The DOI matches its Crossref record.
Why is Chitosan Mucoadhesive?
Abstract
Chitosan is a biocompatible and biodegradable amino polysaccharide, which is soluble in aqueous solutions at pH < 6.5. It has been widely used for developing drug delivery systems because of its excellent mucoadhesive properties. Although many studies report on chitosan being mucoadhesive, the nature of interactions between chitosan and mucin remains poorly defined. Here, we have examined the role of primary amino groups and the role of electrostatic attraction, hydrogen bonding, and hydrophobic effects on aggregation of gastric mucin in the presence of chitosan. Reducing the number of amino groups through their half acetylation results in expansion of chitosan's pH-solubility window up to pH 7.4 but also reduces its capacity to aggregate mucin. We demonstrated that electrostatic attraction forces between chitosan and gastric mucin can be suppressed in the presence of 0.2 mol/L sodium chloride; however, this does not prevent the aggregation of mucin particles in the presence of this biopolymer. The presence of 8 mol/L urea or 10% v/v ethanol in solutions also affects mucin aggregation in the presence of chitosan, demonstrating the role of hydrogen bonding and hydrophobic effects, respectively, in mucoadhesion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Exploring the factors affecting the solubility of chitosan in water
Sogias, I. A., Khutoryanskiy, V. V., & Williams, A. C. (2010) · Macromolecular Chemistry and Physics · doi:10.1002/macp.200900385 · Cited by 293
Self-citationChitosan based bioadhesives for biomedical applications: A review
Hamedi, H., Moradi, S., Hudson, S. M., Tonelli, A. E., & King, M. W. (2022) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2022.119100 · Cited by 281
Polymeric micelles in mucosal drug delivery: challenges towards clinical translation
Sosnik, A., & Menaker Raskin, M. (2015) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.01.003 · Cited by 154
Thermosensitive hexanoyl glycol chitosan-based ocular delivery system for glaucoma therapy
Cho, I. S., Park, C. G., Huh, B. K., Cho, M. O., Khatun, Z., Li, Z., Kang, S.-W., Choy, Y. B., & Huh, K. M. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.05.011 · Cited by 106
Chen, X., Zhao, X., & Wang, G. (2020) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2020.116311 · Cited by 72
Mendes, A. C., Sevilla Moreno, J., Hanif, M., E.L. Douglas, T., Chen, M., & Chronakis, I. S. (2018) · International Journal of Molecular Sciences · doi:10.3390/ijms19082266 · Cited by 55
Samprasit, W., Opanasopit, P., & Chamsai, B. (2021) · Pharmaceutical Development and Technology · doi:10.1080/10837450.2021.1873370 · Cited by 50
Ch, S., Padaga, S. G., Ghosh, B., Roy, S., & Biswas, S. (2023) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2023.120822 · Cited by 40
RetractedDi Cola, E., Cantu’, L., Brocca, P., Rondelli, V., Fadda, G. C., Canelli, E., Martelli, P., Clementino, A., Sonvico, F., Bettini, R., et al. (2019) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2019.110439 · Cited by 36
Metadata
- Authors
- Sogias, I. A., Williams, A. C., & Khutoryanskiy, V. V.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-06-10
- Volume
- 9
- Issue
- 7
- Pages
- 1837-1842
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W1998624966
- Cited by
- 779
- References
- 0
- FWCI
- 8.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.