CoChat

Indoor Particulate Matter of Outdoor Origin: Importance of Size-Dependent Removal Mechanisms

Riley, William J., McKone, Thomas E., Lai, Alvin C. K., Nazaroff, William W. · 2002 · Environmental Science & Technology

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Abstract

Adverse human health effects have been observed to correlate with levels of outdoor particulate matter (PM), even though most human exposure to PM of outdoor origin occurs indoors. In this study, we apply a model and empirical data to explore the indoor PM levels of outdoor origin for two major building types: offices and residences. Typical ventilation rates for each building type are obtained from the literature. Published data are combined with theoretical analyses to develop representative particle penetration coefficients, deposition loss rates, and ventilation-system filter efficiencies for a broad particle size range (i.e., 0.001-10 microm). We apply archetypal outdoor number, surface area, and mass PM size distributions for both urban and rural airsheds. We also use data on mass-weighted size distributions for specific chemical constituents of PM: sulfate and elemental carbon. Predictions of the size-resolved indoor proportion of outdoor particles (IPOP) for various conditions and ambient particle distributions are then computed. The IPOP depends strongly on the ambient particle size distribution, building type and operational parameters, and PM metric. We conclude that an accurate determination of exposure to particles of ambient origin requires explicit consideration of how removal processes in buildings vary with particle size.

Overview

Integrity signals

Registry

Crossref · 10.1021/es010723y

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 15

  1. Klemm R. J., 2000, J. Air Waste Manage. Assoc., 50, 1222
  2. Pope C. A., 1999, Am. Heart J., 138, 899
  3. Klepeis N. E., 2001, J. Exposure Anal. Environ. Epidemiol., 11, 252
  4. Lioy P. J., 1988, Arch. Environ. Health, 43, 312
  5. Yocum J. E., 1982, JAPCA, 32, 520
  6. Ozkaynak H., 1996, J. Exposure Anal. Environ. Epidemiol., 6, 78
  7. Long C. M., 2001, Environ. Sci. Technol., 35, 2099
  8. Abt E., 2000, Environ. Sci. Technol., 34, 3587
  9. Persily A., 1989, IAQ '89 Conference
  10. ASHRAE., 1993, ASHRAE Handbook: Fundamentals
  11. Xu M. D., 1994, Aerosol Sci. Technol., 20, 206
  12. Fogh C. L., 1997, Atmos. Environ., 31, 2203
  13. Liu D., 2001, Atmos. Environ., 35, 4462
  14. Whitby K. T., 1978, Atmos. Environ., 12, 159
  15. Ott W., 2000, J. Air Waste Manage. Assoc., 50, 1406

Cited by

See all 417

Metadata

Authors
Riley, W. J., McKone, T. E., Lai, A. C. K., & Nazaroff, W. W.
Affiliations
Lawrence Berkeley National Laboratory (US)
Corresponding author
Riley, William J.
Venue
Environmental Science & Technology
Published
2001-12-13
Volume
36
Issue
2
Pages
200-207
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W1973118576
Cited by
417
References
33
Citations by year
2026: 8 · 2025: 11 · 2024: 11 · 2023: 10 · 2022: 23 · 2021: 22 · 2020: 29 · 2019: 22 · 2018: 25 · 2017: 21 · 2016: 19 · 2015: 32 · 2014: 27 · 2013: 18 · 2012: 26
FWCI
6.57
Type
journal article
Language
en
Open access
closed
Locations
  • Environmental Science & Technology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
  • Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric chemistry and aerosols
Keywords
indoor particulate matter, particle size dependence, particle removal mechanism, particle deposition, ventilation filters, office buildings, residential buildings, ventilation rate, particle size distribution, sulfate, elemental carbon, indoor air quality, human exposure
MeSH terms
Air Movements, Air Pollutants, Environmental Exposure, Forecasting, Humans, Models, Theoretical, Particle Size, Public Health, Air Pollution, Indoor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.