Indoor Particulate Matter of Outdoor Origin: Importance of Size-Dependent Removal Mechanisms
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Adverse human health effects have been observed to correlate with levels of outdoor particulate matter (PM), even though most human exposure to PM of outdoor origin occurs indoors. In this study, we apply a model and empirical data to explore the indoor PM levels of outdoor origin for two major building types: offices and residences. Typical ventilation rates for each building type are obtained from the literature. Published data are combined with theoretical analyses to develop representative particle penetration coefficients, deposition loss rates, and ventilation-system filter efficiencies for a broad particle size range (i.e., 0.001-10 microm). We apply archetypal outdoor number, surface area, and mass PM size distributions for both urban and rural airsheds. We also use data on mass-weighted size distributions for specific chemical constituents of PM: sulfate and elemental carbon. Predictions of the size-resolved indoor proportion of outdoor particles (IPOP) for various conditions and ambient particle distributions are then computed. The IPOP depends strongly on the ambient particle size distribution, building type and operational parameters, and PM metric. We conclude that an accurate determination of exposure to particles of ambient origin requires explicit consideration of how removal processes in buildings vary with particle size.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Riley et al. [10] suggested that the penetration of particles through building cracks would significantly affect indoor air quality, especially for buildings where air exchange through openings or cracks is dominated by pressure differences arising from natural forces.”
From Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China (2017) · cites this paper as [10]
Citations
Cites
Atmospheric chemistry and physics: from air pollution to climate change
(1998) · Choice Reviews Online · doi:10.5860/choice.35-5721 · Cited by 4,944
Aerosol Technology Properties, Behavior, and Measurement of Airborne Particles
LAUCKS, M. L. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00571-6 · Cited by 3,367
Chemistry of the Upper and Lower Atmosphere: Theory, Experiments, and Applications
Finlayson‐Pitts, B. J., & PITTS, J. N. J. (1999) · Cited by 3,055
Uncertainty: A Guide to Dealing with Uncertainty in Quantitative Risk and Policy Analysis
Morgan, M. G., & Henrion, M. (1990) · Cambridge University Press eBooks · doi:10.1017/cbo9780511840609 · Cited by 1,711
Is Daily Mortality Associated Specifically with Fine Particles?
Schwartz, J., Dockery, D. W., & Neas, L. M. (1996) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1996.10467528 · Cited by 1,561
Deposition, resuspension, and penetration of particles within a residence
Thatcher, T. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00016-r · Cited by 859
Air pollution and incidence of cardiac arrhythmia
Peters, A., Liu, E., Verrier, R. L., Schwartz, J., Gold, D. R., Mittleman, M., Baliff, J., Oh, J. A., Allen, G., Monahan, K., et al. (2000) · Epidemiology · doi:10.1097/00001648-200001000-00005 · Cited by 651
Activity patterns of Californians: Use of and proximity to indoor pollutant sources
Jenkins, P. L., Phillips, T. J., Mulberg, E. J., & Hui, S. P. (1992) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(92)90402-7 · Cited by 415
Radon and its decay products in indoor air
Benarie, M. (1989) · Science of The Total Environment · doi:10.1016/0048-9697(89)90061-2 · Cited by 402
Jones, N. C., Thornton, C. A., Mark, D., & Harrison, R. M. (2000) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00489-6 · Cited by 374
Research works printed but not linked: 15
- Klemm R. J., 2000, J. Air Waste Manage. Assoc., 50, 1222
- Pope C. A., 1999, Am. Heart J., 138, 899
- Klepeis N. E., 2001, J. Exposure Anal. Environ. Epidemiol., 11, 252
- Lioy P. J., 1988, Arch. Environ. Health, 43, 312
- Yocum J. E., 1982, JAPCA, 32, 520
- Ozkaynak H., 1996, J. Exposure Anal. Environ. Epidemiol., 6, 78
- Long C. M., 2001, Environ. Sci. Technol., 35, 2099
- Abt E., 2000, Environ. Sci. Technol., 34, 3587
- Persily A., 1989, IAQ '89 Conference
- ASHRAE., 1993, ASHRAE Handbook: Fundamentals
- Xu M. D., 1994, Aerosol Sci. Technol., 20, 206
