The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Enhanced Fluorescence Cyanide Detection at Physiologically Lethal Levels: Reduced ICT-Based Signal Transduction
Open accessAbstract
Three water-soluble fluorescent probes have been specifically designed to determine free cyanide concentrations up to physiologically lethal levels, >20 microM. The probes have been designed in such a way as to afford many notable sensing features, which render them unique with regard to signal transduction, photophysical characteristics, and their application to physiological cyanide determination and safeguard. The probes are readily able to reversibly bind free aqueous cyanide with dissociation constants around 4 microM3. Subsequent cyanide binding modulates the intramolecular charge transfer within the probes, a change in the electronic properties within the probes, resulting in enhanced fluorescence optical signals as a function of increased solution cyanide concentration. The ground-state chelation with cyanide produces wavelength shifts, which also enable the probes to sense cyanide in both an excitation and emission ratiometric manner, in addition to enhanced fluorescence signaling. This has enabled a generic cyanide sensing platform to be realized that is not dependent on fluorescent probe concentration, probe photodegradation, or fluctuations in the intensity of any employed excitation sources, ideal for remote cyanide sensing applications. Further, the >600 nm fluorescence emission of the probes potentially allows for enhanced fluorescence ratiometric cyanide sensing in the optical window of tissues and blood, facilitating their use for the transdermal monitoring of cyanide for mammalian safeguard or postmortem in fire victims, both areas of active research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Self-citationQUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSIS
Richards-Kortum, R., & Sevick-Muraca, E. (1996) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.47.1.555 · Cited by 1,172
Elevated Blood Cyanide Concentrations in Victims of Smoke Inhalation
Baud, F. J., Barriot, P., Toffis, V., Riou, B., Vicaut, E., Lecarpentier, Y., Bourdon, R., Astier, A., & Bismuth, C. (1991) · New England Journal of Medicine · doi:10.1056/nejm199112193252502 · Cited by 478
Luminescence Lifetime-Based Sensor for Cyanide and Related Anions
Anzenbacher, Tyson, D. S., Jursíková, K., & Castellano, F. N. (2002) · Journal of the American Chemical Society · doi:10.1021/ja0259180 · Cited by 460
Topics in Fluorescence Spectroscopy: Probe Design and Chemical Sensing
(1994) · Springer eBooks · doi:10.1007/b112911 · Cited by 303
Cytochrome and respiratory enzymes
Keilin, D. (1929) · Proceedings of the Royal Society of London. Series B, Containing Papers of a Biological Character · doi:10.1098/rspb.1929.0009 · Cited by 282
Optical halide sensing using fluorescence quenching: theory, simulations and applications - a review
Geddes, C. D. (2001) · Measurement Science and Technology · doi:10.1088/0957-0233/12/9/201 · Cited by 271
Self-citationProgress in Boronic Acid-Based Fluorescent Glucose Sensors
Fang, H., Kaur, G., & Wang, B. (2004) · Journal of Fluorescence · doi:10.1023/b:jofl.0000039336.51399.3b · Cited by 245
Determination of Cyanide in Whole Blood by Capillary Gas Chromatography with Cryogenic Oven Trapping
Ishii, A., Seno, H., Watanabe-Suzuki, K., Suzuki, O., & Kumazawa, T. (1998) · Analytical Chemistry · doi:10.1021/ac980498b · Cited by 163
Badugu, R., Lakowicz, J. R., & Geddes, C. D. (2003) · Journal of Fluorescence · doi:10.1023/a:1026103804104 · Cited by 122
Self-citation
Cited by
Sub-nanometre sized metal clusters: from synthetic challenges to the unique property discoveries
Lu, Y., & Chen, W. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15325d · Cited by 1,152
Sensors for the optical detection ofcyanide ion
Xu, Z., Chen, X., Kim, H. N., & Yoon, J. (2010) · Chem. Soc. Rev. · doi:10.1039/b907368j · Cited by 1,121
A Selective Fluorescent Sensor for Imaging Cd2+ in Living Cells
Peng, X., Du, J., Fan, J., Wang, J., Wu, Y., Zhao, J., Sun, S., & Xu, T. (2007) · Journal of the American Chemical Society · doi:10.1021/ja0643319 · Cited by 617
Santos-Figueroa, L. E., Moragues, M. E., Climent, E., Agostini, A., Martínez-Máñez, R., & Sancenón, F. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35429f · Cited by 594
Boronic acid building blocks: tools for sensing and separation
Nishiyabu, R., Kubo, Y., James, T. D., & Fossey, J. S. (2011) · Chemical Communications · doi:10.1039/c0cc02920c · Cited by 414
Moragues, M. E., Martínez-Máñez, R., & Sancenón, F. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00015a · Cited by 386
Boron based anion receptors as sensors
Galbraith, E., & James, T. D. (2010) · Chemical Society Reviews · doi:10.1039/b926165f · Cited by 377
Functional hyperbranched polymers with advanced optical, electrical and magnetic properties
Wu, W., Tang, R., Li, Q., & Li, Z. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00224e · Cited by 372
Carbohydrate recognition by boronolectins, small molecules, and lectins
Jin, S., Cheng, Y., Reid, S., Li, M., & Wang, B. (2010) · Medicinal Research Reviews · doi:10.1002/med.20155 · Cited by 305
Ekmekci, Z., Yilmaz, M. D., & Akkaya, E. U. (2008) · Organic Letters · doi:10.1021/ol702823u · Cited by 302
Zeng, Q., Cai, P., Li, Z., Qin, J., & Tang, B. Z. (2008) · Chemical Communications · doi:10.1039/b717764j · Cited by 297
Chen, X., Nam, S.-W., Kim, G.-H., Song, N., Jeong, Y., Shin, I., Kim, S. K., Kim, J., Park, S., & Yoon, J. (2010) · Chemical Communications · doi:10.1039/c0cc03398g · Cited by 293
Goswami, S., Sen, D., & Das, N. K. (2010) · Organic Letters · doi:10.1021/ol9029066 · Cited by 270
Shao, N., Jin, J., Wang, H., Zheng, J., Yang, R., Chan, W., & Abliz, Z. (2010) · Journal of the American Chemical Society · doi:10.1021/ja908215t · Cited by 268
Zhang, W., Huang, T., Li, J., Sun, P., Wang, Y., Shi, W., Han, W., Wang, W., Fan, Q., & Huang, W. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b02597 · Cited by 80
Metadata
- Authors
- Badugu, R., Lakowicz, J. R., & Geddes, C. D.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-02-16
- Volume
- 127
- Issue
- 10
- Pages
- 3635-3641
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2062098101
- Cited by
- 392
- References
- 17
- FWCI
- 7.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.