The DOI matches its Crossref record; 122 of the 122 references it cites were found in a registry or an index.
Surface Plasmon Resonance Clinical Biosensors for Medical Diagnostics
Abstract
The design and application of sensors for monitoring biomolecules in clinical samples is a common goal of the sensing research community. Surface plasmon resonance (SPR) and other plasmonic techniques such as localized surface plasmon resonance (LSPR) and imaging SPR are reaching a maturity level sufficient for their application in monitoring biomolecules in clinical samples. In recent years, the first examples for monitoring antibodies, proteins, enzymes, drugs, small molecules, peptides, and nucleic acids in biofluids collected from patients afflicted with a series of medical conditions (Alzheimer's, hepatitis, diabetes, leukemia, and cancers such as prostate and breast cancers, among others) demonstrate the progress of SPR sensing in clinical chemistry. This Perspective reviews the current status of the field, showcasing a series of early successes in the application of SPR for clinical analysis and detailing a series of considerations regarding sensing schemes, exposing issues with analysis in biofluids, and comparing SPR with ELISA, while providing an outlook of the challenges currently associated with plasmonic materials, instrumentation, microfluidics, bioreceptor selection, selection of a clinical market, and validation of a clinical assay for applying SPR sensors to clinical samples. Research opportunities are proposed to further advance the field and transition SPR biosensors from research proof-of-concept stage to actual clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface Plasmon Resonance Sensors for Detection of Chemical and Biological Species
Homola, J. (2008) · Chemical Reviews · doi:10.1021/cr068107d · Cited by 4,525
Haynes, C. L., & Van Duyne, R. P. (2001) · The Journal of Physical Chemistry B · doi:10.1021/jp010657m · Cited by 2,500
Shape Control of Colloidal Metal Nanocrystals
Tao, A. R., Habas, S., & Yang, P. (2008) · Small · doi:10.1002/smll.200701295 · Cited by 2,408
Gold nanostructures: engineering their plasmonic properties for biomedical applications
Hu, M., Chen, J., Li, Z.-Y., Au, L., Hartland, G. V., Li, X., Marquez, M., & Xia, Y. (2006) · Chemical Society Reviews · doi:10.1039/b517615h · Cited by 1,756
Localized surface plasmon resonance: Nanostructures, bioassays and biosensing—A review
Petryayeva, E., & Krull, U. J. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.08.020 · Cited by 1,379
Label-free detection and molecular profiling of exosomes with a nano-plasmonic sensor
Im, H., Shao, H., Park, Y. I., Peterson, V. M., Castro, C. M., Weissleder, R., & Lee, H. (2014) · Nature Biotechnology · doi:10.1038/nbt.2886 · Cited by 1,321
Nanomaterials enhanced surface plasmon resonance for biological and chemical sensing applications
Zeng, S., Baillargeat, D., Ho, H.-P., & Yong, K.-T. (2014) · Chemical Society Reviews · doi:10.1039/c3cs60479a · Cited by 1,230
A fiber-optic chemical sensor based on surface plasmon resonance
Jorgenson, R. C., & Yee, S. S. (1993) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(93)80021-3 · Cited by 1,229
Plasmon-enhanced optical sensors: a review
Li, M., Cushing, S. K., & Wu, N. (2015) · The Analyst · doi:10.1039/c4an01079e · Cited by 1,011
Long-range surface plasmon polaritons
Berini, P. (2009) · Advances in Optics and Photonics · doi:10.1364/aop.1.000484 · Cited by 996
Colloidal Au-Enhanced Surface Plasmon Resonance for Ultrasensitive Detection of DNA Hybridization
He, L., Musick, M. D., Nicewarner, S. R., Salinas, F. G., Benkovic, S. J., Natan, M. J., & Keating, C. D. (2000) · Journal of the American Chemical Society · doi:10.1021/ja001215b · Cited by 932
Haes, A. J., Chang, L., Klein, W. L., & Van Duyne, R. P. (2005) · Journal of the American Chemical Society · doi:10.1021/ja044087q · Cited by 864
Microfluidics-based diagnostics of infectious diseases in the developing world
Chin, C. D., Laksanasopin, T., Cheung, Y. K., Steinmiller, D., Linder, V., Parsa, H., Wang, J., Moore, H., Rouse, R., Umviligihozo, G., et al. (2011) · Nature Medicine · doi:10.1038/nm.2408 · Cited by 759
The nanoparticle biomolecule corona: lessons learned – challenge accepted?