- Fogh C. L., 1997, Atmos. Environ., 31, 2203
- Liu D., 2001, Atmos. Environ., 35, 4462
- Whitby K. T., 1978, Atmos. Environ., 12, 159
- Ott W., 2000, J. Air Waste Manage. Assoc., 50, 1406
Cited by
Chen, C., & Zhao, B. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.09.048 · Cited by 972
Nazaroff, W. W. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00286.x · Cited by 639
Self-citationEffects of room furnishings and air speed on particle deposition rates indoors
Thatcher, T. L., Lai, A. C. K., Moreno-Jackson, R., Sextro, R. G., & Nazaroff, W. W. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00157-7 · Cited by 416
Self-citationSize‐resolved emission rates of airborne bacteria and fungi in an occupied classroom
Qian, J., Hospodsky, D., Yamamoto, N., Nazaroff, W. W., & Peccia, J. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00769.x · Cited by 395
Self-citationMorawska, L., Ayoko, G. A., Bae, G. N., Buonanno, G., Chao, C. Y. H., Clifford, S., Fu, S. C., Hänninen, O., He, C., Isaxon, C., et al. (2017) · Environment International · doi:10.1016/j.envint.2017.07.025 · Cited by 374
Aerobiology and Its Role in the Transmission of Infectious Diseases
Fernstrom, A., & Goldblatt, M. (2013) · Journal of Pathogens · doi:10.1155/2013/493960 · Cited by 363
Nazaroff, W. W. (2016) · Indoor Air · doi:10.1111/ina.12174 · Cited by 304
Self-citationParticle size characterization and emission rates during indoor activities in a house
Hussein, T., Glytsos, T., Ondráček, J., Dohányosová, P., Ždímal, V., Hämeri, K., Lazaridis, M., Smolík, J., & Kulmala, M. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.03.053 · Cited by 271
Particle-size distributions and seasonal diversity of allergenic and pathogenic fungi in outdoor air
Yamamoto, N., Bibby, K., Qian, J., Hospodsky, D., Rismani-Yazdi, H., Nazaroff, W. W., & Peccia, J. (2012) · The ISME Journal · doi:10.1038/ismej.2012.30 · Cited by 266
Self-citationMeng, Q. Y., Turpin, B. J., Korn, L., Weisel, C. P., Morandi, M., Colome, S., Zhang, J., Stock, T., Spektor, D., Winer, A., et al. (2005) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500378 · Cited by 266
Wang, Y., Bakker, F., de Groot, R., & Wörtche, H. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.03.021 · Cited by 254
Impact of the 2002 Canadian Forest Fires on Particulate Matter Air Quality in Baltimore City
Sapkota, A., Symons, J. M., Kleissl, J., Wang, L., Parlange, M. B., Ondov, J., Breysse, P. N., Diette, G. B., Eggleston, P. A., & Buckley, T. J. (2005) · Environmental Science & Technology · doi:10.1021/es035311z · Cited by 249
Che, W. W., Tso, C. Y., Sun, L., Ip, D. Y. K., Lee, H., Chao, C. Y. H., & Lau, A. K. H. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.06.029 · Cited by 240
Ultrafine particle removal and generation by portable air cleaners
Waring, M. S., Siegel, J. A., & Corsi, R. L. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.02.011 · Cited by 217
Particle Penetration Through Building Cracks
Liu, D.-L., & Nazaroff, W. W. (2003) · Aerosol Science and Technology · doi:10.1080/02786820300927 · Cited by 215
Self-citationWildfire smoke impacts on indoor air quality assessed using crowdsourced data in California
Liang, Y., Sengupta, D., Campmier, M. J., Lunderberg, D. M., Apte, J. S., & Goldstein, A. H. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2106478118 · Cited by 205
Azimi, P., & Stephens, B. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.08.025 · Cited by 202
The mutagenic hazards of settled house dust: a review
Maertens, R. M., Bailey, J., & White, P. A. (2004) · Mutation Research/Reviews in Mutation Research · doi:10.1016/j.mrrev.2004.08.004 · Cited by 199
Penetration of freeway ultrafine particles into indoor environments
Zhu, Y., Hinds, W. C., Krudysz, M., Kuhn, T., Froines, J., & Sioutas, C. (2005) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2004.09.007 · Cited by 193
Estimating the concentration of indoor particles of outdoor origin: A review
Diapouli, E., Chaloulakou, A., & Koutrakis, P. (2013) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2013.791649 · Cited by 173
Estimates of HVAC filtration efficiency for fine and ultrafine particles of outdoor origin
Azimi, P., Zhao, D., & Stephens, B. (2014) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.09.007 · Cited by 172
Waring, M. S., & Wells, J. R. (2015) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.06.062 · Cited by 168
