Microfluidics-Based in Vivo Mimetic Systems for the Study of Cellular Biology
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
The human body is a complex network of molecules, organelles, cells, tissues, and organs: an uncountable number of interactions and transformations interconnect all the system's components. In addition to these biochemical components, biophysical components, such as pressure, flow, and morphology, and the location of all of these interactions play an important role in the human body. Technical difficulties have frequently limited researchers from observing cellular biology as it occurs within the human body, but some state-of-the-art analytical techniques have revealed distinct cellular behaviors that occur only in the context of the interactions. These types of findings have inspired bioanalytical chemists to provide new tools to better understand these cellular behaviors and interactions. What blocks us from understanding critical biological interactions in the human body? Conventional approaches are often too naïve to provide realistic data and in vivo whole animal studies give complex results that may or may not be relevant for humans. Microfluidics offers an opportunity to bridge these two extremes: while these studies will not model the complexity of the in vivo human system, they can control the complexity so researchers can examine critical factors of interest carefully and quantitatively. In addition, the use of human cells, such as cells isolated from donated blood, captures human-relevant data and limits the use of animals in research. In addition, researchers can adapt these systems easily and cost-effectively to a variety of high-end signal transduction mechanisms, facilitating high-throughput studies that are also spatially, temporally, or chemically resolved. These strengths should allow microfluidic platforms to reveal critical parameters in the human body and provide insights that will help with the translation of pharmacological advances to clinical trials. In this Account, we describe selected microfluidic innovations within the last 5 years that focus on modeling both biophysical and biochemical interactions in cellular communication, such as flow and cell-cell networks. We also describe more advanced systems that mimic higher level biological networks, such as organ on-a-chip and animal on-a-chip models. Since the first papers in the early 1990s, interest in the bioanalytical use of microfluidics has grown significantly. Advances in micro-/nanofabrication technology have allowed researchers to produce miniaturized, biocompatible assay platforms suitable for microfluidic studies in biochemistry and chemical biology. Well-designed microfluidic platforms can achieve quick, in vitro analyses on pico- and femtoliter volume samples that are temporally, spatially, and chemically resolved. In addition, controlled cell culture techniques using a microfluidic platform have produced biomimetic systems that allow researchers to replicate and monitor physiological interactions. Pioneering work has successfully created cell-fluid, cell-cell, cell-tissue, tissue-tissue, even organ-like level interfaces. Researchers have monitored cellular behaviors in these biomimetic microfluidic environments, producing validated model systems to understand human pathophysiology and to support the development of new therapeutics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Three-dimensional microfluidic model for tumor cell intravasation and endothelial barrier function
Zervantonakis, I. K., Hughes-Alford, S. K., Charest, J. L., Condeelis, J. S., Gertler, F. B., & Kamm, R. D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210182109 · Cited by 872
Biomimetic tissues on a chip for drug discovery
Ghaemmaghami, A. M., Hancock, M. J., Harrington, H., Kaji, H., & Khademhosseini, A. (2012) · Drug Discovery Today · doi:10.1016/j.drudis.2011.10.029 · Cited by 359
Microfluidic system for formation of PC-3 prostate cancer co-culture spheroids
Hsiao, A. Y., Torisawa, Y.-S., Tung, Y.-C., Sud, S., Taichman, R. S., Pienta, K. J., & Takayama, S. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.02.047 · Cited by 323
Lee, S.-A., No, D. Y., Kang, E., Ju, J., Kim, D.-S., & Lee, S.-H. (2013) · Lab on a Chip · doi:10.1039/c3lc50197c · Cited by 297
Self-citationZeck, G., & Fromherz, P. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.181348698 · Cited by 290
Patra, B., Chen, Y.-H., Peng, C.-C., Lin, S.-C., Lee, C.-H., & Tung, Y.-C. (2013) · Biomicrofluidics · doi:10.1063/1.4824480 · Cited by 109
Cited by
Organ-Tumor-on-a-Chip for Chemosensitivity Assay: A Critical Review
Kashaninejad, N., Nikmaneshi, M., Moghadas, H., Kiyoumarsi Oskouei, A., Rismanian, M., Barisam, M., Saidi, M., & Firoozabadi, B. (2016) · Micromachines · doi:10.3390/mi7080130 · Cited by 79
Advances of Stem Cell-Laden Hydrogels With Biomimetic Microenvironment for Osteochondral Repair
Xu, B., Ye, J., Yuan, F.-Z., Zhang, J.-Y., Chen, Y.-R., Fan, B.-S., Jiang, D., Jiang, W.-B., Wang, X., & Yu, J.-K. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00247 · Cited by 48
Microfluidic co-culture devices to assess penetration of nanoparticles into cancer cell mass
Jarvis, M., Arnold, M., Ott, J., Pant, K., Prabhakarpandian, B., & Mitragotri, S. (2017) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10079 · Cited by 32
Yildiz-Ozturk, E., Gulce-Iz, S., Anil, M., & Yesil-Celiktas, O. (2017) · Cytotechnology · doi:10.1007/s10616-016-0062-3 · Cited by 32
Metadata
- Authors
- Kim, D., Wu, X., Young, A. T., & Haynes, C. L.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-02-20
- Volume
- 47
- Issue
- 4
- Pages
- 1165-1173
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2084726488
- Cited by
- 68
- References
- 9
- FWCI
- 4.14
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microfluidics-Based in Vivo Mimetic Systems for the Study of Cellular Biology. https://app.cochat.ai/papers/10.1021/ar4002608
- The paper
- Kim, D., Wu, X., Young, A. T., & Haynes, C. L. (2014). Microfluidics-Based in Vivo Mimetic Systems for the Study of Cellular Biology. Accounts of Chemical Research. https://doi.org/10.1021/ar4002608
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.