The DOI matches its Crossref record.
Recombinant Protein-co-PEG Networks as Cell-Adhesive and Proteolytically Degradable Hydrogel Matrixes. Part I: Development and Physicochemical Characteristics
Abstract
Toward the development of synthetic bioactive materials to support tissue repair, we present here the design, production, and characterization of genetically engineered protein polymers carrying specific key features of the natural extracellular matrix, as well as cross-linking with functionalized poly(ethylene glycol) (PEG) to form hybrid hydrogel networks. The repeating units of target recombinant protein polymers contain a cell-binding site for ligation of cell-surface integrin receptors and substrates for plasmin and matrix metalloproteinases (MMPs), proteases implicated in wound healing and tissue regeneration. Hydrogels were formed under physiological conditions via Michael-type conjugate addition of vinyl sulfone groups of end-functionalized PEG with thiols of cysteine residues, representing designed chemical cross-linking sites within recombinant proteins. Cross-linking kinetics was shown to increase with the pH of precursor solutions. The elastic moduli (G') and swelling ratios (Q(m)) of the resulting hydrogels could be varied as a function of the stoichiometry of the reacting groups and precursor concentration. Optima of G' and Q(m), maximum and minimum, respectively, were obtained at stoichiometry ratios r slightly in excess of 1 (r = cysteine/vinyl sulfone). The pool of technologies utilized here represents a promising approach for the development of artificial matrixes tailored for specific medical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Thiol-Michael Addition Click Reaction: A Powerful and Widely Used Tool in Materials Chemistry
Nair, D. P., Podgórski, M., Chatani, S., Gong, T., Xi, W., Fenoli, C. R., & Bowman, C. N. (2014) · Chemistry of Materials · doi:10.1021/cm402180t · Cited by 1,596
Design properties of hydrogel tissue-engineering scaffolds
Zhu, J., & Marchant, R. E. (2011) · Expert Review of Medical Devices · doi:10.1586/erd.11.27 · Cited by 1,430
PEG Hydrogels for the Controlled Release of Biomolecules in Regenerative Medicine
Lin, C.-C., & Anseth, K. S. (2009) · Pharmaceutical Research · doi:10.1007/s11095-008-9801-2 · Cited by 1,063
Protein Immobilization Strategies for Protein Biochips
Rusmini, F., Zhong, Z., & Feijen, J. (2007) · Biomacromolecules · doi:10.1021/bm061197b · Cited by 869
Polymer-Based Hydrogels Applied in Drug Delivery: An Overview
Thang, N. H., Chien, T. B., & Cuong, D. X. (2023) · Gels · doi:10.3390/gels9070523 · Cited by 812
Click hydrogels, microgels and nanogels: Emerging platforms for drug delivery and tissue engineering
Jiang, Y., Chen, J., Deng, C., Suuronen, E. J., & Zhong, Z. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.03.001 · Cited by 762
Polymer Scaffolds for Biomaterials Applications
Shoichet, M. S. (2010) · Macromolecules · doi:10.1021/ma901530r · Cited by 468
Controlled Growth Factor Delivery for Tissue Engineering
Tayalia, P., & Mooney, D. J. (2009) · Advanced Materials · doi:10.1002/adma.200900241 · Cited by 430
Matrices and scaffolds for protein delivery in tissue engineering
Tessmar, J. K., & Göpferich, A. M. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.03.020 · Cited by 346
Peptide-based biopolymers in biomedicine and biotechnology
Chow, D., Nunalee, M. L., Lim, D. W., Simnick, A. J., & Chilkoti, A. (2008) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2008.04.004 · Cited by 327
Tissue Engineering of Articular Cartilage with Biomimetic Zones
Klein, T. J., Malda, J., Sah, R. L., & Hutmacher, D. W. (2009) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2008.0563 · Cited by 315
Biomolecular Hydrogels Formed and Degraded via Site-Specific Enzymatic Reactions
Ehrbar, M., Rizzi, S. C., Schoenmakers, R. G., San Miguel, B., Hubbell, J. A., Weber, F. E., & Lutolf, M. P. (2007) · Biomacromolecules · doi:10.1021/bm070228f · Cited by 299
Self-citationSalinas, C. N., & Anseth, K. S. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.01.035 · Cited by 298
Tuning the erosion rate of artificial protein hydrogels through control of network topology
Shen, W., Zhang, K., Kornfield, J. A., & Tirrell, D. A. (2006) · Nature Materials · doi:10.1038/nmat1573 · Cited by 294
Matrix degradability controls multicellularity of 3D cell migration
Trappmann, B., Baker, B. M., Polacheck, W. J., Choi, C. K., Burdick, J. A., & Chen, C. S. (2017) · Nature Communications · doi:10.1038/s41467-017-00418-6 · Cited by 264
(1981) · PubMed · Cited by 235
Metadata
- Authors
- Rizzi, S. C., & Hubbell, J. A.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-03-04
- Volume
- 6
- Issue
- 3
- Pages
- 1226-1238
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2120346745
- Cited by
- 197
- References
- 0
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.