Ji, W., & Zhao, B. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.04.006 · Cited by 158
Bhangar, S., Mullen, N. A., Hering, S. V., Kreisberg, N. M., & Nazaroff, W. W. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00689.x · Cited by 158
Self-citationAir infiltration rate distributions of residences in Beijing
Shi, S., Chen, C., & Zhao, B. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.05.027 · Cited by 159
Chamber bioaerosol study: human emissions of size‐resolved fluorescent biological aerosol particles
Bhangar, S., Adams, R. I., Pasut, W., Huffman, J. A., Arens, E. A., Taylor, J. W., Bruns, T. D., & Nazaroff, W. W. (2015) · Indoor Air · doi:10.1111/ina.12195 · Cited by 169
Self-citationRespiratory aerosols and droplets in the transmission of infectious diseases
Pöhlker, M. L., Pöhlker, C., Krüger, O. O., Förster, J., Berkemeier, T., Elbert, W., Fröhlich‐Nowoisky, J., Pöschl, U., Bagheri, G., Bodenschatz, E., et al. (2023) · Reviews of Modern Physics · doi:10.1103/revmodphys.95.045001 · Cited by 228
Howard-Reed, C. (2003) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.09.012 · Cited by 157
Ben-David, T., & Waring, M. S. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.05.007 · Cited by 159
Thatcher, T. L., Lunden, M. M., Revzan, K. L., Sextro, R. G., & Brown, N. J. (2003) · Aerosol Science and Technology · doi:10.1080/02786820300940 · Cited by 147
Do the plants in functional green walls contribute to their ability to filter particulate matter?
Pettit, T. J., Irga, P. J., Abdo, P., & Torpy, F. R. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.09.004 · Cited by 144
Chen, C., Zhao, B., Cui, W., Dong, L., An, N., & Ouyang, X. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0516 · Cited by 137
Apte, J. S., Bombrun, E., Marshall, J. D., & Nazaroff, W. W. (2012) · Environmental Science & Technology · doi:10.1021/es204021h · Cited by 139
Self-citationDeposition rates on smooth surfaces and coagulation of aerosol particles inside a test chamber
Hussein, T., Hruška, A., Dohányosová, P., Džumbová, L., Hemerka, J., Kulmala, M., & Smolík, J. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.10.059 · Cited by 136
Chen, C., Zhao, B., & Weschler, C. J. (2012) · Epidemiology · doi:10.1097/ede.0b013e31826b800e · Cited by 136
Towards practical indoor air phytoremediation: A review
Pettit, T. J., Irga, P. J., & Torpy, F. R. (2018) · Chemosphere · doi:10.1016/j.chemosphere.2018.06.048 · Cited by 133
Indoor and outdoor particle size characterization at a family house in Espoo–Finland
Hussein, T., Hämeri, K. J., Heikkinen, M. S. A., & Kulmala, M. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.03.011 · Cited by 127
Wallace, L. A. (2003) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.10.003 · Cited by 127
Exploring the consequences of climate change for indoor air quality
Nazaroff, W. W. (2013) · Environmental Research Letters · doi:10.1088/1748-9326/8/1/015022 · Cited by 150
Self-citationIndoor environmental quality benefits of apartment energy retrofits
Noris, F., Adamkiewicz, G., Delp, W. W., Hotchi, T., Russell, M., Singer, B. C., Spears, M., Vermeer, K., & Fisk, W. J. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.07.003 · Cited by 134
Indoor ultrafine particles and childhood asthma: exploring a potential public health concern
Weichenthal, S., Dufresne, A., & Infante‐Rivard, C. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00446.x · Cited by 120
Fisk, W. J. (2015) · Building and Environment · doi:10.1016/j.buildenv.2014.12.024 · Cited by 123
Tippayawong, N., Khuntong, P., Nitatwichit, C., Khunatorn, Y., & Tantakitti, C. (2008) · Building and Environment · doi:10.1016/j.buildenv.2008.02.007 · Cited by 115
Colombi, C., Angius, S., Gianelle, V. L., & Lazzarini, M. (2013) · Atmospheric Environment · doi:10.1016/j.atmosenv.2013.01.035 · Cited by 114
Wallace, L. A., Williams, R. W., Rea, A. W., & Croghan, C. W. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.08.042 · Cited by 113
Nazaroff, W. W., & Weschler, C. J. (2020) · Indoor Air · doi:10.1111/ina.12670 · Cited by 124
Self-citationParticle loading rates for HVAC filters, heat exchangers, and ducts
Waring, M. S., & Siegel, J. A. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2008.00518.x · Cited by 109
How Do Indoor Environments Affect Air Pollution Exposure?
