The DOI matches its Crossref record; 123 of the 123 references it cites were found in a registry or an index.
Antifouling Strategies for Electrochemical Biosensing: Mechanisms and Performance toward Point of Care Based Diagnostic Applications
Open accessAbstract
Although there exist numerous established laboratory-based technologies for sample diagnostics and analyte detection, many medical and forensic science applications require point of care based platforms for rapid on-the-spot sample analysis. Electrochemical biosensors provide a promising avenue for such applications due to the portability and functional simplicity of the technology. However, the ability to develop such platforms with the high sensitivity and selectivity required for analysis of low analyte concentrations in complex biological samples remains a paramount issue in the field of biosensing. Nonspecific adsorption, or fouling, at the electrode interface via the innumerable biomolecules present in these sample types (i.e., serum, urine, blood/plasma, and saliva) can drastically obstruct electrochemical performance, increasing background "noise" and diminishing both the electrochemical signal magnitude and specificity of the biosensor. Consequently, this review aims to discuss strategies and concepts used throughout the literature to prevent electrode surface fouling in biosensors and to communicate the nature of the antifouling mechanisms by which they operate. Evaluation of each antifouling strategy is focused primarily on the fabrication method, experimental technique, sample composition, and electrochemical performance of each technology highlighting the overall feasibility of the platform for point of care based diagnostic/detection applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atomic structure and chemistry of human serum albumin
He, X. M., & Carter, D. C. (1992) · Nature · doi:10.1038/358209a0 · Cited by 3,824
Graphene Based Electrochemical Sensors and Biosensors: A Review
Shao, Y., Wang, J., Wu, H., Liu, J., Aksay, I. A., & Lin, Y. (2010) · Electroanalysis · doi:10.1002/elan.200900571 · Cited by 3,124
Self-Assembled Organic Monolayers: Model Systems for Studying Adsorption of Proteins at Aurfaces
Prime, K. L., & Whitesides, G. M. (1991) · Science · doi:10.1126/science.252.5009.1164 · Cited by 1,831
A Survey of Structure−Property Relationships of Surfaces that Resist the Adsorption of Protein
Ostuni, E., Chapman, R. G., Holmlin, R. E., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la010384m · Cited by 1,799
Electrochemical Sensing and Biosensing Platform Based on Chemically Reduced Graphene Oxide
Zhou, M., Zhai, Y., & Dong, S. (2009) · Analytical Chemistry · doi:10.1021/ac900136z · Cited by 1,706
Protein—surface interactions in the presence of polyethylene oxide
Jeon, S. I., Lee, J. H., Andrade, J. D., & De Gennes, P. G. (1991) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(91)90043-8 · Cited by 1,523
Glucose Oxidase–graphene–chitosan modified electrode for direct electrochemistry and glucose sensing
Kang, X., Wang, J., Wu, H., Aksay, I. A., Liu, J., & Lin, Y. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.09.004 · Cited by 1,229
Pinson, J., & Podvorica, F. (2005) · Chemical Society Reviews · doi:10.1039/b406228k · Cited by 1,193
Application of graphene-modified electrode for selective detection of dopamine
Wang, Y., Li, Y., Tang, L., Lu, J., & Li, J. (2009) · Electrochemistry Communications · doi:10.1016/j.elecom.2009.02.013 · Cited by 1,117
