The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Fluorescent Biomembrane Probe for Ratiometric Detection of Apoptosis
Abstract
Herein, we developed the first ratiometric fluorescent probe for apoptosis detection. This probe incorporates selectively into the outer leaflet of the cell plasma membrane and senses the loss of the plasma membrane asymmetry occurring during the early steps of apoptosis. The high specificity to the plasma membranes was achieved by introduction into the probe of a membrane anchor, composed of a zwitterionic group and a long (dodecyl) hydrophobic tail. The fluorescence reporter of this probe is 4'-(diethylamino)-3-hydroxyflavone, which exhibits excited-state intramolecular proton transfer (ESIPT), resulting in two-band emission highly sensitive to the lipid composition of the biomembranes. Fluorescence spectroscopy, flow cytometry, and microscopy measurements show that the ratio of the two emission bands of the probe changes dramatically in response to apoptosis. This response reflects the changes in the lipid composition of the outer leaflet of the cell plasma membrane because of the exposure of the anionic phospholipids from the inner leaflet at the early steps of apoptosis. Being ratiometric, the response of the new probe can be easily quantified on an absolute scale. This allows monitoring by laser scanning confocal microscopy the degree and spatial distribution of the apoptotic changes at the cell plasma membranes, a feature that can be hardly achieved with the commonly used fluorescently labeled annexin V assay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vermes, I., Haanen, C., Steffens-Nakken, H., & Reutellingsperger, C. (1995) · Journal of Immunological Methods · doi:10.1016/0022-1759(95)00072-i · Cited by 5,410
Martin, S. J., Reutelingsperger, C. P., McGahon, A. J., Rader, J. A., van Schie, R. C., LaFace, D. M., & Green, D. R. (1995) · The Journal of experimental medicine · doi:10.1084/jem.182.5.1545 · Cited by 2,824
A receptor for phosphatidylserine-specific clearance of apoptotic cells
Fadok, V. A., Bratton, D. L., Rose, D. M., Pearson, A., Ezekewitz, R. A. B., & Henson, P. M. (2000) · Nature · doi:10.1038/35011084 · Cited by 1,491
Pathophysiologic Implications of Membrane Phospholipid Asymmetry in Blood Cells
Zwaal, R. F. A., & Schroit, A. J. (1997) · Blood · doi:10.1182/blood.v89.4.1121 · Cited by 1,340
Cellular stress response and apoptosis in cancer therapy
Herr, I., & Debatin, K.-M. (2001) · Blood · doi:10.1182/blood.v98.9.2603 · Cited by 800
Excited state proton-transfer spectroscopy of 3-hydroxyflavone and quercetin
Sengupta, P. K., & Kasha, M. (1979) · Chemical Physics Letters · doi:10.1016/0009-2614(79)87221-8 · Cited by 617
Phosphatidylserine, a death knell
Schlegel, R. A., & Williamson, P. (2001) · Cell Death & Differentiation · doi:10.1038/sj.cdd.4400817 · Cited by 361
Ntziachristos, V., Schellenberger, E. A., Ripoll, J., Yessayan, D., Graves, E., Bogdanov, A., Josephson, L., & Weissleder, R. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0401137101 · Cited by 348
Bimodal Distribution and Fluorescence Response of Environment-Sensitive Probes in Lipid Bilayers
Klymchenko, A. S., Duportail, G., Demchenko, A. P., & Mély, Y. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74344-1 · Cited by 144
Self-citationAsymmetric Distribution of Phospholipids in Biomembranes
Yamaji‐Hasegawa, A., & Tsujimoto, M. (2006) · Biological and Pharmaceutical Bulletin · doi:10.1248/bpb.29.1547 · Cited by 144
Cited by
New sensing mechanisms for design of fluorescent chemosensors emerging in recent years
Wu, J., Liu, W., Ge, J., Zhang, H., & Wang, P. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00224k · Cited by 1,858
Small molecule-based ratiometric fluorescence probes for cations, anions, and biomolecules
Lee, M. H., Kim, J. S., & Sessler, J. L. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00280f · Cited by 1,642
Excited-state intramolecular proton-transfer (ESIPT) based fluorescence sensors and imaging agents
Sedgwick, A. C., Wu, L., Han, H.-H., Bull, S. D., He, X.-P., James, T. D., Sessler, J. L., Tang, B. Z., Tian, H., & Yoon, J. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00185e · Cited by 1,569
Klymchenko, A. S. (2017) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00517 · Cited by 1,220
Self-citationZhao, J., Ji, S., Chen, Y., Guo, H., & Yang, P. (2012) · Phys. Chem. Chem. Phys. · doi:10.1039/c2cp23144a · Cited by 1,192
Excited-state proton coupled charge transfer modulated by molecular structure and media polarization
Demchenko, A. P., Tang, K.-C., & Chou, P.-T. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35195a · Cited by 763
Self-citationZhang, K., Zhou, H., Mei, Q., Wang, S., Guan, G., Liu, R., Zhang, J., & Zhang, Z. (2011) · Journal of the American Chemical Society · doi:10.1021/ja2015873 · Cited by 547
Fluorescent Probes for Lipid Rafts: From Model Membranes to Living Cells
Klymchenko, A. S., & Kreder, R. (2014) · Chemistry & Biology · doi:10.1016/j.chembiol.2013.11.009 · Cited by 514
Self-citationSwitchable Nile Red-Based Probe for Cholesterol and Lipid Order at the Outer Leaflet of Biomembranes
Kucherak, O. A., Oncul, S., Darwich, Z., Yushchenko, D. A., Arntz, Y., Didier, P., Mély, Y., & Klymchenko, A. S. (2010) · Journal of the American Chemical Society · doi:10.1021/ja100351w · Cited by 427
Self-citationDesign and Application of Fluorescent Probes to Detect Cellular Physical Microenvironments
Ma, J., Sun, R., Xia, K., Xia, Q., Liu, Y., & Zhang, X. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00573 · Cited by 408
Monitoring Biophysical Properties of Lipid Membranes by Environment-Sensitive Fluorescent Probes
Demchenko, A. P., Mély, Y., Duportail, G., & Klymchenko, A. S. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2009.02.012 · Cited by 381
Self-citationFeng, Q.-M., Shen, Y.-Z., Li, M.-X., Zhang, Z.-L., Zhao, W., Xu, J.-J., & Chen, H.-Y. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03670 · Cited by 320
Danylchuk, D. I., Jouard, P.-H., & Klymchenko, A. S. (2021) · Journal of the American Chemical Society · doi:10.1021/jacs.0c10972 · Cited by 298
Self-citationYao, J., Zhang, K., Zhu, H., Ma, F., Sun, M., Yu, H., Sun, J., & Wang, S. (2013) · Analytical Chemistry · doi:10.1021/ac401011r · Cited by 286
Guo, L., Tian, M., Zhang, Z., Lu, Q., Liu, Z., Niu, G., & Yu, X. (2021) · Journal of the American Chemical Society · doi:10.1021/jacs.0c12323 · Cited by 269
Metadata
- Authors
- Shynkar, V. V., Klymchenko, A. S., Kunzelmann, C., Duportail, G., Muller, C. D., Demchenko, A. P., Freyssinet, J.-M., & Mely, Y.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-01-27
- Volume
- 129
- Issue
- 7
- Pages
- 2187-2193
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2037098558
- Cited by
- 335
- References
- 21
- FWCI
- 5.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.