Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 354

The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.

Wearable Electrochemical Microneedle Sensor for Continuous Monitoring of Levodopa: Toward Parkinson Management

Goud, K. Yugender, Moonla, Chochanon, Mishra, Rupesh K., Yu, Chunmei, Narayan, Roger, Litvan, Irene, Wang, Joseph·2019·ACS Sensors

Abstract

Levodopa is the most effective medication for treating Parkinson's disease (PD). However, because dose optimization is currently based on patients' report of symptoms, which are difficult for patients to describe, the management of PD is challenging. We report on a microneedle sensing platform for continuous minimally invasive orthogonal electrochemical monitoring of levodopa (L-Dopa). The new multimodal microneedle sensing platform relies on parallel simultaneous independent enzymatic-amperometric and nonenzymatic voltammetric detection of L-Dopa using different microneedles on the same sensor array patch. Such real-time orthogonal L-Dopa sensing offers a built-in redundancy and enhances the information content of the microneedle sensor arrays. This is accomplished by rapid detection of L-Dopa using square-wave voltammetry and chronoamperometry at unmodified and tyrosinase-modified carbon-paste microneedle electrodes, respectively. The new wearable microneedle sensor device displays an attractive analytical performance with the enzymatic and nonenzymatic L-Dopa microneedle sensors offering different dimensions of information while displaying high sensitivity (with a low detection limit), high selectivity in the presence of potential interferences, and good stability in artificial interstitial fluid (ISF). The attractive analytical performance and potential wearable applications of the microneedle sensor array have been demonstrated in a skin-mimicking phantom gel as well as upon penetration through mice skin. The design and attractive analytical performance of the new orthogonal wearable microneedle sensor array hold considerable promise for reliable, continuous, minimally invasive monitoring of L-Dopa in the ISF toward optimizing the dosing regimen of the drug and effective management of Parkinson disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acssensors.9b01127

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 44 references

Cited by

See all 354

Metadata

Authors
Goud, K. Y., Moonla, C., Mishra, R. K., Yu, C., Narayan, R., Litvan, I., & Wang, J.
Venue
ACS Sensors
Published
2019-08-12
Volume
4
Issue
8
Pages
2196-2204
ISSN
2379-3694 (ISSN-L)
OpenAlex
W2968188421
Cited by
354
References
44
FWCI
10.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wearable Electrochemical Microneedle Sensor for Continuous Monitoring of Levodopa: Toward Parkinson Management. https://app.cochat.ai/papers/10.1021/acssensors.9b01127
The paper
Goud, K. Y., Moonla, C., Mishra, R. K., Yu, C., Narayan, R., Litvan, I., & Wang, J. (2019). Wearable Electrochemical Microneedle Sensor for Continuous Monitoring of Levodopa: Toward Parkinson Management. ACS Sensors. https://doi.org/10.1021/acssensors.9b01127

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.