Arsenic Removal from Bangladesh Tube Well Water with Filter Columns Containing Zerovalent Iron Filings and Sand
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Arsenic removal is often challenging due to high As(III), phosphate, and silicate concentrations and low natural iron concentrations. Application of zerovalent iron is promising, as metallic iron is widely available. However, removal mechanisms remained unclear and currently used removal units with iron have not been tested systematically, partly due to their large size and long operation time. This study investigated smaller filter columns with 3-4 filters, each containing 2.5 g of iron filings and 100-150 g of sand. At a flow rate of 1 L/h, these columns were able to treat 75-90 L of well water with 440 microg/L As, 1.8 mg/L P, 4.7 mg/L Fe, 19 mg/L Si, and 6 mg/L dissolved organic carbon (DOC) to below 50 microg/L As(tot), without addition of an oxidant. As(III) was oxidized in parallel to oxidation of corrosion-released Fe(II) by dissolved oxygen and sorbed on the forming hydrous ferric oxides (HFO). The open filter columns prevented anoxic conditions. DOC did not appear to interfere with arsenic removal. Manganese was reduced after a slight initial increase from 0.3 mg/L to below 0.1 mg/L. About 100 mg of Fe(0)/L of water was required, 3-5 times less than that for larger units with sand and iron turnings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Leupin, O. X., & Hug, S. J. (2005) · Water Research · doi:10.1016/j.watres.2005.02.012 · Cited by 421
Self-citation
Cited by
Global Water Pollution and Human Health
Schwarzenbach, R. P., Egli, T., Hofstetter, T. B., von Gunten, U., & Wehrli, B. (2010) · Annual Review of Environment and Resources · doi:10.1146/annurev-environ-100809-125342 · Cited by 2,076
Deborde, M., & von Gunten, U. (2008) · Water Research · doi:10.1016/j.watres.2007.07.025 · Cited by 2,056
Arsenic contamination, consequences and remediation techniques: A review
Singh, R., Singh, S., Parihar, P., Singh, V. P., & Prasad, S. M. (2015) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2014.10.009 · Cited by 1,099
Katsoyiannis, I. A., Ruettimann, T., & Hug, S. J. (2008) · Environmental Science & Technology · doi:10.1021/es800649p · Cited by 463
Self-citationIron and aluminium based adsorption strategies for removing arsenic from water
Giles, D. E., Mohapatra, M., Issa, T. B., Anand, S., & Singh, P. (2011) · Journal of Environmental Management · doi:10.1016/j.jenvman.2011.07.018 · Cited by 345
Possible treatments for arsenic removal in Latin American waters for human consumption
Litter, M. I., Morgada, M. E., & Bundschuh, J. (2010) · Environmental Pollution · doi:10.1016/j.envpol.2010.01.028 · Cited by 295
Spuhler, D., Andrés Rengifo-Herrera, J., & Pulgarin, C. (2010) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2010.02.010 · Cited by 289
Whole-cell living biosensors—are they ready for environmental application?
Harms, H., Wells, M. C., & van der Meer, J. R. (2006) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-006-0319-4 · Cited by 197
“(6) There is a direct link to solutions of the environmental problem since the development of simple arsenic detection methods is accompanied by the development of simple methods of As(III)/As(V) removal from the water (Leupin et al. 2005) and to efforts to locally implement detection and removal methods (Giger et al.”
MethodSharma, A. K., Tjell, J. C., Sloth, J. J., & Holm, P. E. (2014) · Applied Geochemistry · doi:10.1016/j.apgeochem.2013.11.012 · Cited by 194
Wu, J., Wang, X.-B., & Zeng, R. J. (2017) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2017.03.023 · Cited by 191
“Sulfide and ferrous ions were detected by spectrophotometry using 4-amino-dimethylaniline and o-phenanthroline, respectively [28, 29].”
MethodArsenic Removal with Composite Iron Matrix Filters in Bangladesh: A Field and Laboratory Study
Neumann, A., Kaegi, R., Voegelin, A., Hussam, A., Munir, A. K. M., & Hug, S. J. (2013) · Environmental Science & Technology · doi:10.1021/es305176x · Cited by 189
Self-citationZhang, Q., Du, Q., Hua, M., Jiao, T., Gao, F., & Pan, B. (2013) · Environmental Science & Technology · doi:10.1021/es400919t · Cited by 180
Ma, L., Islam, S. M., Liu, H., Zhao, J., Sun, G., Li, H., Ma, S., & Kanatzidis, M. G. (2017) · Chemistry of Materials · doi:10.1021/acs.chemmater.7b00618 · Cited by 175
Kumar, R., Patel, M., Singh, P., Bundschuh, J., Pittman, C. U., Trakal, L., & Mohan, D. (2019) · Science of The Total Environment · doi:10.1016/j.scitotenv.2019.07.233 · Cited by 172
Dodd, M. C., Vu, N. D., Ammann, A., Le, V. C., Kissner, R., Pham, H. V., Cao, T. H., Berg, M., & von Gunten, U. (2006) · Environmental Science & Technology · doi:10.1021/es0524999 · Cited by 168
Chiew, H., Sampson, M. L., Huch, S., Ken, S., & Bostick, B. C. (2009) · Environmental Science & Technology · doi:10.1021/es803444t · Cited by 109
Katsoyiannis, I. A., Zikoudi, A., & Hug, S. J. (2008) · Desalination · doi:10.1016/j.desal.2007.06.014 · Cited by 81
Self-citationMetallic Iron for Water Treatment: A Critical Review
Noubactep, C. (2013) · CLEAN – Soil, Air, Water · doi:10.1002/clen.201200502 · Cited by 76
Advantages of low pH and limited oxygenation in arsenite removal from water by zero-valent iron
Klas, S., & Kirk, D. W. (2013) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2013.02.044 · Cited by 64
Hug, S. J., Gaertner, D., Roberts, L. C., Schirmer, M., Ruettimann, T., Rosenberg, T. M., Badruzzaman, A. B. M., & Ashraf Ali, M. (2011) · Applied Geochemistry · doi:10.1016/j.apgeochem.2011.03.012 · Cited by 53
Self-citation
Metadata
- Authors
- Leupin, O. X., Hug, S. J., & Badruzzaman, A. B. M.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-09-09
- Volume
- 39
- Issue
- 20
- Pages
- 8032-8037
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2069452071
- Cited by
- 155
- References
- 1
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.