Docter, D., Westmeier, D., Markiewicz, M., Stolte, S., Knauer, S. K., & Stauber, R. H. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00217f · Cited by 693
Nelson, B. P., Grimsrud, T. E., Liles, M. R., Goodman, R. M., & Corn, R. M. (2001) · Analytical Chemistry · doi:10.1021/ac0010431 · Cited by 652
Localized Surface Plasmon Resonance Biosensing: Current Challenges and Approaches
Unser, S., Bruzas, I., He, J., & Sagle, L. (2015) · Sensors · doi:10.3390/s150715684 · Cited by 565
Measurement of biomarker proteins for point-of-care early detection and monitoring of cancer
Rusling, J. F., Kumar, C. V., Gutkind, J. S., & Patel, V. (2010) · The Analyst · doi:10.1039/c0an00204f · Cited by 552
Wackerlig, J., & Lieberzeit, P. A. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.09.094 · Cited by 485
Fang, S., Lee, H. J., Wark, A. W., & Corn, R. M. (2006) · Journal of the American Chemical Society · doi:10.1021/ja065223p · Cited by 450
Surface plasmon resonance imaging for affinity-based biosensors
Scarano, S., Mascini, M., Turner, A. P. F., & Minunni, M. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.08.039 · Cited by 426
Strategies for enhancing the sensitivity of plasmonic nanosensors
Guo, L., Jackman, J. A., Yang, H.-H., Chen, P., Cho, N.-J., & Kim, D.-H. (2015) · Nano Today · doi:10.1016/j.nantod.2015.02.007 · Cited by 415
Vaisocherová, H., Yang, W., Zhang, Z., Cao, Z., Cheng, G., Piliarik, M., Homola, J., & Jiang, S. (2008) · Analytical Chemistry · doi:10.1021/ac8015888 · Cited by 409
Immunoassays in microfluidic systems
Ng, A. H. C., Uddayasankar, U., & Wheeler, A. R. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3678-8 · Cited by 345
Point-of-care biochemical assays using gold nanoparticle-implemented microfluidics
Sun, J., Xianyu, Y., & Jiang, X. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00125g · Cited by 323
Plasmonic Nanostructures for Nano-Scale Bio-Sensing
Chung, T., Lee, S., Song, E. Y., Chun, H., & Lee, B. (2011) · Sensors · doi:10.3390/s111110907 · Cited by 323
Multiplex Serum Cytokine Immunoassay Using Nanoplasmonic Biosensor Microarrays
Chen, P., Chung, M. T., McHugh, W., Nidetz, R., Li, Y., Fu, J., Cornell, T. T., Shanley, T. P., & Kurabayashi, K. (2015) · ACS Nano · doi:10.1021/acsnano.5b00396 · Cited by 321
LSPR Chip for Parallel, Rapid, and Sensitive Detection of Cancer Markers in Serum
Aćimović, S. S., Ortega, M. A., Sanz, V., Berthelot, J., Garcia-Cordero, J. L., Renger, J., Maerkl, S. J., Kreuzer, M. P., & Quidant, R. (2014) · Nano Letters · doi:10.1021/nl500574n · Cited by 310
Paper-based analytical devices for environmental analysis
Meredith, N. A., Quinn, C., Cate, D. M., Reilly, T. H., Volckens, J., & Henry, C. S. (2016) · The Analyst · doi:10.1039/c5an02572a · Cited by 299
Uludag, Y., & Tothill, I. E. (2012) · Analytical Chemistry · doi:10.1021/ac300278p · Cited by 290
Point-of-care immunotesting: Approaching the analytical performance of central laboratory methods
von Lode, P. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2005.03.008 · Cited by 290
Interaction of Blood Plasma with Antifouling Surfaces
Rodriguez‐Emmenegger, C., Brynda, E., Riedel, T., Sedláková, Z., Houška, M., & Alles, A. B. (2009) · Langmuir · doi:10.1021/la900083s · Cited by 283
Surface chemistry to minimize fouling from blood-based fluids
Blaszykowski, C., Sheikh, S., & Thompson, M. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35170f · Cited by 271
Surface plasmon resonance applications in clinical analysis
Mariani, S., & Minunni, M. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7647-5 · Cited by 231