Chen, S., Zheng, J., Li, L., & Jiang, S. (2005) · Journal of the American Chemical Society · doi:10.1021/ja054169u · Cited by 1,038
Electrografting: a powerful method for surface modification
Bélanger, D., & Pinson, J. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00149j · Cited by 980
Atom Transfer Radical Polymerization and the Synthesis of Polymeric Materials
Patten, T. E., & Matyjaszewski, K. (1998) · Advanced Materials · doi:10.1002/(sici)1521-4095(199808)10:12<901::aid-adma901>3.0.co;2-b · Cited by 896
Glucose Biosensors Based on Carbon Nanotube Nanoelectrode Ensembles
Lin, Y., Lu, F., Tu, Y., & Ren, Z. (2004) · Nano Letters · doi:10.1021/nl0347233 · Cited by 895
Zwitterionic SAMs that Resist Nonspecific Adsorption of Protein from Aqueous Buffer
Holmlin, R. E., Chen, X., Chapman, R. G., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la0015258 · Cited by 891
Poly(2‐oxazoline)s: A Polymer Class with Numerous Potential Applications
Hoogenboom, R. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200901607 · Cited by 889
Highly Sensitive Glucose Sensor Based on Pt Nanoparticle/Polyaniline Hydrogel Heterostructures
Zhai, D., Liu, B., Shi, Y., Pan, L., Wang, Y., Li, W., Zhang, R., & Yu, G. (2013) · ACS Nano · doi:10.1021/nn400482d · Cited by 814
Shang, N. G., Papakonstantinou, P., McMullan, M., Chu, M., Stamboulis, A., Potenza, A., Dhesi, S. S., & Marchetto, H. (2008) · Advanced Functional Materials · doi:10.1002/adfm.200800951 · Cited by 812
Ladd, J., Zhang, Z., Chen, S., Hower, J. C., & Jiang, S. (2008) · Biomacromolecules · doi:10.1021/bm701301s · Cited by 808
Hydrogels in sensing applications
Buenger, D., Topuz, F., & Groll, J. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.09.001 · Cited by 762
Blood compatibility of polyethylene oxide surfaces
LEE, J., LEE, H., & ANDRADE, J. (1995) · Progress in Polymer Science · doi:10.1016/0079-6700(95)00011-4 · Cited by 703
Wang, Z., Zhou, X., Zhang, J., Boey, F., & Zhang, H. (2009) · The Journal of Physical Chemistry C · doi:10.1021/jp906348x · Cited by 684
Ma, H., Hyun, J., Stiller, P., & Chilkoti, A. (2004) · Advanced Materials · doi:10.1002/adma.200305830 · Cited by 680
Probing the Electrochemical Properties of Graphene Nanosheets for Biosensing Applications
Alwarappan, S., Erdem, A., Liu, C., & Li, C.-Z. (2009) · The Journal of Physical Chemistry C · doi:10.1021/jp9010313 · Cited by 616
Antifouling Strategies for Selective In Vitro and In Vivo Sensing
Jiang, C., Wang, G., Hein, R., Liu, N., Luo, X., & Davis, J. J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00739 · Cited by 598
Electrochemically assisted self-assembly of mesoporous silica thin films
Walcarius, A., Sibottier, E., Etienne, M., & Ghanbaja, J. (2007) · Nature Materials · doi:10.1038/nmat1951 · Cited by 580
Antibiofouling polymer interfaces: poly(ethylene glycol) and other promising candidates
Lowe, S., O'Brien-Simpson, N. M., & Connal, L. A. (2015) · Polymer Chemistry · doi:10.1039/c4py01356e · Cited by 557
Boundary lubrication of articular cartilage: Role of synovial fluid constituents
Schmidt, T. A., Gastelum, N. S., Nguyen, Q. T., Schumacher, B. L., & Sah, R. L. (2007) · Arthritis & Rheumatism · doi:10.1002/art.22446 · Cited by 554
In Pursuit of Zero: Polymer Brushes that Resist the Adsorption of Proteins
Hucknall, A., Rangarajan, S., & Chilkoti, A. (2009) · Advanced Materials · doi:10.1002/adma.200900383 · Cited by 552
