Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 498

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Adsorption of Humic Acid onto Nanoscale Zerovalent Iron and Its Effect on Arsenic Removal

Giasuddin, Abul B. M., Kanel, Sushil R., Choi, Heechul·2007·Environmental Science & Technology

Abstract

Batch experiments were performed to investigate the feasibility of humic acid (HA) removal by synthetic nanoscale zerovalent iron (NZVI) and its interaction with As(III) and As(V), the most poisonous and abundant of groundwater pollutants. High-resolution transmission electron microscopy (HR-TEM) and X-ray diffraction (XRD) were used to characterize the particle size, surface morphology of the pristine NZVI and HA-treated NZVI (NZVI-HA), and the zero valence state of the pristine NZVI. It was determined that HA was completely removed by NZVI (0.3 g/L) within a few minutes, at a wide range of initial pH values (approximately 3.0-12.0). Fourier transform infrared (FTIR) and laser light scattering (zeta potential measurement) studies confirmed that NZVI-HA forms inner-sphere surface complexation at different initial pH conditions. The effects of competing anions showed that there was complete removal of HA in the presence of 10 mM NO(-3) and SO4(2-) whereas HA removal was observed 0%, 18% and 22% in presence of 10 mM H2PO4(2-), HCO(3-) and H4SiO4(0), respectively. However, the presence of 2 mM CA2+ and Mg2+ enhanced HA removal from 17 mg g(-1) to 76 mg g(-1) and 55 mg g(-1), respectively. Long-term time-resolved studies of XRD and field emission scanning electron microscopy (FE-SEM) with energy-dispersive X-ray (EDX) revealed the formation of various types of new iron oxides (magnetite, maghemite, and lepidocrocites) during the continuous reaction of HA in the presence of water and NZVI at 1, 30, 60, and 90 days. In addition, the surface-area-normalized rate constant (ksa) of adsorption of As(III) and As(V) onto NZVI was reduced in the presence of HA (20 mg L(-1)), from 100% to 43% and 68%, respectively. Our results show the potential use of NZVI in removing HA and its possible effects on arsenic removal during the application of NZVI in groundwater remediation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es0616534

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

Metadata

Authors
Giasuddin, A. B. M., Kanel, S. R., & Choi, H.
Venue
Environmental Science & Technology
Published
2007-02-17
Volume
41
Issue
6
Pages
2022-2027
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W1968073275
Cited by
498
References
18
FWCI
19.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.