Ilgu, M., & Nilsen-Hamilton, M. (2016) · The Analyst · doi:10.1039/c5an01824b · Cited by 231
Recent approaches for optical smartphone sensing in resource-limited settings: a brief review
McCracken, K. E., & Yoon, J.-Y. (2016) · Analytical Methods · doi:10.1039/c6ay01575a · Cited by 216
Aptamers Facilitating Amplified Detection of Biomolecules
Li, F., Zhang, H., Wang, Z., Newbigging, A. M., Reid, M. S., Li, X.-F., & Le, X. C. (2015) · Analytical Chemistry · doi:10.1021/ac5037236 · Cited by 207
Ertürk, G., Özen, H., Tümer, M. A., Mattiasson, B., & Denizli, A. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.10.093 · Cited by 206
Comparing ELISA and Surface Plasmon Resonance for Assessing Clinical Immunogenicity of Panitumumab
Lofgren, J. A., Dhandapani, S., Pennucci, J. J., Abbott, C. M., Mytych, D. T., Kaliyaperumal, A., Swanson, S. J., & Mullenix, M. C. (2007) · The Journal of Immunology · doi:10.4049/jimmunol.178.11.7467 · Cited by 197
Vaisocherová, H., Zhang, Z., Yang, W., Cao, Z., Cheng, G., Taylor, A. D., Piliarik, M., Homola, J., & Jiang, S. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.09.035 · Cited by 194
Trends in aptamer selection methods and applications
Yüce, M., Ullah, N., & Budak, H. (2015) · The Analyst · doi:10.1039/c5an00954e · Cited by 193
Nanoplasmonic Quantitative Detection of Intact Viruses from Unprocessed Whole Blood
Inci, F., Tokel, O., Wang, S., Gurkan, U. A., Tasoglu, S., Kuritzkes, D. R., & Demirci, U. (2013) · ACS Nano · doi:10.1021/nn3036232 · Cited by 182
Magnetic Nanoparticle-Enhanced Biosensor Based on Grating-Coupled Surface Plasmon Resonance
Wang, Y., Dostalek, J., & Knoll, W. (2011) · Analytical Chemistry · doi:10.1021/ac200751s · Cited by 176
Modern surface plasmon resonance for bioanalytics and biophysics
Couture, M., Zhao, S. S., & Masson, J.-F. (2013) · Physical Chemistry Chemical Physics · doi:10.1039/c3cp50281c · Cited by 173
Self-citationVaisocherová, H., Brynda, E., & Homola, J. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-8606-5 · Cited by 161
Smartphone spectrometer for colorimetric biosensing
Wang, Y., Liu, X., Chen, P., Tran, N. T., Zhang, J., Chia, W. S., Boujday, S., & Liedberg, B. (2016) · The Analyst · doi:10.1039/c5an02508g · Cited by 151
Surface Plasmon Resonance Biosensors Incorporating Gold Nanoparticles
Bedford, E. E., Spadavecchia, J., Pradier, C., & Gu, F. (2012) · Macromolecular Bioscience · doi:10.1002/mabi.201100435 · Cited by 148
SPR Biosensing in Crude Serum Using Ultralow Fouling Binary Patterned Peptide SAM
Bolduc, O. R., Pelletier, J. N., & Masson, J. (2010) · Analytical Chemistry · doi:10.1021/ac100035s · Cited by 138
Self-citationLabel-Free Detection of Tobramycin in Serum by Transmission-Localized Surface Plasmon Resonance
Cappi, G., Spiga, F. M., Moncada, Y., Ferretti, A. M., Beyeler, M. J., Bianchessi, M. A., Decosterd, L. A., Buclin, T., & Guiducci, C. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00389 · Cited by 138
Miniature multi-channel SPR instrument for methotrexate monitoring in clinical samples
Zhao, S. S., Bukar, N., Toulouse, J. L., Pelechacz, D., Robitaille, R., Pelletier, J. N., & Masson, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.082 · Cited by 138
Self-citationFrasconi, M., Tortolini, C., Botrè, F., & Mazzei, F. (2010) · Analytical Chemistry · doi:10.1021/ac101319k · Cited by 137
Xia, N., Liu, L., Harrington, M. G., Wang, J., & Zhou, F. (2010) · Analytical Chemistry · doi:10.1021/ac102257m · Cited by 136
Rapid Immunoglobulin M-Based Dengue Diagnostic Test Using Surface Plasmon Resonance Biosensor
Jahanshahi, P., Zalnezhad, E., Sekaran, S. D., & Adikan, F. R. M. (2014) · Scientific Reports · doi:10.1038/srep03851 · Cited by 127
