202111970 · Cited by 331
Black phosphorus and its isoelectronic materials
Xia, F., Wang, H., Hwang, J. C. M., Neto, A. H. C., & Yang, L. (2019) · Nature Reviews Physics · doi:10.1038/s42254-019-0043-5 · Cited by 322
Self-citationDesign strategies for two‐dimensional material photodetectors to enhance device performance
Wang, J., Han, J., Chen, X., & Wang, X. (2019) · InfoMat · doi:10.1002/inf2.12004 · Cited by 268
High-performance silicon−graphene hybrid plasmonic waveguide photodetectors beyond 1.55 μm
Guo, J., Li, J., Liu, C., Yin, Y., Wang, W., Ni, Z., Fu, Z., Yu, H., Xu, Y., Shi, Y., et al. (2020) · Light: Science & Applications · doi:10.1038/s41377-020-0263-6 · Cited by 260
Wei, J., Li, Y., Wang, L., Liao, W., Dong, B., Xu, C., Zhu, C., Ang, K.-W., Qiu, C.-W., & Lee, C. (2020) · Nature Communications · doi:10.1038/s41467-020-20115-1 · Cited by 233
Self-citationHigh‐Speed and High‐Responsivity Hybrid Silicon/Black‐Phosphorus Waveguide Photodetectors at 2 µm
Yin, Y., Cao, R., Guo, J., Liu, C., Li, J., Feng, X., Wang, H., Du, W., Qadir, A., Zhang, H., et al. (2019) · Laser & Photonics Reviews · doi:10.1002/lpor.201900032 · Cited by 130
Self-citationGherabli, R., Indukuri, S. R. K. C., Zektzer, R., Frydendahl, C., & Levy, U. (2023) · Light: Science & Applications · doi:10.1038/s41377-023-01088-4 · Cited by 82
Mid-Infrared Nanometallic Antenna Assisted Silicon Waveguide Based Bolometers
Wu, Y., Qu, Z., Osman, A., Cao, W., Khokhar, A. Z., Soler Penades, J., Muskens, O. L., Mashanovich, G. Z., & Nedeljkovic, M. (2019) · ACS Photonics · doi:10.1021/acsphotonics.9b01198 · Cited by 46
Shim, J., Lim, J., Kim, I., Jeong, J., Kim, B. H., Kim, S. K., Geum, D.-M., & Kim, S. (2025) · Light: Science & Applications · doi:10.1038/s41377-025-01803-3 · Cited by 31
“More recently, two-dimensional materials (e.g., graphene 16 and black phosphorus 17 ) have arisen as promising candidates that can be operated at room temperature 18 .”
Nanometallic antenna-assisted amorphous silicon waveguide integrated bolometer for mid-infrared
Wu, Y., Qu, Z., Osman, A., Wei, C., Cao, W., Tarazona, A., Oo, S. Z., Chong, H. M. H., Muskens, O. L., Mashanovich, G. Z., et al. (2021) · Optics Letters · doi:10.1364/ol.412529 · Cited by 29
Metadata
- Authors
- Huang, L., Dong, B., Guo, X., Chang, Y., Chen, N., Huang, X., Liao, W., Zhu, C., Wang, H., Lee, C., & Ang, K.-W.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-12-26
- Volume
- 13
- Issue
- 1
- Pages
- 913-921
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2906579457
- Cited by
- 246
- References
- 4
- FWCI
- 8.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.