Goldstein, A. H., Nazaroff, W. W., Weschler, C. J., & Williams, J. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.0c05727 · Cited by 126
Self-citationIndoor Emissions as a Primary Source of Airborne Allergenic Fungal Particles in Classrooms
Yamamoto, N., Hospodsky, D., Dannemiller, K. C., Nazaroff, W. W., & Peccia, J. (2015) · Environmental Science & Technology · doi:10.1021/es506165z · Cited by 107
Self-citationUltrafine Particles: Exposure and Source Apportionment in 56 Danish Homes
Bekö, G., Weschler, C. J., Wierzbicka, A., Karottki, D. G., Toftum, J., Loft, S. H., & Clausen, G. (2013) · Environmental Science & Technology · doi:10.1021/es402429h · Cited by 107
Study of atmospheric particulate matter in Buenos Aires city
Bogo, H., Otero, M., Castro, P., Ozafrán, M. J., Kreiner, A. J., Calvo, E. J., & Negri, R. M. (2003) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00977-9 · Cited by 107
Han, Y., Qi, M., Chen, Y., Shen, H., Liu, J., Huang, Y., Chen, H., Liu, W., Wang, X., Liu, J., et al. (2015) · Environmental Pollution · doi:10.1016/j.envpol.2015.04.026 · Cited by 109
Bhangar, S., Huffman, J. A., & Nazaroff, W. W. (2014) · Indoor Air · doi:10.1111/ina.12111 · Cited by 120
Self-citationRespiratory effects of indoor particles in young children are size dependent
Franck, U. F., Herbarth, O., Röder, S. W., Schlink, U., Borte, M., Diez, U., Krämer, U., & Lehmann, I. (2011) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2011.01.001 · Cited by 116
Indoor air quality in a dentistry clinic
Helmis, C. G., Tzoutzas, J., Flocas, H. A., Halios, C. H., Stathopoulou, O. I., Assimakopoulos, V. D., Panis, V., Apostolatou, M., Sgouros, G., & Adam, E. (2007) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2007.01.100 · Cited by 106
Ultrafine particle removal by residential heating, ventilating, and air-conditioning filters
Stephens, B., & Siegel, J. A. (2013) · Indoor Air · doi:10.1111/ina.12045 · Cited by 114
Peng, Z., Deng, W., & Tenorio, R. (2017) · Sustainability · doi:10.3390/su9071180 · Cited by 109
“[10] suggested that the penetration of particles through building cracks would significantly affect indoor air quality, especially for buildings where air exchange through openings or cracks is dominated by pressure differences arising from natural forces.”
