The DOI matches its Crossref record; 123 of the 123 references it cites were found in a registry or an index.
Antifouling Strategies for Electrochemical Biosensing: Mechanisms and Performance toward Point of Care Based Diagnostic Applications
Open accessAbstract
Although there exist numerous established laboratory-based technologies for sample diagnostics and analyte detection, many medical and forensic science applications require point of care based platforms for rapid on-the-spot sample analysis. Electrochemical biosensors provide a promising avenue for such applications due to the portability and functional simplicity of the technology. However, the ability to develop such platforms with the high sensitivity and selectivity required for analysis of low analyte concentrations in complex biological samples remains a paramount issue in the field of biosensing. Nonspecific adsorption, or fouling, at the electrode interface via the innumerable biomolecules present in these sample types (i.e., serum, urine, blood/plasma, and saliva) can drastically obstruct electrochemical performance, increasing background "noise" and diminishing both the electrochemical signal magnitude and specificity of the biosensor. Consequently, this review aims to discuss strategies and concepts used throughout the literature to prevent electrode surface fouling in biosensors and to communicate the nature of the antifouling mechanisms by which they operate. Evaluation of each antifouling strategy is focused primarily on the fabrication method, experimental technique, sample composition, and electrochemical performance of each technology highlighting the overall feasibility of the platform for point of care based diagnostic/detection applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atomic structure and chemistry of human serum albumin
He, X. M., & Carter, D. C. (1992) · Nature · doi:10.1038/358209a0 · Cited by 3,824
Graphene Based Electrochemical Sensors and Biosensors: A Review
Shao, Y., Wang, J., Wu, H., Liu, J., Aksay, I. A., & Lin, Y. (2010) · Electroanalysis · doi:10.1002/elan.200900571 · Cited by 3,124
Self-Assembled Organic Monolayers: Model Systems for Studying Adsorption of Proteins at Aurfaces
Prime, K. L., & Whitesides, G. M. (1991) · Science · doi:10.1126/science.252.5009.1164 · Cited by 1,831
A Survey of Structure−Property Relationships of Surfaces that Resist the Adsorption of Protein
Ostuni, E., Chapman, R. G., Holmlin, R. E., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la010384m · Cited by 1,799
Electrochemical Sensing and Biosensing Platform Based on Chemically Reduced Graphene Oxide
Zhou, M., Zhai, Y., & Dong, S. (2009) · Analytical Chemistry · doi:10.1021/ac900136z · Cited by 1,706
Protein—surface interactions in the presence of polyethylene oxide
Jeon, S. I., Lee, J. H., Andrade, J. D., & De Gennes, P. G. (1991) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(91)90043-8 · Cited by 1,523
Glucose Oxidase–graphene–chitosan modified electrode for direct electrochemistry and glucose sensing
Kang, X., Wang, J., Wu, H., Aksay, I. A., Liu, J., & Lin, Y. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.09.004 · Cited by 1,229
Pinson, J., & Podvorica, F. (2005) · Chemical Society Reviews · doi:10.1039/b406228k · Cited by 1,193
Application of graphene-modified electrode for selective detection of dopamine
Wang, Y., Li, Y., Tang, L., Lu, J., & Li, J. (2009) · Electrochemistry Communications · doi:10.1016/j.elecom.2009.02.013 · Cited by 1,117
Chen, S., Zheng, J., Li, L., & Jiang, S. (2005) · Journal of the American Chemical Society · doi:10.1021/ja054169u · Cited by 1,038
Cited by
Dong, T., Matos Pires, N. M., Yang, Z., & Jiang, Z. (2023) · Advanced Science · doi:10.1002/advs.202205429 · Cited by 104
Metadata
- Authors
- Russo, M. J., Han, M., Desroches, P. E., Manasa, C. S., Dennaoui, J., Quigley, A. F., Kapsa, R. M. I., Moulton, S. E., Guijt, R. M., Greene, G. W., & Silva, S. M.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-03-25
- Volume
- 6
- Issue
- 4
- Pages
- 1482-1507
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W3138428755
- Cited by
- 338
- References
- 123
- FWCI
- 11.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Antifouling Strategies for Electrochemical Biosensing: Mechanisms and Performance toward Point of Care Based Diagnostic Applications. https://app.cochat.ai/papers/10.1021/acssensors.1c00390
- The paper
- Russo, M. J., Han, M., Desroches, P. E., Manasa, C. S., Dennaoui, J., Quigley, A. F., Kapsa, R. M. I., Moulton, S. E., Guijt, R. M., Greene, G. W., & Silva, S. M. (2021). Antifouling Strategies for Electrochemical Biosensing: Mechanisms and Performance toward Point of Care Based Diagnostic Applications. ACS Sensors. https://doi.org/10.1021/acssensors.1c00390
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.