The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In Vivo Monitoring of Mercury Ions Using a Rhodamine-Based Molecular Probe
Abstract
Exposure to mercury causes severe damage to various tissues and organs in humans. Concern over mercury toxicity has encouraged the development of efficient, sensitive, and selective methods for the in vivo detection of mercury. Although a variety of chemosensors have been exploited for this purpose, no in vivo monitoring systems have been described to date. In this report, we describe an irreversible rhodamine chemosensor-based, real-time monitoring system to detect mercury ions in living cells and, in particular, vertebrate organisms. The chemosensor responds rapidly, irreversibly, and stoichiometrically to mercury ions in aqueous media at room temperature. The results of experiments with mammalian cells and zebrafish show that the mercury chemosensor is cell and organism permeable and that it responds selectively to mercury ions over other metal ions. In addition, real-time monitoring of mercury-ion uptake by cells and zebrafish using this chemosensor shows that saturation of mercury-ion uptake occurs within 20-30 min in cells and organisms. Finally, accumulation of mercury ions in zebrafish tissue and organs is readily detected by using this rhodamine-based chemosensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The toxicology of mercury—current exposures and clinical manifestations
Clarkson, T. W., Magos, L., & Myers, G. J. (2003) · New England Journal of Medicine · doi:10.1056/nejmra022471 · Cited by 1,766
Cited by
A new trend in rhodamine-based chemosensors: application of spirolactam ring-opening to sensing ions
Kim, H. N., Lee, M. H., Kim, H. J., Kim, J. S., & Yoon, J. (2008) · Chemical Society Reviews · doi:10.1039/b802497a · Cited by 1,649
Zhao, Y., Zhang, X.-B., Han, Z.-X., Qiao, L., Li, C.-Y., Jian, L.-X., Shen, G.-L., & Yu, R.-Q. (2009) · Analytical Chemistry · doi:10.1021/ac901127n · Cited by 455
Hybrid Rhodamine Fluorophores in the Visible/NIR Region for Biological Imaging
Wang, L., Du, W., Hu, Z., Uvdal, K., Li, L., & Huang, W. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201901061 · Cited by 348
Ratiometric Detection of Cr3+and Hg2+by a Naphthalimide-Rhodamine Based Fluorescent Probe
Mahato, P., Saha, S., Suresh, E., Di Liddo, R., Parnigotto, P. P., Conconi, M. T., Kesharwani, M. K., Ganguly, B., & Das, A. (2012) · Inorganic Chemistry · doi:10.1021/ic202073q · Cited by 319
Ye, M., Xiang, Y., Gong, J., Wang, X., Mao, Z., & Liu, Z. (2023) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2022.130612 · Cited by 37
Metadata
- Authors
- Ko, S.-K., Yang, Y.-K., Tae, J., & Shin, I.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-10-06
- Volume
- 128
- Issue
- 43
- Pages
- 14150-14155
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2063155405
- Cited by
- 509
- References
- 1
- FWCI
- 13.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In Vivo Monitoring of Mercury Ions Using a Rhodamine-Based Molecular Probe. https://app.cochat.ai/papers/10.1021/ja065114a
- The paper
- Ko, S.-K., Yang, Y.-K., Tae, J., & Shin, I. (2006). In Vivo Monitoring of Mercury Ions Using a Rhodamine-Based Molecular Probe. Journal of the American Chemical Society. https://doi.org/10.1021/ja065114a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.