Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 737

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Target-Responsive Structural Switching for Nucleic Acid-Based Sensors

Li, Di, Song, Shiping, Fan, Chunhai·2010·Accounts of Chemical Research

Abstract

Interest in the development of sensitive, selective, rapid, and cost-effective biosensors for biomedical analysis, environmental monitoring, and the detection of bioterrorism agents is rapidly increasing. A classic biosensor directly transduces ligand-target binding events into a measurable physical readout. More recently, researchers have proposed novel biosensing strategies that couple ligand-induced structural switching of biomolecules with advanced optical and electronic transducers. This approach has proven to be a highly general platform for the development of new biosensors. In this Account, we describe a series of electrochemical and optical nucleic acid sensors that use target-responsive DNA structures. By employing surface-confined DNA structures with appropriate redox labels, we can monitor target-induced structural switching of DNA or aptamer-specific small molecule probes by measuring electrochemical currents that are directly associated with the distance between the redox label and the electrode surface. We have also demonstrated significant improvements in sensing performance through optimization of the DNA self-assembly process at electrode surfaces or the introduction of nanomaterial-based signal amplification. Alternatively, gold nanoparticles interact differently with folded and unfolded DNA structures, which provides a visual method for detecting target-induced structural switching based on the plasmonic change of gold nanoparticles. This novel method using gold nanoparticles has proven particularly suitable for the detection of a range of small-molecule targets (e.g., cocaine) and environmentally toxic metal ions (e.g., Hg(2+)). Rational sequence design of DNA aptamers improves the sensitivity and increases the reaction kinetics. Recently, we have also designed microfluidic devices that allow rapid and portable mercury detection with the naked eye. This Account focuses on the use of bulk and nanoscale gold and DNA/aptamer molecules. We expect that researchers will further expand the analyte spectrum and improve the sensitivity and selectivity of nucleic acid sensors using functional biomolecules, such as DNAzymes, peptide aptamers and engineered proteins, and nanomaterials of different sizes, dimensions and compositions, such as carbon nanotubes, graphene, silicon nanowires, and metal nanoparticles or nanorods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ar900245u

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 737

Metadata

Authors
Li, D., Song, S., & Fan, C.
Venue
Accounts of Chemical Research
Published
2010-03-11
Volume
43
Issue
5
Pages
631-641
ISSN
  • 0001-4842 (ISSN-L)
  • 1520-4898
OpenAlex
W2074711360
Cited by
737
References
3
FWCI
31.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Target-Responsive Structural Switching for Nucleic Acid-Based Sensors. https://app.cochat.ai/papers/10.1021/ar900245u
The paper
Li, D., Song, S., & Fan, C. (2010). Target-Responsive Structural Switching for Nucleic Acid-Based Sensors. Accounts of Chemical Research. https://doi.org/10.1021/ar900245u

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.