Colorimetric Test for Fast Detection of SARS-CoV-2 in Nasal and Throat Swabs
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Abstract Mass testing is fundamental to face the pandemic caused by the coronavirus SARS-CoV-2 discovered at the end of 2019. To this aim, it is necessary to establish reliable, fast and cheap tools to detect viral particles in biological material so to identify the people capable to spread the infection. We demonstrate that a colorimetric biosensor based on gold nanoparticle (AuNP) interaction induced by SARS-CoV-2 lends itself as an outstanding tool for detecting viral particles in nasal and throat swabs. The extinction spectrum of a colloidal solution of multiple viral-target gold nanoparticles – AuNPs functionalized with antibodies targeting three surface proteins of SARS-CoV-2 (spike, envelope and membrane) – is redshifted in few minutes when mixed to a solution containing the viral particle. The optical density of the mixed solution measured at 560 nm was compared to the threshold cycle ( C t ) of a Real Time-PCR (gold standard for detecting the presence of viruses) finding that the colorimetric method is able to detect very low viral load with a detection limit approaching that of RT-PCR. Since the method is sensitive to the infecting viral particle rather than to its RNA, the achievements reported here open new perspective not only in the context of the current and possible future pandemics, but also in microbiology as the biosensor proves itself to be a powerful though simple tool for measuring the viral particle concentration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A novel coronavirus from patients with pneumonia in China, 2019
Zhu, N., Zhang, D., Wang, W., Li, X., Yang, B., Song, J., Zhao, X., Huang, B., Shi, W., Lu, R., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2001017 · Cited by 28,244
CRC Handbook of Chemistry and Physics
(2016) · CRC Press eBooks · doi:10.1201/9781315380476 · Cited by 13,921
Surface plasmon resonance in gold nanoparticles: a review
Amendola, V., Pilot, R., Frasconi, M., Maragò, O. M., & Iatì, M. A. (2017) · Journal of Physics: Condensed Matter · doi:10.1088/1361-648x/aa60f3 · Cited by 1,905
Li, Z., Yi, Y., Luo, X., Xiong, N., Liu, Y., Li, S., Sun, R., Wang, Y., Hu, B., Chen, W., et al. (2020) · Journal of Medical Virology · doi:10.1002/jmv.25727 · Cited by 1,771
Plasmon-enhanced optical sensors: a review
Li, M., Cushing, S. K., & Wu, N. (2015) · The Analyst · doi:10.1039/c4an01079e · Cited by 1,011
SARS-CoV-2 (COVID-19) by the numbers
Bar-On, Y. M., Flamholz, A., Phillips, R., & Milo, R. (2020) · eLife · doi:10.7554/elife.57309 · Cited by 962
The Hill equation: a review of its capabilities in pharmacological modelling
Goutelle, S., Maurin, M., Rougier, F., Barbaut, X., Bourguignon, L., Ducher, M., & Maire, P. (2008) · Fundamental & Clinical Pharmacology · doi:10.1111/j.1472-8206.2008.00633.x · Cited by 867
Real-time reverse transcription PCR (qRT-PCR) and its potential use in clinical diagnosis
Bustin, S. A., & Mueller, R. (2005) · Clinical Science · doi:10.1042/cs20050086 · Cited by 529
Various methods of gold nanoparticles (GNPs) conjugation to antibodies
Jazayeri, M. H., Amani, H., Pourfatollah, A. A., Pazoki-Toroudi, H., & Sedighimoghaddam, B. (2016) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2016.04.002 · Cited by 528
Esbin, M. N., Whitney, O. N., Chong, S., Maurer, A., Darzacq, X., & Tjian, R. (2020) · RNA · doi:10.1261/rna.076232.120 · Cited by 477
Review of surface plasmon resonance and localized surface plasmon resonance sensor
Chen, Y., & Ming, H. (2012) · Photonic Sensors · doi:10.1007/s13320-011-0051-2 · Cited by 401
Evaluation of nine commercial SARS-CoV-2 immunoassays
Lassaunière, R., Frische, A., Harboe, Z. B., Nielsen, A. C. Y., Fomsgaard, A., Krogfelt, K. A., & Jørgensen, C. S. (2020) · medRxiv · doi:10.1101/2020.04.09.20056325 · Cited by 317