Zwitterionic carboxybetaine polymer surfaces and their resistance to long-term biofilm formation
Cheng, G., Li, G., Xue, H., Chen, S., Bryers, J. D., & Jiang, S. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.05.058 · Cited by 523
Sabaté del Río, J., Henry, O. Y. F., Jolly, P., & Ingber, D. E. (2019) · Nature Nanotechnology · doi:10.1038/s41565-019-0566-z · Cited by 450
Hydrogel Based Sensors for Biomedical Applications: An Updated Review
Tavakoli, J., & Tang, Y. (2017) · Polymers · doi:10.3390/polym9080364 · Cited by 434
Carbon nanotubes paste electrode
Rubianes, M. D., & Rivas, G. A. (2003) · Electrochemistry Communications · doi:10.1016/s1388-2481(03)00168-1 · Cited by 434
Protein Adsorption on Surfaces with Grafted Polymers
Szleifer, I. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78698-3 · Cited by 427
A Nanostructured Conductive Hydrogels-Based Biosensor Platform for Human Metabolite Detection
Li, L., Wang, Y., Pan, L., Shi, Y., Cheng, W., Shi, Y., & Yu, G. (2015) · Nano Letters · doi:10.1021/nl504217p · Cited by 422
Luo, X.-L., Xu, J.-J., Du, Y., & Chen, H.-Y. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2004.07.005 · Cited by 397
Teng, Z., Zheng, G., Dou, Y., Li, W., Mou, C., Zhang, X., Asiri, A. M., & Zhao, D. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201108748 · Cited by 383
Covalent Attachment of Poly(ethylene glycol) to Surfaces, Critical for Reducing Bacterial Adhesion
Kingshott, P., Wei, J., Bagge-Ravn, D., Gadegaard, N., & Gram, L. (2003) · Langmuir · doi:10.1021/la034032m · Cited by 369
The biology of Lubricin: Near frictionless joint motion
Jay, G. D., & Waller, K. A. (2014) · Matrix Biology · doi:10.1016/j.matbio.2014.08.008 · Cited by 341
Ultra-low fouling peptide surfaces derived from natural amino acids
Chen, S., Cao, Z., & Jiang, S. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.07.001 · Cited by 335
Fabrication of Corona-Free Nanoparticles with Tunable Hydrophobicity
Moyano, D. F., Saha, K., Prakash, G., Yan, B., Kong, H., Yazdani, M., & Rotello, V. M. (2014) · ACS Nano · doi:10.1021/nn5006478 · Cited by 331
Cao, Z., & Jiang, S. (2012) · Nano Today · doi:10.1016/j.nantod.2012.08.001 · Cited by 329
Sequence, Structure, and Function of Peptide Self-Assembled Monolayers
Nowinski, A. K., Sun, F., White, A. D., Keefe, A. J., & Jiang, S. (2012) · Journal of the American Chemical Society · doi:10.1021/ja3006868 · Cited by 326
Poly(2‐Oxazoline)s – Are They More Advantageous for Biomedical Applications Than Other Polymers?
Sedlacek, O., Monnery, B. D., Filippov, S. K., Hoogenboom, R., & Hruby, M. (2012) · Macromolecular Rapid Communications · doi:10.1002/marc.201200453 · Cited by 312
Pursuing “Zero” Protein Adsorption of Poly(carboxybetaine) from Undiluted Blood Serum and Plasma
Yang, W., Xue, H., Li, W., Zhang, J., & Jiang, S. (2009) · Langmuir · doi:10.1021/la9015788 · Cited by 305
Amperometric Glucose Biosensor Based on Sol−Gel Organic−Inorganic Hybrid Material
Wang, B., Li, B., Deng, Q., & Dong, S. (1998) · Analytical Chemistry · doi:10.1021/ac980160h · Cited by 299
Antifouling strategies in advanced electrochemical sensors and biosensors
Lin, P.-H., & Li, B. (2019) · The Analyst · doi:10.1039/c9an02017a · Cited by 287
Interaction of Blood Plasma with Antifouling Surfaces
Rodriguez‐Emmenegger, C., Brynda, E., Riedel, T., Sedláková, Z., Houška, M., & Alles, A. B. (2009) · Langmuir · doi:10.1021/la900083s · Cited by 283
Trewyn, B. G., Nieweg, J. A., Zhao, Y., & Lin, V. S.-Y. (2008) · Chemical Engineering Journal · doi:10.1016/j.cej.2007.09.045 · Cited by 275