Aptamers: versatile molecular recognition probes for cancer detection
Sun, H., Tan, W., & Zu, Y. (2015) · The Analyst · doi:10.1039/c5an01995h · Cited by 120
Wang, Q., Liu, R., Yang, X., Wang, K., Zhu, J., He, L., & Li, Q. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.09.152 · Cited by 119
Quantification of Cytokines Involved in Wound Healing Using Surface Plasmon Resonance
Battaglia, T. M., Masson, J., Sierks, M. R., Beaudoin, S. P., Rogers, J. M., Foster, K. N., Holloway, G. A., & Booksh, K. S. (2005) · Analytical Chemistry · doi:10.1021/ac050568w · Cited by 115
Self-citationSmartphone based LSPR sensing platform for bio-conjugation detection and quantification
Dutta, S., Saikia, K., & Nath, P. (2016) · RSC Advances · doi:10.1039/c6ra01113f · Cited by 112
Li, J., Lei, P., Ding, S., Zhang, Y., Yang, J., Cheng, Q. J., & Yan, Y. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.09.069 · Cited by 107
Biosensors and nanobiosensors for therapeutic drug and response monitoring
McKeating, K. S., Aubé, A., & Masson, J. (2015) · The Analyst · doi:10.1039/c5an01861g · Cited by 107
Self-citationZhang, Y., McKelvie, I. D., Cattrall, R. W., & Kolev, S. D. (2016) · Talanta · doi:10.1016/j.talanta.2016.02.015 · Cited by 106
Yuan, J., Duan, Yang, Luo, & Xi, M. (2012) · International Journal of Nanomedicine · doi:10.2147/ijn.s32641 · Cited by 104
Brault, N. D., Gao, C., Xue, H., Piliarik, M., Homola, J., Jiang, S., & Yu, Q. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.03.012 · Cited by 103
Chou, S.-F., Hsu, W.-L., Hwang, J., & Chen, C. (2003) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.09.004 · Cited by 101
Vaisocherová‐Lísalová, H., Šípová, H., Víšová, I., Bocková, M., Špringer, T., Ermini, M. L., Song, X., Krejčík, Z., Chrastinová, L., Pastva, O., et al. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.03.038 · Cited by 96
Tuning the 3D plasmon field of nanohole arrays
Couture, M., Liang, Y., Poirier-Richard, H.-P., Faid, R., Peng, W. B., & Masson, J. (2013) · Nanoscale · doi:10.1039/c3nr04002j · Cited by 87
Self-citationLee, S. H., Lindquist, N. C., Wittenberg, N. J., Jordan, L. R., & Oh, S. (2012) · Lab on a Chip · doi:10.1039/c2lc40455a · Cited by 87
Direct Detection of Point Mutations in Nonamplified Human Genomic DNA
D’Agata, R., Breveglieri, G., Zanoli, L. M., Borgatti, M., Spoto, G., & Gambari, R. (2011) · Analytical Chemistry · doi:10.1021/ac2021932 · Cited by 82
Portable point-of-care diagnostic devices
Zhang, W., Guo, S., Carvalho, W. S. P., Jiang, Y., & Serpe, M. J. (2016) · Analytical Methods · doi:10.1039/c6ay02158a · Cited by 81
Shekhar, S., Kumar, R. K., Rai, N., Kumar, V. L., Singh, K. K., Upadhyay, A. D., Tripathi, M., Dwivedi, S. N., Dey, A. B., & Dey, S. (2016) · PLoS ONE · doi:10.1371/journal.pone.0159099 · Cited by 80
Hepatitis B plasmonic biosensor for the analysis of clinical serum samples
Riedel, T., Surman, F., Hageneder, S., Pop‐Georgievski, O., Noehammer, C., Hofner, M., Brynda, E., Rodriguez‐Emmenegger, C., & Dostálek, J. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.05.014 · Cited by 78
Bolduc, O. R., & Masson, J. (2008) · Langmuir · doi:10.1021/la801861q · Cited by 77
Self-citationLee, K.-A., Ahn, J., Lee, S., Sekhon, S. S., Kim, D., Min, J., & Kim, Y. (2015) · Scientific Reports · doi:10.1038/srep10897 · Cited by 74
Label-free SPR detection of gluten peptides in urine for non-invasive celiac disease follow-up
Soler, M., Estévez, M. ‐., Moreno, M. D. L., Cebolla, Á., & Lechuga, L. M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.11.097 · Cited by 73
