The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Top Down Characterization of Larger Proteins (45 kDa) by Electron Capture Dissociation Mass Spectrometry
Abstract
The structural characterization of proteins expressed from the genome is a major problem in proteomics. The solution to this problem requires the separation of the protein of interest from a complex mixture, the identification of its DNA-predicted sequence, and the characterization of sequencing errors and posttranslational modifications. For this, the "top down" mass spectrometry (MS) approach, extended by the greatly increased protein fragmentation from electron capture dissociation (ECD), has been applied to characterize proteins involved in the biosynthesis of thiamin, Coenzyme A, and the hydroxylation of proline residues in proteins. With Fourier transform (FT) MS, electrospray ionization (ESI) of a complex mixture from an E. coli cell extract gave 102 accurate molecular weight values (2-30 kDa), but none corresponding to the predicted masses of the four desired enzymes for thiamin biosynthesis (GoxB, ThiS, ThiG, and ThiF). MS/MS of one ion species (representing approximately 1% of the mixture) identified it with the DNA-predicted sequence of ThiS, although the predicted and measured molecular weights were different. Further purification yielded a 2-component mixture whose ECD spectrum characterized both proteins simultaneously as ThiS and ThiG, showing an additional N-terminal Met on the 8 kDa ThiS and removal of an N-terminal Met and Ser from the 27 kDa ThiG. For a second system, the molecular weight of the 45 kDa phosphopantothenoylcysteine synthetase/decarboxylase (CoaBC), an enzyme involved in Coenzyme A biosynthesis, was 131 Da lower than that of the DNA prediction; the ECD spectrum showed that this is due to the removal of the N-terminal Met. For a third system, viral prolyl 4-hydroxylase (26 kDa), ECD showed that multiple molecular ions (+98, +178, etc.) are due to phosphate noncovalent adducts, and MS/MS pinpointed the overall mass discrepancy of 135 Da to removal of the initiation Met (131 Da) and to formation of disulfide bonds (2 x 2 Da) at C32-C49 and C143-C147, although 10 S-S positions were possible. In contrast, "bottom up" proteolysis characterization of the CoaBC and the P4H proteins was relatively unsuccessful. The addition of ECD substantially increases the capabilities of top down FTMS for the detailed structural characterization of large proteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Self-citationCOLLAGENS: Molecular Biology, Diseases, and Potentials for Therapy
Prockop, D. J., & Kivirikko, K. I. (1995) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.64.070195.002155 · Cited by 1,623
Error-Tolerant Identification of Peptides in Sequence Databases by Peptide Sequence Tags
Mann, M., & Wilm, M. (1994) · Analytical Chemistry · doi:10.1021/ac00096a002 · Cited by 1,468
Electron Capture Dissociation for Structural Characterization of Multiply Charged Protein Cations
Zubarev, R. A., Horn, D. M., Fridriksson, E. K., Kelleher, N. L., Kruger, N. A., Lewis, M. A., Carpenter, B. K., & McLafferty, F. W. (2000) · Analytical Chemistry · doi:10.1021/ac990811p · Cited by 986
Self-citationInfrared Multiphoton Dissociation of Large Multiply Charged Ions for Biomolecule Sequencing
Little, D. P., Speir, J. P., Senko, M. W., O'Connor, P. B., & McLafferty, F. W. (1994) · Analytical Chemistry · doi:10.1021/ac00090a004 · Cited by 753
Self-citationGauthier, J. W., Trautman, T. R., & Jacobson, D. B. (1991) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)80678-9 · Cited by 645
Tailored excitation for Fourier transform ion cyclotron mass spectrometry
Marshall, A. G., Wang, T. C. L., & Ricca, T. L. (1985) · Journal of the American Chemical Society · doi:10.1021/ja00312a015 · Cited by 631
Top Down versus Bottom Up Protein Characterization by Tandem High-Resolution Mass Spectrometry
Kelleher, N. L., Lin, H. Y., Valaskovic, G. A., Aaserud, D. J., Fridriksson, E. K., & McLafferty, F. W. (1999) · Journal of the American Chemical Society · doi:10.1021/ja973655h · Cited by 605
Self-citationZubarev, R. A., Kruger, N. A., Fridriksson, E. K., Lewis, M. A., Horn, D. M., Carpenter, B. K., & McLafferty, F. W. (1999) · Journal of the American Chemical Society · doi:10.1021/ja981948k · Cited by 557