Carbon nanofiber based electrochemical biosensors: A review
Huang, J., Liu, Y., & You, T. (2010) · Analytical Methods · doi:10.1039/b9ay00312f · Cited by 272
Carbon Nanotube−Ionic Liquid Composite Sensors and Biosensors
Kachoosangi, R. T., Musameh, M. M., Abu-Yousef, I., Yousef, J. M., Kanan, S. M., Xiao, L., Davies, S. G., Russell, A., & Compton, R. G. (2009) · Analytical Chemistry · doi:10.1021/ac801853r · Cited by 267
Reusable Impedimetric Aptasensor
Radi, A.-E., Acero Sánchez, J. L., Baldrich, E., & O'Sullivan, C. K. (2005) · Analytical Chemistry · doi:10.1021/ac0505775 · Cited by 266
Polyoxazolines for Nonfouling Surface Coatings — A Direct Comparison to the Gold Standard PEG
Konradi, R., Acikgoz, C., & Textor, M. (2012) · Macromolecular Rapid Communications · doi:10.1002/marc.201200422 · Cited by 264
Salimi, A., Compton, R. G., & Hallaj, R. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2004.06.039 · Cited by 257
Electrochemical Interrogation of DNA Monolayers on Gold Surfaces
Lao, R., Song, S., Wu, H., Wang, L., Zhang, Z., He, L., & Fan, C. (2005) · Analytical Chemistry · doi:10.1021/ac050911x · Cited by 250
Boundary lubrication by lubricin is mediated by O-linked β(1-3)Gal-GalNAc oligosaccharides
Jay, G. D., Harris, D. A., & Cha, C.-J. (2001) · Glycoconjugate Journal · doi:10.1023/a:1021159619373 · Cited by 248
Yang, W., Zhang, L., Wang, S., White, A. D., & Jiang, S. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.06.036 · Cited by 242
Teng, Z., Zheng, G., Dou, Y., Li, W., Mou, C., Zhang, X., Asiri, A. M., & Zhao, D. (2012) · Angewandte Chemie · doi:10.1002/ange.201108748 · Cited by 235
Tugulu, S., & Klok, H.-A. (2008) · Biomacromolecules · doi:10.1021/bm701293g · Cited by 233
Surface engineering strategies for control of protein and cell interactions
Nath, N., Hyun, J., Ma, H., & Chilkoti, A. (2004) · Surface Science · doi:10.1016/j.susc.2004.06.182 · Cited by 232
Strong Resistance of a Thin Crystalline Layer of Balanced Charged Groups to Protein Adsorption
Chen, S., Yu, F., Yu, Q., He, Y., & Jiang, S. (2006) · Langmuir · doi:10.1021/la061012m · Cited by 228
Hui, N., Sun, X., Niu, S., & Luo, X. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b11682 · Cited by 227
Smith, R. S., Zhang, Z., Bouchard, M., Li, J., Lapp, H. S., Brotske, G. R., Lucchino, D. L., Weaver, D., Roth, L. A., Coury, A., et al. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004120 · Cited by 221
Oriented Mesoporous Silica Films Obtained by Electro-Assisted Self-Assembly (EASA)
Goux, A., Etienne, M., Aubert, E., Lecomte, C., Ghanbaja, J., & Walcarius, A. (2009) · Chemistry of Materials · doi:10.1021/cm8029664 · Cited by 212
Lu, J., Drzal, L. T., Worden, R. M., et al. (2007) · Chemistry of Materials · doi:10.1021/cm702133u · Cited by 203
Rapid 3D Patterning of Poly(acrylic acid) Ionic Hydrogel for Miniature pH Sensors
Yin, M., Yao, M., Gao, S., Zhang, A. P., Tam, H., & Wai, P. A. (2016) · Advanced Materials · doi:10.1002/adma.201504021 · Cited by 190
Antifouling (Bio)materials for Electrochemical (Bio)sensing
Campuzano, S., Pedrero, M., Yáñez-Sedeño, P., & Pingarrón, J. M. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20020423 · Cited by 181
Electrochemical Properties of Nanostructured Porous Gold Electrodes in Biofouling Solutions
Patel, J., Radhakrishnan, L., Zhao, B., Uppalapati, B., Daniels, R. C., Ward, K. R., & Collinson, M. M. (2013) · Analytical Chemistry · doi:10.1021/ac403013r · Cited by 172