Surface plasmon resonance immunoassay analysis of pituitary hormones in urine and serum samples
Treviño, J., Calle, A., Rodríguez-Frade, J. M., Mellado, M., & Lechuga, L. M. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.01.015 · Cited by 70
Bolduc, O. R., Clouthier, C. M., Pelletier, J. N., & Masson, J. (2009) · Analytical Chemistry · doi:10.1021/ac900956y · Cited by 70
Self-citationPlasmonic ELISA for the ultrasensitive detection of Treponema pallidum
Nie, X., Huang, R., Dong, C.-X., Tang, L., Gui, R., & Jiang, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.03.007 · Cited by 69
Huang, Y., Chiang, C.-Y., Li, C.-H., Chang, T.-C., Chiang, C.-S., Chau, L., Huang, K.-W., Wu, C.-W., Wang, S., & Lyu, S. (2013) · The Analyst · doi:10.1039/c3an00276d · Cited by 62
Nanostructured substrates for portable and miniature SPR biosensors
Breault-Turcot, J., & Masson, J. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-5963-1 · Cited by 60
Self-citationUse of pooled blood plasmas in the assessment of fouling resistance
Pereira, A. D. L. S., Rodriguez‐Emmenegger, C., Surman, F., Riedel, T., Alles, A. B., & Brynda, E. (2013) · RSC Advances · doi:10.1039/c3ra43093f · Cited by 57
Surface plasmon resonance-based immunoassay for human C-reactive protein
Vashist, S. K., Schneider, E. M., & Luong, J. H. T. (2015) · The Analyst · doi:10.1039/c5an00690b · Cited by 55
Mariani, S., Scarano, S., Spadavecchia, J., & Minunni, M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.071 · Cited by 54
Cancer biomarker discovery using DNA aptamers
Jin, C. Y., Qiu, L., Li, J., Fu, T., Zhang, X., & Tan, W. (2015) · The Analyst · doi:10.1039/c5an01918d · Cited by 54
Adsorption of proteins from infant and adult plasma to biomaterial surfaces
Cornelius, R. M., Archambault, J. G., Berry, L. R., Chan, A. K. C., & Brash, J. L. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10117 · Cited by 54
Bolduc, O. R., Lambert-Lanteigne, P., Colin, D. Y., Zhao, S. S., Proulx, C., Boeglin, D. R., Lubell, W. D., Pelletier, J. N., Féthière, J., Ong, H., et al. (2011) · The Analyst · doi:10.1039/c1an15235a · Cited by 53
Self-citationLee, C., Gamble, L. J., Grainger, D. W., & Castner, D. G. (2006) · Biointerphases · doi:10.1116/1.2219110 · Cited by 51
Real-Time Clinical Monitoring of Biomolecules
Rogers, M. L., & Boutelle, M. G. (2013) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.111808.073648 · Cited by 49
Nechansky, A. (2009) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2009.07.013 · Cited by 47
Novel Biosensor–Based Analytic Device for the Detection of Anti–Double-Stranded DNA Antibodies
Buhl, A., Metzger, J., Heegaard, N. H. H., von Landenberg, P., Fleck, M., & Luppa, P. B. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2006.077339 · Cited by 46
Kai, E., Ikebukuro, K., Hoshina, S., Watanabe, H., & Karube, I. (2000) · FEMS Immunology & Medical Microbiology · doi:10.1111/j.1574-695x.2000.tb01535.x · Cited by 42
Aggregation of biopharmaceuticals in human plasma and human serum
Arvinte, T., Palais, C., Green-Trexler, E., Gregory, S., Mach, H., Narasimhan, C. N., & Shameem, M. (2013) · mAbs · doi:10.4161/mabs.24245 · Cited by 42
Zhao, S. S., Bichelberger, M. A., Colin, D. Y., Robitaille, R., Pelletier, J. N., & Masson, J. (2012) · The Analyst · doi:10.1039/c2an35839e · Cited by 42
Self-citationPEGylated Artificial Antibodies: Plasmonic Biosensors with Improved Selectivity
Luan, J., Liu, K., Tadepalli, S., Jiang, Q., Morrissey, J. J., Kharasch, E. D., & Singamaneni, S. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b07252 · Cited by 42
