The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Aptamer Modules as Sensors and Detectors
Abstract
Aptamers comprise a range of molecular recognition scaffolds that can be engineered to bind to a legion of different proteins and other targets with excellent specificity and affinity. Because these non-natural oligonucleotides are accessible entirely synthetically, aptamers can be equipped with all sorts of reporter groups and can be coupled to many different carriers, surfaces, nanoparticles, or other biomolecules. They can be used in a highly modular fashion and often recognize their targets by a mechanism in which the aptamer undergoes considerable structural rearrangement, which can be exploited for transducing a binding event into a signal. As a consequence, aptamers have been adapted to a huge variety of "read-out configurations" and are increasingly used as capture agents in many different bioanalytical methods. But despite considerable success with these applications, many remaining challenges must still be overcome for the more widespread incorporation of aptasensors in clinical and environmental biosensing and diagnostics to take place. Some particularly noteworthy progress on this front is currently being made with aptasensor configurations that can be used for the multiplexed sensing of many analytes in parallel. In this Account, we describe some of the concepts involved in transducing the binding of a ligand into a signal through various physico-chemical interactions. Research in this area usually involves the combination of the molecular biology of proteins and nucleic acids with biotechnology, synthetic chemistry, physical chemistry, and surface physics. We begin with a brief introduction of the properties and characteristics that qualify aptamers as capture agents for many different analytes and their suitability as highly versatile biosensor components. We then address approaches that apply to surface acoustic wave configurations, drawing largely from our own contributions to aptasensor development, before moving on to describe previous and recent progress in multiplexed aptasensors. Obtaining proteome-wide profiles in cells, organs, organisms, or full populations requires the ability to accurately measure many different analytes in small sample volumes over a broad dynamic range. Multiplexed sensing is an invaluable tool in this endeavor. We discuss what we consider the biggest obstacles to the broader clinical use of aptasensor-based diagnostics and our perspective on how they can be surmounted. Finally,we explore the tremendous potential of aptamer-based sensors that can specifically discriminate between diseased and healthy cells. Progress in these areas will greatly expand the range of aptasensor applications, leading to enhanced diagnosis of diseases in clinical practice and, ultimately, improved patient care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Selection of single-stranded DNA molecules that bind and inhibit human thrombin
Bock, L. C., Griffin, L. C., Latham, J. A., Vermaas, E. H., & Toole, J. J. (1992) · Nature · doi:10.1038/355564a0 · Cited by 2,469
Functional Nucleic Acid Sensors
Liu, J., Cao, Z., & Lu, Y. (2009) · Chemical Reviews · doi:10.1021/cr030183i · Cited by 2,187
Aptamer-Based Multiplexed Proteomic Technology for Biomarker Discovery
Gold, L., Ayers, D., Bertino, J., Bock, C., Bock, A., Brody, E. N., Carter, J., Dalby, A. B., Eaton, B. E., Fitzwater, T., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015004 · Cited by 1,754
Functional Aptamers and Aptazymes in Biotechnology, Diagnostics, and Therapy
Famulok, M., Hartig, J. S., & Mayer, G. (2007) · Chemical Reviews · doi:10.1021/cr0306743 · Cited by 887
Self-citationOligonucleotide inhibitors of human thrombin that bind distinct epitopes
Tasset, D. M., Kubik, M. F., & Steiner, W. (1997) · Journal of Molecular Biology · doi:10.1006/jmbi.1997.1275 · Cited by 837
Electronic Aptamer‐Based Sensors
Willner, I., & Zayats, M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200604524 · Cited by 818
Label‐Free Electronic Detection of Thrombin in Blood Serum by Using an Aptamer‐Based Sensor
Xiao, Y., Lubin, A. A., Heeger, A. J., & Plaxco, K. W. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200500989 · Cited by 812
Surface acoustic wave biosensors: a review
Länge, K., Rapp, B. E., & Rapp, M. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1911-5 · Cited by 806
Applications of Aptamers as Sensors
Cho, E. J., Lee, J.-W., & Ellington, A. D. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112851 · Cited by 788
The Chemical Biology of Aptamers
Mayer, G. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200804643 · Cited by 592
Self-citation
Cited by
The Optoelectronic Nose: Colorimetric and Fluorometric Sensor Arrays
Li, Z., Askim, J. R., & Suslick, K. S. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00226 · Cited by 1,191
Wang, F., Lu, C.-H., & Willner, I. (2014) · Chemical Reviews · doi:10.1021/cr400354z · Cited by 649
Song, Y., Zhu, Z., An, Y., Zhang, W., Zhang, H., Liu, D., Yu, C., Duan, W., & Yang, C. J. (2013) · Analytical Chemistry · doi:10.1021/ac400366b · Cited by 525
DNA Switches: From Principles to Applications
Wang, F., Liu, X., & Willner, I. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201404652 · Cited by 467
Stimuli‐Responsive Biomolecule‐Based Hydrogels and Their Applications
Vázquez‐González, M., & Willner, I. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201907670 · Cited by 444
Metadata
- Authors
- Famulok, M., & Mayer, G.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-08-05
- Volume
- 44
- Issue
- 12
- Pages
- 1349-1358
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W1980657872
- Cited by
- 300
- References
- 48
- FWCI
- 11.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Aptamer Modules as Sensors and Detectors. https://app.cochat.ai/papers/10.1021/ar2000293
- The paper
- Famulok, M., & Mayer, G. (2011). Aptamer Modules as Sensors and Detectors. Accounts of Chemical Research. https://doi.org/10.1021/ar2000293
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.