The DOI matches its Crossref record.
Green Fluorescent Protein Variants as Ratiometric Dual Emission pH Sensors. 1. Structural Characterization and Preliminary Application
Abstract
Novel dual emission, pH-sensitive variants of the green fluorescent protein (GFP) have been constructed and are suitable for ratiometric emission measurements in vivo. This new class of GFPs, termed deGPFs, results from substitution of wild-type residue 65 with threonine and residues 148 and/or 203 with cysteine. deGFPs display pK(a) values ranging from 6.8 to 8.0 and emission that switches from a green form (lambda(max) approximately 515 nm) to a blue form (lambda(max) approximately 460 nm) with acidifying pH. In this report we analyze in most detail the deGFP1 variant (S65T/H148G/T203C, pK(a) approximately 8.0) and the deGFP4 variant (S65T/C48S/H148C/T203C, pK(a) approximately 7.3). In the following paper [McAnaney, T. B., Park, E. S., Hanson, G. T., Remington, S. J., and Boxer, S. G. (2002) Biochemistry 41, 15489-15494], data obtained by ultrafast fluorescence upconversion spectroscopy can be described by a kinetic model that includes an excited-state proton-transfer pathway at high pH but not at low pH. Crystal structure analyses of deGFP1 at high-pH and low-pH conformations were performed to elucidate the basis for the dual emission characteristics. At low pH the structure does not contain a hydrogen bond network that would support rapid transfer of a proton from the excited state of the neutral chromophore to a suitable acceptor; hence blue emission is observed. At high pH, backbone rearrangements induced by changes in the associated hydrogen bond network permit excited-state proton transfer from the excited state of the neutral chromophore to the bulk solvent via Ser147 and bound water molecules, resulting in green emission from the anionic chromophore. Comparative analysis suggests that the basis for dual emission is elimination of the wild-type proton-transfer network by the S65T substitution, a general reduction in hydrogen-bonding opportunities, and a concomitant increase in the hydrophobic nature of the chromophore environment resulting from the cysteine substitutions. We evaluated the suitability of the deGFP4 variant for intracellular pH measurements in mammalian cells by transient expression in PS120 fibroblasts. The responses of deGFP4 and a commercially available pH-sensitive dye, SNARF-1, to changes in pH were compared in the same cells. Results show that the dynamic range of the emission ratio change is comparable between the two pH sensors over the range examined. Two-photon excitation was found to elicit a better deGFP4 fluorescent signal above cellular autofluorescence when compared to conventional confocal microscopy. Given their favorable optical characteristics, suitable pK(a)'s for the physiological pH range, and suitability for ratiometric measurements, dual emission GFPs should make excellent probes for studying pH in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
Fluorescent Proteins and Their Applications in Imaging Living Cells and Tissues
Chudakov, D. M., Matz, M. V., Lukyanov, S., & Lukyanov, K. A. (2010) · Physiological Reviews · doi:10.1152/physrev.00038.2009 · Cited by 1,375
Hanson, G. T., Aggeler, R., Oglesbee, D., Cannon, M., Capaldi, R. A., Tsien, R. Y., & Remington, S. J. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m312846200 · Cited by 988
Self-citationOptical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Fluorescent proteins as a toolkit for in vivo imaging
Chudakov, D. M., Lukyanov, S., & Lukyanov, K. A. (2005) · Trends in Biotechnology · doi:10.1016/j.tibtech.2005.10.005 · Cited by 498
The pH of the Secretory Pathway: Measurement, Determinants, and Regulation
Paroutis, P., Touret, N., & Grinstein, S. (2004) · Physiology · doi:10.1152/physiol.00005.2004 · Cited by 450
Imaging Intracellular pH in Live Cells with a Genetically Encoded Red Fluorescent Protein Sensor
Tantama, M., Hung, Y. P., & Yellen, G. (2011) · Journal of the American Chemical Society · doi:10.1021/ja202902d · Cited by 408
Organelle pH in the Arabidopsis Endomembrane System
Shen, J., Zeng, Y., Zhuang, X., Sun, L., Yao, X., Pimpl, P., & Jiang, L. (2013) · Molecular Plant · doi:10.1093/mp/sst079 · Cited by 359
Two-Photon Microscopy of Cells and Tissue
Rubart, M. (2004) · Circulation Research · doi:10.1161/01.res.0000150593.30324.42 · Cited by 339
Fluorescent proteins for live-cell imaging with super-resolution
Nienhaus, K., & Ulrich Nienhaus, G. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60171d · Cited by 337
Fluorescent proteins: maturation, photochemistry and photophysics
Remington, S. J. (2006) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2006.10.001 · Cited by 326
Self-citationExcited state reactions in fluorescent proteins
Meech, S. R. (2009) · Chemical Society Reviews · doi:10.1039/b820168b · Cited by 325
Green fluorescent protein: A perspective
Remington, S. J. (2011) · Protein Science · doi:10.1002/pro.684 · Cited by 260
Self-citationMitochondrial pH Monitored by a New Engineered Green Fluorescent Protein Mutant
Abad, M. F. C., Di Benedetto, G., Magalhães, P. J., Filippin, L., & Pozzan, T. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m306766200 · Cited by 258
Metadata
- Authors
- Hanson, G. T., McAnaney, T. B., Park, E. S., Rendell, M. E. P., Yarbrough, D. K., Chu, S., Xi, L., Boxer, S. G., Montrose, M. H., & Remington, S. J.
- Venue
- Biochemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-12-01
- Volume
- 41
- Issue
- 52
- Pages
- 15477-15488
- ISSN
- 0006-2960 (ISSN-L)
- 1520-4995
- OpenAlex
- W2134667534
- Cited by
- 238
- References
- 0
- FWCI
- 5.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.