Live, L. S., Dhawan, A., Gibson, K. F., Poirier-Richard, H.-P., Graham, D., Canva, M., Vo‐Dinh, T., & Masson, J. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6195-0 · Cited by 41
Self-citationLai, T., Hou, Q., Yang, H., Luo, X., & Xi, M. (2010) · Acta Biochimica et Biophysica Sinica · doi:10.1093/abbs/gmq085 · Cited by 41
A review on electronic bio-sensing approaches based on non-antibody recognition elements
Chen, H., Huang, J., Palaniappan, A., Wang, Y., Liedberg, B., Platt, M., & Tok, A. I. Y. (2016) · The Analyst · doi:10.1039/c5an02623g · Cited by 41
Abad, L. W., Neumann, M., Tobias, L. M., Obenauer-Kutner, L. J., Jacobs, S., & Cullen, C. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00314-7 · Cited by 40
Guermazi, S., Regnault, V., Gorgi, Y. L., Ayed, K., Lecompte, T., & Dellagi, K. (2000) · Blood Coagulation & Fibrinolysis · doi:10.1097/00001721-200007000-00012 · Cited by 38
Surface plasmon resonance-based immunoassay for procalcitonin
Vashist, S. K., Schneider, E. M., Barth, E., & Luong, J. H. T. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.08.007 · Cited by 37
Surface plasmon resonance-based immunoassay for human fetuin A
Vashist, S. K., Schneider, E. M., & Luong, J. H. T. (2014) · The Analyst · doi:10.1039/c4an00149d · Cited by 36
Lactose-Functionalized Gold Nanorods for Sensitive and Rapid Serological Diagnosis of Cancer
Zhao, Y., Tong, L., Li, Y., Pan, H., Zhang, W., Guan, M., Li, W., Chen, Y., Li, Q., Li, Z., et al. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b11192 · Cited by 35
Kim, J., Lee, M.-H., Jung, K.-I., Na, H. Y., Cha, H., Ko, E.-M., & Kim, T. J. (2003) · Experimental & Molecular Medicine · doi:10.1038/emm.2003.42 · Cited by 34
Determination of 3-nitrotyrosine in human urine samples by surface plasmon resonance immunoassay
Jin, J., Wang, C., Tao, Y., Tan, Y., Yang, D., Gu, Y., Deng, H., Bai, Y., Lu, H., Wan, Y., et al. (2010) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2010.10.022 · Cited by 33
Joshi, A. A., Peczuh, M. W., Kumar, C. V., & Rusling, J. F. (2014) · The Analyst · doi:10.1039/c4an01544d · Cited by 32
Immunogenicity of therapeutics: a matter of efficacy and safety
Nechansky, A., & Kircheis, R. (2010) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2010.514326 · Cited by 32
Kim, J., Kim, S., Nguyen, T. T., Lee, R., Li, T., Yun, C., Ham, Y., An, S. S. A., & Ju, H. (2016) · Journal of Electronic Materials · doi:10.1007/s11664-015-4292-5 · Cited by 32
Thaler, M., Metzger, J., Schreiegg, A., Denk, B., Gleixner, A., Hauptmann, H., & Luppa, P. B. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2004.034264 · Cited by 31
A Trial to Assess the Amount of Insulin Antibodies in Diabetic Patients by Surface Plasmon Resonance
Kure, M., Katsura, Y., Kosano, H., Noritake, M., Watanabe, T., Iwaki, Y., Nishigori, H., & Matsuoka, T. (2005) · Internal Medicine · doi:10.2169/internalmedicine.44.100 · Cited by 28
An indirect competitive immunoassay for insulin autoantibodies based on surface plasmon resonance
Carlsson, J., Gullstrand, C., Westermark, G. T., Ludvigsson, J., Enander, K., & Liedberg, B. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.07.018 · Cited by 27
Treviño, J., Calle, A., Rodríguez-Frade, J. M., Mellado, M., & Lechuga, L. M. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.06.002 · Cited by 27
Real-time detection of the chemokine CXCL12 in urine samples by surface plasmon resonance
Vega, B., Calle, A., Sánchez, A., Lechuga, L. M., Ortiz, A. M., Armelles, G., Rodríguez-Frade, J. M., & Mellado, M. (2013) · Talanta · doi:10.1016/j.talanta.2013.02.018 · Cited by 27
Naked-eye nanobiosensor for therapeutic drug monitoring of methotrexate