BackgroundIndoor inhalation intake fractions of fine particulate matter: review of influencing factors
Hodas, N. O., Loh, M. M., Shin, H., Li, D., Bennett, D. H., McKone, T. E., Jolliet, O., Weschler, C. J., Jantunen, M. J., Lioy, P. J., et al. (2015) · Indoor Air · doi:10.1111/ina.12268 · Cited by 101
Self-citationWaring, M. S. (2014) · Indoor Air · doi:10.1111/ina.12092 · Cited by 98
Influence of natural ventilation rate on indoor PM2.5 deposition
Liu, C., Yang, J., Ji, S., Lu, Y., Wu, P., & Chen, C. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.08.039 · Cited by 95
Sarnat, S. E., Coull, B. A., Ruiz-Rudolph, P., Koutrakis, P., & Suh, H. H. (2006) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2006.10464449 · Cited by 95
Park, H., Cheng, K.-C., Tetteh, A. O., Hildemann, L. M., & Nadeau, K. C. (2016) · Journal of Asthma · doi:10.1080/02770903.2016.1218011 · Cited by 91
Ng, B. F., Xiong, J. W., & Wan, M. P. (2017) · PLoS ONE · doi:10.1371/journal.pone.0178851 · Cited by 105
Fantke, P., Jolliet, O., Evans, J. S., Apte, J. S., Cohen, A., Hänninen, O., Hurley, F., Jantunen, M. J., Jerrett, M., Levy, J. I., et al. (2014) · The International Journal of Life Cycle Assessment · doi:10.1007/s11367-014-0822-2 · Cited by 102
Self-citationBekö, G., Clausen, G., & Weschler, C. J. (2007) · Building and Environment · doi:10.1016/j.buildenv.2007.10.006 · Cited by 104
Johnson, A. M., Waring, M. S., & DeCarlo, P. F. (2016) · Indoor Air · doi:10.1111/ina.12299 · Cited by 94
Shi, S., & Zhao, B. (2014) · Environmental Science & Technology · doi:10.1021/es500235q · Cited by 94
Wheeler, A. J., Wallace, L. A., Kearney, J. P., Ryswyk, K. V., You, H., Kulka, R., Brook, J. R., & Xu, X. (2011) · Aerosol Science and Technology · doi:10.1080/02786826.2011.580798 · Cited by 87
Martuzevičius, D., Grinshpun, S. A., Lee, T., Hu, S., Biswas, P., Reponen, T. A., & LeMasters, G. K. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.05.009 · Cited by 102
Indoor Aerosol Modeling: Basic Principles and Practical Applications
Hussein, T., & Kulmala, M. (2007) · Water Air and Soil Pollution Focus · doi:10.1007/s11267-007-9134-x · Cited by 85
Orch, Z. E., Stephens, B., & Waring, M. S. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.01.006 · Cited by 82
Inhalation intake of ambient air pollution in California's South Coast Air Basin
Marshall, J. D., Granvold, P. W., Hoats, A. S., McKone, T. E., Deakin, E. A., & Nazaroff, W. W. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.03.034 · Cited by 90
Self-citationWeschler, C. J., & Shields, H. C. (2003) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.05.007 · Cited by 77
Fantke, P., Jolliet, O., Apte, J. S., Hodas, N., Evans, J. S., Weschler, C. J., Stylianou, K. S., Jantunen, M. J., & McKone, T. E. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.7b02589 · Cited by 85
Self-citationLong Duration Tests of Room Air Filters in Cigarette Smokers' Homes
Batterman, S., Godwin, C., & Jia, C. (2005) · Environmental Science & Technology · doi:10.1021/es048951q · Cited by 83
Modeling impacts of dynamic ventilation strategies on indoor air quality of offices in six US cities
Rackes, A., & Waring, M. S. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.10.013 · Cited by 74
The effects of ventilation and filtration on indoor PM2.5 in office buildings in four countries
Jones, E. R., Laurent, J. G. C., Young, A. S., MacNaughton, P., Coull, B. A., Spengler, J. D., & Allen, J. G. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107975 · Cited by 85
Ruan, T., & Rim, D. (2019) · Sustainable Cities and Society · doi:10.1016/j.scs.2019.101609 · Cited by 73
Stephens, B., & Siegel, J. A. (2012) · Aerosol Science and Technology · doi:10.1080/02786826.2011.642825 · Cited by 73
Liagkouridis, I., Cousins, I. T., & Cousins, A. P. (2014) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2014.02.005 · Cited by 72
Hussein, T., Korhonen, H., Herrmann, E., Hämeri, K. J., Lehtinen, K. E. J., & Kulmala, M. (2005) · Aerosol Science and Technology · doi:10.1080/02786820500421513 · Cited by 72
Inversely tracking indoor airborne particles to locate their release sources
Zhang, T., Li, H., & Wang, S. (2012) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.03.066 · Cited by 69
Indoor aerosol modeling for assessment of exposure and respiratory tract deposited dose