Zhou, M., Shang, L., Li, B., Huang, L., & Dong, S. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.04.025 · Cited by 168
Nanoporous anti-fouling silicon membranes for biosensor applications
Desai, T. A., Hansford, D. J., Leoni, L., Essenpreis, M., & Ferrari, M. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00088-9 · Cited by 163
Tegoulia, V. A., Rao, W., Kalambur, A. T., Rabolt, J. F., & Cooper, S. L. (2001) · Langmuir · doi:10.1021/la001790t · Cited by 159
Reis, R. F., de Melo Quintela, B., de Oliveira Campos, J., Gomes, J. M., Rocha, B. M., Lobosco, M., & Weber dos Santos, R. (2020) · Chaos, Solitons & Fractals · doi:10.1016/j.chaos.2020.109888 · Cited by 159
Brahim, S. I., Narinesingh, D., & Guiseppi‐Elie, A. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00089-1 · Cited by 156
Chapman, C. A. R., Chen, H., Stamou, M., Biener, J., Biener, M. M., Lein, P. J., & Şeker, E. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b00410 · Cited by 151
Poly(2-oxazoline) functionalized surfaces: from modification to application
Tauhardt, L., Kempe, K., Gottschaldt, M., & Schubert, U. S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60161g · Cited by 149
Sanaeifar, N., Rabiee, M., Abdolrahim, M., Tahriri, M., Vashaee, D., & Tayebi, L. (2016) · Analytical Biochemistry · doi:10.1016/j.ab.2016.12.006 · Cited by 146
Antifouling Glycocalyx-Mimetic Peptoids
Ham, H. O., Park, S. H., Kurutz, J. W., Szleifer, I. G., & Messersmith, P. B. (2013) · Journal of the American Chemical Society · doi:10.1021/ja404681x · Cited by 139
Zhang, H., Meng, Z., Wang, Q., & Zheng, J. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.04.057 · Cited by 137
Cui, M., Song, Z., Wu, Y., Guo, B., Fan, X., & Luo, X. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.01.012 · Cited by 135
Riedel, T., Reicheltová, Z., Májek, P., Rodriguez‐Emmenegger, C., Houška, M., Dyr, J. E., & Brynda, E. (2013) · Langmuir · doi:10.1021/la304886r · Cited by 134
Methods for the measurement of benzodiazepines in biological samples
Drummer, O. H. (1998) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(97)00537-9 · Cited by 133
Peptide‐Based Approaches to Fight Biofouling
Sakala, G. P., & Reches, M. (2018) · Advanced Materials Interfaces · doi:10.1002/admi.201800073 · Cited by 132
Nanocomposite film based on graphene oxide for high performance flexible glucose biosensor
Qiu, J., Huang, J., & Liang, R. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.07.049 · Cited by 128
Decoding nonspecific interactions from nature
White, A. D., Nowinski, A. K., Huang, W., Keefe, A. J., Sun, F., & Jiang, S. (2012) · Chemical Science · doi:10.1039/c2sc21135a · Cited by 127
Effect of Nanoporous Gold Thin Film Morphology on Electrochemical DNA Sensing
Daggumati, P., Matharu, Z., & Şeker, E. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00846 · Cited by 116
Lubricin: A versatile, biological anti-adhesive with properties comparable to polyethylene glycol
Greene, G. W., Martin, L. L., Tabor, R. F., Michalczyk, A. A., Ackland, M. L., & Horn, R. G. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.086 · Cited by 112
Self-citationLiu, N., Hui, N., Davis, J. J., & Luo, X. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00318 · Cited by 104
Jiang, C., Alam, M. T., Silva, S. M., Taufik, S., Fan, S., & Gooding, J. J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00532 · Cited by 102