Yockell-Lelièvre, H., Bukar, N., Toulouse, J. L., Pelletier, J. N., & Masson, J. (2015) · The Analyst · doi:10.1039/c5an00996k · Cited by 26
Self-citationGaray, F., Kisiel, G., Fang, A., & Lindner, E. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3736-2 · Cited by 26
Microdialysis SPR: diffusion-gated sensing in blood
Breault-Turcot, J., & Masson, J. (2015) · Chemical Science · doi:10.1039/c5sc00716j · Cited by 24
Self-citationLewis, K. B., Hughes, R. J., Epstein, M. S., Josephson, N. C., Kempton, C. L., Kessler, C. M., Key, N. S., Howard, T. E., Kruse‐Jarres, R., Lusher, J. M., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0061120 · Cited by 24
Clinical Application of Surface Plasmon Resonance-Based Biosensors for Fetal Fibronectin Detection
Chen, C., Chang, C., Yu, C. W., & Lin, C. (2012) · Sensors · doi:10.3390/s120403879 · Cited by 24
Trabucchi, A., Iacono, R. F., Guerra, L. L., Faccinetti, N. I., Krochik, G., Arriazu, M. C., Poskus, E., & Valdez, S. N. (2013) · PLoS ONE · doi:10.1371/journal.pone.0084099 · Cited by 21
Vashist, S. K., Saraswat, M., & Holthšfer, H. (2012) · Procedia Chemistry · doi:10.1016/j.proche.2012.10.145 · Cited by 20
Grzywa, R., Gorodkiewicz, E., Burchacka, E., Lesner, A., Laudański, P., Łukaszewski, Z., & Sieńczyk, M. (2014) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2014.08.029 · Cited by 20
Sahu, V., Gupta, A., Kumar, R. K., Gupta, T., Mohan, A., & Dey, S. (2016) · Clinica Chimica Acta · doi:10.1016/j.cca.2016.07.009 · Cited by 20
Y‐chromosome identification in circulating cell‐free fetal DNA using surface plasmon resonance
Breveglieri, G., Bassi, E., Carlassara, S., Cosenza, L. C., Pellegatti, P., Guerra, G., Finotti, A., Gambari, R., & Borgatti, M. (2016) · Prenatal Diagnosis · doi:10.1002/pd.4788 · Cited by 19
Serodiagnosis of Lyme borreliosis infection using surface plasmon resonance
Nagel, T., Gajovic‐Eichelmann, N., Tobisch, S., Schulte-Spechtel, U. C., & Bier, F. F. (2008) · Clinica Chimica Acta · doi:10.1016/j.cca.2008.04.009 · Cited by 17
Surface plasmon resonance analysis of free IgE in allergic patients receiving omalizumab (Xolair)
Hamilton, R. G., Saini, S. S., & MacGlashan, D. W. (2012) · Journal of Immunological Methods · doi:10.1016/j.jim.2012.05.015 · Cited by 12
ELISA and SPR Studies of Ricin Binding to β-Galactoside Analogs
Mahajan, S. S., & Iyer, S. S. (2012) · Journal of Carbohydrate Chemistry · doi:10.1080/07328303.2012.672606 · Cited by 8
Cited by
Qiu, G., Gai, Z., Tao, Y., Schmitt, J., Kullak-Ublick, G. A., & Wang, J. (2020) · ACS Nano · doi:10.1021/acsnano.0c02439 · Cited by 1,059
Review of Carbon and Graphene Quantum Dots for Sensing
Li, M., Chen, T., Gooding, J. J., & Liu, J. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00514 · Cited by 991
Advances and applications of nanophotonic biosensors
Altug, H., Oh, S.-H., Maier, S. A., & Homola, J. (2022) · Nature Nanotechnology · doi:10.1038/s41565-021-01045-5 · Cited by 882
Optical biosensors: an exhaustive and comprehensive review
Chen, C., & Wang, J. (2020) · The Analyst · doi:10.1039/c9an01998g · Cited by 781
Point-of-care diagnostics for infectious diseases: From methods to devices
Wang, C., Liu, M., Wang, Z., Li, S., Deng, Y., & He, N. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101092 · Cited by 622
Metadata
- Authors
- Masson, J.-F.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-01-06
- Volume
- 2
- Issue
- 1
- Pages
- 16-30
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W2567163077
- Cited by
- 663
- References
- 122
- FWCI
- 22.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.