Reusable Functionalized Hydrogel Sorbents for Removing Long- and Short-Chain Perfluoroalkyl Acids (PFAAs) and GenX from Aqueous Solution
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Abstract Per- and poly-fluoroalkyl substances (PFASs) are man-made chemicals that are toxic and widely detected in the environment, including drinking water sources. A cost-effective treatment process for PFASs is currently not available. We developed reusable hydrogel sorbents to remove long- and short-chain perfluoroalkyl acids and 2,3,3,3-tetrafluoro-2-(heptafluoropropoxy)propanoic acid (GenX), which is are emerging PFAS. Through fluoridation and amination of poly(ethylene glycol) diacrylate (PEGDA), the newly synthesized sorbents can sorb the five targeted PFASs (perfluorooctanoic acid (PFOA), perfluorooctanesulfonic acid (PFOS), perfluorobutanesulfonic acid (PFBS), and perfluorobutanoic acid (PFBA) and GenX) to different degrees from aqueous solution. Aminated PEGDA showed the highest sorption capacity for all five PFASs, particularly for PFBA and PFBS. The bifunctionalized PEGDA showed higher capacities for PFOA and PFOS, suggesting that both hydrophobic interactions and charges contribute to the sorption. Both aminated and bifunctionalized sorbents can remove GenX from water, with the highest sorption capacity of 98.7 μmol g aminated PEGDA–1 within 6 h. The absorbed PFASs on the sorbents were observed and characterized by Fourier-transform infrared spectroscopy. The spent sorbents were reusable after readily regenerated with 70% methanol contained 1% NaCl.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Never-Ending Story of Per- and Polyfluoroalkyl Substances (PFASs)?
Wang, Z., DeWitt, J. C., Higgins, C. P., & Cousins, I. T. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.6b04806 · Cited by 1,921
Hu, X. C., Andrews, D. Q., Lindstrom, A. B., Bruton, T. A., Schaider, L. A., Grandjean, P., Lohmann, R., Carignan, C. C., Blum, A., Balan, S. A., et al. (2016) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.6b00260 · Cited by 1,333
Rahman, M. F., Peldszus, S., & Anderson, W. B. (2014) · Water Research · doi:10.1016/j.watres.2013.10.045 · Cited by 1,022
Sun, M., Arevalo, E., Strynar, M., Lindstrom, A., Richardson, M., Kearns, B., Pickett, A., Smith, C., & Knappe, D. R. U. (2016) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.6b00398 · Cited by 688
Gebbink, W. A., van Asseldonk, L., & van Leeuwen, S. P. J. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.7b02488 · Cited by 438
Comparing the toxic potency in vivo of long-chain perfluoroalkyl acids and fluorinated alternatives
Gomis, M. I., Vestergren, R., Borg, D., & Cousins, I. T. (2018) · Environment International · doi:10.1016/j.envint.2018.01.011 · Cited by 438
Zaggia, A., Conte, L., Falletti, L., Fant, M., & Chiorboli, A. (2016) · Water Research · doi:10.1016/j.watres.2015.12.039 · Cited by 410
The Adsorption of Perfluorooctane Sulfonate onto Sand, Clay, and Iron Oxide Surfaces
Johnson, R. L., Anschutz, A. J., Smolen, J. M., Simcik, M. F., & Penn, R. L. (2007) · Journal of Chemical & Engineering Data · doi:10.1021/je060285g · Cited by 389
Zhou, Z., Liang, Y., Shi, Y., Xu, L., & Cai, Y. (2013) · Environmental Science & Technology · doi:10.1021/es402120y · Cited by 324
Recently Detected Drinking Water Contaminants: GenX and Other Per‐ and Polyfluoroalkyl Ether Acids
Hopkins, Z. R., Sun, M., DeWitt, J. C., & Knappe, D. R. U. (2018) · Journal AWWA · doi:10.1002/awwa.1073 · Cited by 288
Washington, J. W., Yoo, H., Ellington, J. J., Jenkins, T. M., & Libelo, E. L. (2010) · Environmental Science & Technology · doi:10.1021/es1003846 · Cited by 252
Guelfo, J. L., & Adamson, D. T. (2018) · Environmental Pollution · doi:10.1016/j.envpol.2018.01.066 · Cited by 216
Sorption of perfluorinated compounds from contaminated water to activated carbon
Hansen, M. C., Børresen, M. H., Schlabach, M., & Cornelissen, G. (2010) · Journal of Soils and Sediments · doi:10.1007/s11368-009-0172-z · Cited by 175
Cited by
Zhang, C., Yan, K., Fu, C., Peng, H., Hawker, C. J., & Whittaker, A. K. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00632 · Cited by 493
Phong Vo, H. N., Ngo, H. H., Guo, W., Hong Nguyen, T. M., Li, J., Liang, H., Deng, L., Chen, Z., & Hang Nguyen, T. A. (2020) · Journal of Water Process Engineering · doi:10.1016/j.jwpe.2020.101393 · Cited by 291
Self-citationSorption of perfluoroalkylated substances (PFASs) onto granular activated carbon and biochar
Zhang, D., He, Q., Wang, M., Zhang, W., & Liang, Y. (2021) · Environmental Technology · doi:10.1080/09593330.2019.1680744 · Cited by 164
Ionic Fluorogels for Remediation of Per- and Polyfluorinated Alkyl Substances from Water
Kumarasamy, E., Manning, I. M., Collins, L. B., Coronell, O., & Leibfarth, F. A. (2020) · ACS Central Science · doi:10.1021/acscentsci.9b01224 · Cited by 162
Heidari, H., Abbas, T., Ok, Y. S., Tsang, D. C. W., Bhatnagar, A., & Khan, E. (2021) · Water Research · doi:10.1016/j.watres.2021.117683 · Cited by 78
Metadata
- Authors
- Huang, P.-J., Hwangbo, M., Chen, Z., Liu, Y., Kameoka, J., & Chu, K.-H.
- Venue
- ACS Omega
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-12-17
- Volume
- 3
- Issue
- 12
- Pages
- 17447-17455
- ISSN
- 2470-1343 (ISSN-L)
- OpenAlex
- W2905518875
- Cited by
- 125
- References
- 13
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.