Self-citationAttomole Protein Characterization by Capillary Electrophoresis-Mass Spectrometry
Valaskovic, G. A., Kelleher, N. L., & McLafferty, F. W. (1996) · Science · doi:10.1126/science.273.5279.1199 · Cited by 398
Self-citationKelleher, N. L., Zubarev, R. A., Bush, K., Furie, B., Furie, B. C., McLafferty, F. W., & Walsh, C. T. (1999) · Analytical Chemistry · doi:10.1021/ac990684x · Cited by 368
Self-citationElectron capture dissociation of singly and multiply phosphorylated peptides
Stensballe, A., Jensen, O. N., Olsen, J. V., Haselmann, K. F., & Zubarev, R. A. (2000) · Rapid Communications in Mass Spectrometry · doi:10.1002/1097-0231(20001015)14:19<1793::aid-rcm95>3.0.co;2-q · Cited by 348
Tandem Mass Spectrometry of Large Biomolecule Ions by Blackbody Infrared Radiative Dissociation
Price, W. D., Schnier, P. D., & Williams, E. R. (1996) · Analytical Chemistry · doi:10.1021/ac951038a · Cited by 314
Thiamin biosynthesis in prokaryotes
Begley, T. P., Downs, D. M., Ealick, S. E., McLafferty, F. W., Van Loon, A. P. G. M., Taylor, S., Campobasso, N., Chiu, H.-J., Kinsland, C., Reddick, J. J., et al. (1999) · Archives of Microbiology · doi:10.1007/s002030050713 · Cited by 292
Self-citationPostseismic Rebound in Fault Step-Overs Caused by Pore Fluid Flow
Peltzer, G., Rosen, P., Rogez, F., & Hudnut, K. (1996) · Science · doi:10.1126/science.273.5279.1202 · Cited by 290
Mørtz, E., O'Connor, P. B., Roepstorff, P., Kelleher, N. L., Wood, T. D., McLafferty, F. W., & Mann, M. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.16.8264 · Cited by 220
Self-citationMcLafferty, F. W., Fridriksson, E. K., Horn, D. M., Lewis, M. A., & Zubarev, R. A. (1999) · Science · doi:10.1126/science.284.5418.1289 · Cited by 166
Self-citationUse of mass spectrometry-derived data to annotate nucleotide and protein sequence databases
Mann, M., & Pandey, A. (2001) · Trends in Biochemical Sciences · doi:10.1016/s0968-0004(00)01726-6 · Cited by 123
Native disulfide bond formation in proteins
Woycechowsky, K. J., & Raines, R. T. (2000) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(00)00128-9 · Cited by 120
Andersen, J., Svensson, B., & Roepstorff, P. (1996) · Nature Biotechnology · doi:10.1038/nbt0496-449 · Cited by 113
Chowdhury, S. K., Katta, V., Beavis, R. C., & Chait, B. T. (1990) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(90)85018-h · Cited by 111
Protein Molecular Mass to 1 Da by 13C, 15N Double-Depletion and FT-ICR Mass Spectrometry
Marshall, A. G., Senko, M. W., Li, W., Li, M., Dillon, S. R., Guan, S., & Logan, T. M. (1997) · Journal of the American Chemical Society · doi:10.1021/ja9630046 · Cited by 110
An Unconventional Role for Cytoplasmic Disulfide Bonds in Vaccinia Virus Proteins
Locker, J. K., & Griffiths, G. W. (1999) · The Journal of Cell Biology · doi:10.1083/jcb.144.2.267 · Cited by 83
From primary structure to function: biological insights from large-molecule mass spectra
Kelleher, N. L. (2000) · Chemistry & Biology · doi:10.1016/s1074-5521(00)00081-8 · Cited by 32
Cited by
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Orbitrap mass spectrometry: Instrumentation, ion motion and applications
Perry, R. H., Cooks, R. G., & Noll, R. J. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20186 · Cited by 514
The role of electron capture dissociation in biomolecular analysis
Cooper, H. J., Håkansson, K., & Marshall, A. G. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20014 · Cited by 514
Proteomics by FTICR mass spectrometry: Top down and bottom up
Bogdanov, B., & Smith, R. D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20015 · Cited by 447
Reactions of polypeptide ions with electrons in the gas phase
Zubarev, R. A. (2003) · Mass Spectrometry Reviews · doi:10.1002/mas.10042 · Cited by 431
Metadata
- Authors
- Ge, Y., Lawhorn, B. G., ElNaggar, M., Strauss, E., Park, J.-H., Begley, T. P., & McLafferty, F. W.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-01-01
- Volume
- 124
- Issue
- 4
- Pages
- 672-678
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2004558299
- Cited by
- 353
- References
- 25
- FWCI
- 14.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.