Self-citationGui, A. L., Luais, E., Peterson, J. R., & Gooding, J. J. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am400519m · Cited by 99
Matharu, Z., Daggumati, P., Wang, L., Dorofeeva, T. S., Li, Z., & Şeker, E. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b15212 · Cited by 97
Reiter, S., Habermüller, K., & Schuhmann, W. W. (2001) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00861-9 · Cited by 91
Lubricin and surfacing of articular joints
Jay, G. D. (2004) · Current Opinion in Orthopedics · doi:10.1097/01.bco.0000136127.00043.a8 · Cited by 87
A comparison of the adsorption of three adhesive proteins to biomaterial surfaces
Fabrizius‐Homan, D. J., & Cooper, S. L. (1992) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856292x00060 · Cited by 86
Habibi, B., & Jahanbakhshi, M. (2013) · Electrochimica Acta · doi:10.1016/j.electacta.2013.11.169 · Cited by 77
Das, J., & Sarkar, P. (2016) · RSC Advances · doi:10.1039/c6ra12159d · Cited by 75
Veerapandian, M., Seo, Y.-T., Yun, K., & Lee, M. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.02.062 · Cited by 72
Delayed Sensor Activation Based on Transient Coatings: Biofouling Protection in Complex Biofluids
Montiel, V. R., Sempionatto, J. R., de Ávila, B. E., Whitworth, A., Campuzano, S., Pingarrón, J. M., & Wang, J. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b08894 · Cited by 69
Wu, S., Su, F., Dong, X., Ma, C., Pang, L., Peng, D., Wang, M., He, L., & Zhang, Z. (2017) · Applied Surface Science · doi:10.1016/j.apsusc.2017.01.024 · Cited by 67
Direct electrochemical biosensing in gastrointestinal fluids
Montiel, V. R., Sempionatto, J. R., Campuzano, S., Pingarrón, J. M., de Ávila, B. E., & Wang, J. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1528-2 · Cited by 63
PEGMA/MMA Copolymer Graftings: Generation, Protein Resistance, and a Hydrophobic Domain
Stadler, V., Kirmse, R., Beyer, M., Breitling, F., Ludwig, T. E., & Bischoff, F. R. (2008) · Langmuir · doi:10.1021/la800772m · Cited by 62
Zhou, L., Ding, H., Yan, F., Guo, W., & Su, B. (2018) · The Analyst · doi:10.1039/c8an01457d · Cited by 62
Silva, T. A., Khan, M. R. K., Fatibello‐Filho, O., & Collinson, M. M. (2019) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2019.05.042 · Cited by 61
Haustein, N., Gutiérrez‐Sanz, Ó., & Tarasov, A. (2019) · ACS Sensors · doi:10.1021/acssensors.8b01515 · Cited by 56
Resistance of Zwitterionic Peptide Monolayers to Biofouling
Ederth, T., Lerm, M., Orihuela, B., & Rittschof, D. (2018) · Langmuir · doi:10.1021/acs.langmuir.8b01625 · Cited by 53
Enhanced Glucose Sensor Linearity Using Poly(Vinyl Alcohol) Hydrogels
Vaddiraju, S., Singh, H., Burgess, D. J., Jain, F., & Papadimitrakopoulos, F. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300434 · Cited by 49
Screening nonspecific interactions of peptides without background interference
Keefe, A. J., Caldwell, K. B., Nowinski, A. K., White, A. D., Thakkar, A., & Jiang, S. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.11.014 · Cited by 47
Structure and Property Changes in Self-Assembled Lubricin Layers Induced by Calcium Ion Interactions
Greene, G. W., Thapa, R., Holt, S. A., Wang, X., Garvey, C. J., & Tabor, R. F. (2017) · Langmuir · doi:10.1021/acs.langmuir.6b03992 · Cited by 47
Self-citationPolymeric nanocapsules ultra stable in complex biological media
Rodriguez‐Emmenegger, C., Jäger, A., Jäger, E., Štěpánek, P., Alles, A. B., Guterres, S. S., Pohlmann, A. R., & Brynda, E. (2010) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2010.12.013 · Cited by 46