Baker, A. N., Richards, S.-J., Guy, C. S., Congdon, T. R., Hasan, M., Zwetsloot, A. J., Gallo, A., Lewandowski, J. R., Stansfeld, P. J., Straube, A., et al. (2020) · ACS Central Science · doi:10.1021/acscentsci.0c00855 · Cited by 303
Plasmon-Based Colorimetric Nanosensors for Ultrasensitive Molecular Diagnostics
Tang, L., & Li, J. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00282 · Cited by 299
Montesinos, I., Gruson, D., Kabamba, B., Dahma, H., Van den Wijngaert, S., Reza, S., Carbone, V., Vandenberg, O., Gulbis, B., Wolff, F., et al. (2020) · Journal of Clinical Virology · doi:10.1016/j.jcv.2020.104413 · Cited by 271
Rapid Scaling Up of Covid-19 Diagnostic Testing in the United States — The NIH RADx Initiative
Tromberg, B. J., Schwetz, T. A., Pérez-Stable, E. J., Hodes, R. J., Woychik, R. P., Bright, R. A., Fleurence, R. L., & Collins, F. S. (2020) · New England Journal of Medicine · doi:10.1056/nejmsr2022263 · Cited by 256
Detecting the Coronavirus (COVID-19)
Pokhrel, P., Hu, C., & Mao, H. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01153 · Cited by 237
Cooperativity Principles in Self-Assembled Nanomedicine
Li, Y., Wang, Y., Huang, G., & Gao, J. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00195 · Cited by 191
Colorimetric detection of influenza A virus using antibody-functionalized gold nanoparticles
Liu, Y., Zhang, L., Wei, W., Zhao, H., Zhou, Z.-X., Zhang, Y., & Liu, S. (2015) · The Analyst · doi:10.1039/c5an00407a · Cited by 154
Tian, W. L., Huang, C., Shi, F., Zeng, X.-Y., Tian, L., Ding, S., & Jiao, Y.-J. (2020) · The Analyst · doi:10.1039/d0an00629g · Cited by 149
QCM-based immunosensor for rapid detection of Salmonella Typhimurium in food
Fulgione, A., Cimafonte, M., Ventura, B. D., Iannaccone, M., Ambrosino, C., Capuano, F., Proroga, Y. T. R., Velotta, R., & Capparelli, R. (2018) · Scientific Reports · doi:10.1038/s41598-018-34285-y · Cited by 104
Self-citationColorimetric Immunosensor by Aggregation of Photochemically Functionalized Gold Nanoparticles
Iarossi, M., Schiattarella, C., Rea, I., Stefano, L. D., Fittipaldi, R., Vecchione, A., Velotta, R., & Ventura, B. D. (2018) · ACS Omega · doi:10.1021/acsomega.8b00265 · Cited by 96
Self-citationPCR for detection of respiratory viruses: seasonal variations of virus infections
Olofsson, S., Brittain-Long, R., Andersson, L. M., Westin, J., & Lindh, M. (2011) · Expert Review of Anti-infective Therapy · doi:10.1586/eri.11.75 · Cited by 87
The explosion of new coronavirus tests that could help to end the pandemic
Guglielmi, G. (2020) · Nature · doi:10.1038/d41586-020-02140-8 · Cited by 86
Ma, L., Zhu, S., Tian, Y., Zhang, W., Wang, S., Chen, C., Wu, L., & Yan, X. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201603007 · Cited by 76
Viral respiratory infections diagnosed by multiplex polymerase chain reaction in pediatric patients
Appak, Ö., Duman, M., Belet, N., & Sayıner, A. A. (2018) · Journal of Medical Virology · doi:10.1002/jmv.25379 · Cited by 66
Ventura, B. D., Banchelli, M., Funari, R., Illiano, A., de Angelis, M., Taroni, P., Amoresano, A., Matteini, P., & Velotta, R. (2019) · The Analyst · doi:10.1039/c9an00443b · Cited by 62
Self-citationMotley, M. P., Bennett‐Guerrero, E., Fries, B. C., & Spitzer, E. D. (2020) · Critical Care Explorations · doi:10.1097/cce.0000000000000154 · Cited by 36
Chaudhary, A., Khan, S., Gupta, A., & Nandi, C. K. (2016) · New Journal of Chemistry · doi:10.1039/c5nj03720d · Cited by 31
Cited by
Miranda, B., Rea, I., Dardano, P., De Stefano, L., & Forestiere, C. (2021) · Biosensors · doi:10.3390/bios11040107 · Cited by 63
Metadata
- Authors
- Ventura, B. D., Cennamo, M., Minopoli, A., Campanile, R., Censi, S. B., Terracciano, D., Portella, G., & Velotta, R.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-09-29
- Volume
- 5
- Issue
- 10
- Pages
- 3043-3048
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W3088627492
- Cited by
- 203
- References
- 29
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.