Hussein, T., Wierzbicka, A., Löndahl, J., Lazaridis, M., & Hänninen, O. (2014) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.07.034 · Cited by 76
Spicknall, I. H., Koopman, J. S., Nicas, M., Pujol, J. M., Li, S., & Eisenberg, J. N. S. (2010) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1000969 · Cited by 81
Brincat, J., Sardella, D., Muscat, A., Decelis, S., Grima, J. N., Valdramidis, V., & Gatt, R. (2016) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2016.01.015 · Cited by 70
Indoor Residence Times of Semivolatile Organic Compounds: Model Estimation and Field Evaluation
Shin, H., McKone, T. E., Tulve, N. S., Clifton, M. S., & Bennett, D. H. (2012) · Environmental Science & Technology · doi:10.1021/es303316d · Cited by 67
Self-citationModeling particle loss in ventilation ducts
Sippola, M. R., & Nazaroff, W. W. (2003) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.07.016 · Cited by 65
Self-citationHodas, N., Meng, Q., Lunden, M. M., Rich, D. Q., Özkaynak, H., Baxter, L. K., Zhang, Q., & Turpin, B. J. (2012) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2012.34 · Cited by 65
Predictors of Indoor Air Concentrations in Smoking and Non-Smoking Residences
Héroux, M.-È., Clark, N., Ryswyk, K. V., Mallick, R., Gilbert, N. L., Harrison, I., Rispler, K., Wang, D., Anastassopoulos, A., Guay, M., et al. (2010) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph7083080 · Cited by 63
Sultan, Z. M., Nilsson, G., & Magee, R. J. (2011) · Science and Technology for the Built Environment · doi:10.1080/10789669.2011.579219 · Cited by 62
Kopperud, R. J., Ferro, A. R., & Hildemann, L. M. (2004) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2004.10470983 · Cited by 61
Xu, B., & Zhu, Y. (2009) · Aerosol Science and Technology · doi:10.1080/02786820802705837 · Cited by 60
Du, L., Batterman, S., Godwin, C., Chin, J.-Y., Parker, E. A., Breen, M. S., Brakefield-Caldwell, W., Robins, T. G., & Lewis, T. C. (2012) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph9124639 · Cited by 60
Stephens, B., Siegel, J. A., & Novoselac, A. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.04.005 · Cited by 61
Mathematical model of particle penetration through smooth/rough building envelop leakages
Tian, L., Zhang, G., Lin, Y., Yu, J., Zhou, J., & Zhang, Q. (2009) · Building and Environment · doi:10.1016/j.buildenv.2008.08.007 · Cited by 57
Rothamer, D. A., Sanders, S. T., Reindl, D. T., & Bertram, T. H. (2021) · Science and Technology for the Built Environment · doi:10.1080/23744731.2021.1944665 · Cited by 57
Gu, P., Li, Z., Ye, Q., Robinson, E. S., Apte, J. S., Robinson, A. L., & Presto, A. A. (2018) · Environmental Science & Technology · doi:10.1021/acs.est.8b03833 · Cited by 72
Particulate Matter, an Intrauterine Toxin Affecting Foetal Development and Beyond
Chen, H., Oliver, B. G. G., Pant, A., Olivera, A., Poronnik, P., Pollock, C. A., & Saad, S. (2021) · Antioxidants · doi:10.3390/antiox10050732 · Cited by 62
Yu, C. K. H., Li, M., Chan, V., & Lai, A. C. K. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.03.004 · Cited by 56
Self-citationBen-David, T., & Waring, M. S. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.10.025 · Cited by 57
Metadata
- Authors
- Riley, W. J., McKone, T. E., Lai, A. C. K., & Nazaroff, W. W.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Riley, William J.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-12-13
- Volume
- 36
- Issue
- 2
- Pages
- 200-207
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W1973118576
- Cited by
- 417
- References
- 33
- Citations by year
- 2026: 8 · 2025: 11 · 2024: 11 · 2023: 10 · 2022: 23 · 2021: 22 · 2020: 29 · 2019: 22 · 2018: 25 · 2017: 21 · 2016: 19 · 2015: 32 · 2014: 27 · 2013: 18 · 2012: 26
- FWCI
- 6.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Environmental Science & Technology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric chemistry and aerosols
- Keywords
- indoor particulate matter, particle size dependence, particle removal mechanism, particle deposition, ventilation filters, office buildings, residential buildings, ventilation rate, particle size distribution, sulfate, elemental carbon, indoor air quality, human exposure
- MeSH terms
- Air Movements, Air Pollutants, Environmental Exposure, Forecasting, Humans, Models, Theoretical, Particle Size, Public Health, Air Pollution, Indoor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.