The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In Vivo Monitoring of Mercury Ions Using a Rhodamine-Based Molecular Probe
Abstract
Exposure to mercury causes severe damage to various tissues and organs in humans. Concern over mercury toxicity has encouraged the development of efficient, sensitive, and selective methods for the in vivo detection of mercury. Although a variety of chemosensors have been exploited for this purpose, no in vivo monitoring systems have been described to date. In this report, we describe an irreversible rhodamine chemosensor-based, real-time monitoring system to detect mercury ions in living cells and, in particular, vertebrate organisms. The chemosensor responds rapidly, irreversibly, and stoichiometrically to mercury ions in aqueous media at room temperature. The results of experiments with mammalian cells and zebrafish show that the mercury chemosensor is cell and organism permeable and that it responds selectively to mercury ions over other metal ions. In addition, real-time monitoring of mercury-ion uptake by cells and zebrafish using this chemosensor shows that saturation of mercury-ion uptake occurs within 20-30 min in cells and organisms. Finally, accumulation of mercury ions in zebrafish tissue and organs is readily detected by using this rhodamine-based chemosensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The toxicology of mercury—current exposures and clinical manifestations
Clarkson, T. W., Magos, L., & Myers, G. J. (2003) · New England Journal of Medicine · doi:10.1056/nejmra022471 · Cited by 1,766
Cited by
Tools and Tactics for the Optical Detection of Mercuric Ion
Nolan, E. M., & Lippard, S. J. (2008) · Chemical Reviews · doi:10.1021/cr068000q · Cited by 2,345
Luminescent Chemodosimeters for Bioimaging
Yang, Y., Zhao, Q., Feng, W., & Li, F. (2013) · Chemical Reviews · doi:10.1021/cr2004103 · Cited by 2,236
Self-citationMetals in Neurobiology: Probing Their Chemistry and Biology with Molecular Imaging
Que, E. L., Domaille, D. W., & Chang, C. J. (2008) · Chemical Reviews · doi:10.1021/cr078203u · Cited by 2,061
Reaction-based small-molecule fluorescent probes for chemoselective bioimaging
Chan, J., Dodani, S. C., & Chang, C. J. (2012) · Nature Chemistry · doi:10.1038/nchem.1500 · Cited by 1,883
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
A new trend in rhodamine-based chemosensors: application of spirolactam ring-opening to sensing ions
Kim, H. N., Lee, M. H., Kim, H. J., Kim, J. S., & Yoon, J. (2008) · Chemical Society Reviews · doi:10.1039/b802497a · Cited by 1,649
Fluoro- and Chromogenic Chemodosimeters for Heavy Metal Ion Detection in Solution and Biospecimens
Quang, D. T., & Kim, J. S. (2010) · Chemical Reviews · doi:10.1021/cr100154p · Cited by 1,355
Synthetic fluorescent sensors for studying the cell biology of metals
Domaille, D. W., Que, E. L., & Chang, C. J. (2008) · Nature Chemical Biology · doi:10.1038/nchembio.69 · Cited by 1,081
A Ratiometric Fluorescent Probe Based on FRET for Imaging Hg 2+ Ions in Living Cells
Zhang, X., Xiao, Y., & Qian, X. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200803246 · Cited by 800
Xu, Z., Baek, K.-H., Kim, H. N., Cui, J., Qian, X., Spring, D. R., Shin, I., & Yoon, J. (2010) · Journal of the American Chemical Society · doi:10.1021/ja907334j · Cited by 692
Self-citationDu, J., Hu, M., Fan, J., & Peng, X. (2012) · Chemical Society Reviews · doi:10.1039/c2cs00004k · Cited by 688
Liu, J., & Lu, Y. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200702006 · Cited by 593
Zhao, Y., Zhang, X.-B., Han, Z.-X., Qiao, L., Li, C.-Y., Jian, L.-X., Shen, G.-L., & Yu, R.-Q. (2009) · Analytical Chemistry · doi:10.1021/ac901127n · Cited by 455
“Turn-on” fluorescent sensing with “reactive” probes
Eun Jun, M., Roy, B., & Han Ahn, K. (2011) · Chemical Communications · doi:10.1039/c1cc00014d · Cited by 434
Turn-On and Ratiometric Mercury Sensing in Water with a Red-Emitting Probe
Nolan, E. M., & Lippard, S. J. (2007) · Journal of the American Chemical Society · doi:10.1021/ja068879r · Cited by 428
Fluorescent sensor based models for the detection of environmentally-related toxic heavy metals
Rasheed, T., Bilal, M., Nabeel, F., Iqbal, H. M. N., Li, C., & Zhou, Y. (2018) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.09.126 · Cited by 396
FRET-based sensor for imaging chromium(iii) in living cells
Zhou, Z., Yu, M., Yang, H., Huang, K., Li, F., Yi, T., & Huang, C. (2008) · Chemical Communications · doi:10.1039/b801503a · Cited by 379
Hybrid Rhodamine Fluorophores in the Visible/NIR Region for Biological Imaging
Wang, L., Du, W., Hu, Z., Uvdal, K., Li, L., & Huang, W. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201901061 · Cited by 348
Zeng, S., Liu, X., Kafuti, Y. S., Kim, H., Wang, J., Peng, X., Li, H., & Yoon, J. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00799a · Cited by 341
Elemental and Chemically Specific X-ray Fluorescence Imaging of Biological Systems
Pushie, M. J., Pickering, I. J., Korbas, M., Hackett, M. J., & George, G. N. (2014) · Chemical Reviews · doi:10.1021/cr4007297 · Cited by 332
Ojida, A., Takashima, I., Kohira, T., Nonaka, H., & Hamachi, I. (2008) · Journal of the American Chemical Society · doi:10.1021/ja803262w · Cited by 330
Ratiometric Detection of Cr3+and Hg2+by a Naphthalimide-Rhodamine Based Fluorescent Probe
Mahato, P., Saha, S., Suresh, E., Di Liddo, R., Parnigotto, P. P., Conconi, M. T., Kesharwani, M. K., Ganguly, B., & Das, A. (2012) · Inorganic Chemistry · doi:10.1021/ic202073q · Cited by 319
A Highly Selective DNAzyme Sensor for Mercuric Ions
Hollenstein, M., Hipolito, C., Lam, C., Dietrich, D., & Perrin, D. M. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200800960 · Cited by 317
Yang, Y.-K., Cho, H. J., Lee, J., Shin, I., & Tae, J. (2009) · Organic Letters · doi:10.1021/ol802822t · Cited by 276
Self-citationLiu, Q., Peng, J., Sun, L., & Li, F. (2011) · ACS Nano · doi:10.1021/nn202620u · Cited by 263
Taki, M., Iyoshi, S., Ojida, A., Hamachi, I., & Yamamoto, Y. (2010) · Journal of the American Chemical Society · doi:10.1021/ja100714p · Cited by 253
Ye, M., Xiang, Y., Gong, J., Wang, X., Mao, Z., & Liu, Z. (2023) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2022.130612 · Cited by 37
Metadata
- Authors
- Ko, S.-K., Yang, Y.-K., Tae, J., & Shin, I.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-10-06
- Volume
- 128
- Issue
- 43
- Pages
- 14150-14155
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2063155405
- Cited by
- 509
- References
- 1
- FWCI
- 13.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.