Greene, G. W., Ortiz, V., Pozo‐Gonzalo, C., Moulton, S. E., Wang, X., Martin, L. L., Michalczky, A., & Howlett, P. C. (2018) · Advanced Materials Interfaces · doi:10.1002/admi.201701296 · Cited by 46
Self-citationdos Santos, W. T. P., & Compton, R. G. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.01.047 · Cited by 45
Russo, M. J., Quigley, A. F., Kapsa, R. M. I., Moulton, S. E., Guijt, R. M., Silva, S. M., & Greene, G. W. (2020) · ChemElectroChem · doi:10.1002/celc.202000393 · Cited by 37
Self-citationMa, L., Jayachandran, S., Li, Z., Song, Z., Wang, W., & Luo, X. (2019) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2019.04.002 · Cited by 36
Lubricin: A novel means to decrease bacterial adhesion and proliferation
Aninwene, G. E., Abadian, P. N., Ravi, V., Taylor, E. N., Hall, D. M., Mei, A., Jay, G. D., Goluch, E. D., & Webster, T. J. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35195 · Cited by 35
Poly(ethylene glycol)-based biosensor chip to study heparin–protein interactions
Munoz, E. M., Yu, H., Hallock, J., Edens, R. E., & Linhardt, R. J. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2005.04.031 · Cited by 34
Silva, S. M., Quigley, A. F., Kapsa, R. M. I., Greene, G. W., & Moulton, S. E. (2019) · ChemElectroChem · doi:10.1002/celc.201900237 · Cited by 32
Self-citationInvestigation of the Antifouling Properties of Phenyl Phosphorylcholine‐Based Modified Gold Surfaces
Parviz, M., Darwish, N. A., Alam, M. T., Parker, S. G., Ciampi, S., & Gooding, J. J. (2014) · Electroanalysis · doi:10.1002/elan.201400102 · Cited by 31
Choudhary, M., van den Brink, R. W. C., Nandi, D., Siwal, S. S., & Mallick, K. (2016) · Journal of Materials Science · doi:10.1007/s10853-016-0372-z · Cited by 31
Homma, T., Sumita, D., Kondo, M., Kuwahara, T., & Shimomura, M. (2013) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2013.11.009 · Cited by 30
Platinized Silica Nanoporous Membrane Electrodes for Low‐Fouling Hydrogen Peroxide Detection
Li, X., Zhou, L., Ding, J., Sun, L., & Su, B. (2020) · ChemElectroChem · doi:10.1002/celc.202000321 · Cited by 29
Jiang, C., Alam, M. T., Parker, S. G., & Gooding, J. J. (2015) · Electroanalysis · doi:10.1002/elan.201400557 · Cited by 26
Electrokinetic Properties of Lubricin Antiadhesive Coatings in Microfluidic Systems
Greene, G. W., Duffy, E., Shallan, A. I., Wuethrich, A., & Paull, B. (2016) · Langmuir · doi:10.1021/acs.langmuir.5b03535 · Cited by 26
Self-citationSu, X., Wei, J., Ren, X., Li, L., Meng, X., Ren, J., & Tang, F. (2013) · Journal of Biomedical Nanotechnology · doi:10.1166/jbn.2013.1671 · Cited by 20
PEGylation of platinum bio-electrodes
Yue, Z., Molino, P. J., Liu, X., et al. (2012) · Electrochemistry Communications · doi:10.1016/j.elecom.2012.11.007 · Cited by 18
Binazadeh, M., Faghihnejad, A., Unsworth, L. D., et al. (2013) · Biomacromolecules · doi:10.1021/bm400837t · Cited by 18
Cited by
Dong, T., Matos Pires, N. M., Yang, Z., & Jiang, Z. (2023) · Advanced Science · doi:10.1002/advs.202205429 · Cited by 104
Metadata
- Authors
- Russo, M. J., Han, M., Desroches, P. E., Manasa, C. S., Dennaoui, J., Quigley, A. F., Kapsa, R. M. I., Moulton, S. E., Guijt, R. M., Greene, G. W., & Silva, S. M.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-03-25
- Volume
- 6
- Issue
- 4
- Pages
- 1482-1507
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W3138428755
- Cited by
- 338
- References
- 123
- FWCI
- 11.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.