The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Simultaneous Fluorescence Sensing of Cys and GSH from Different Emission Channels
Abstract
A chlorinated coumarin-hemicyanine dye with three potential reaction sites was exploited as fluorescent probe for biothiols. The Cys-induced substitution-rearrangement-cyclization, Hcy-induced substitution-rearrangement, and GSH-induced substitution-cyclizatioin cascades lead to the corresponding amino-coumarin, amino-coumarin-hemicyanine, thiol-coumarin with distinct photophysical properties, enabling Cys and GSH to be selectively detected from different emission channels at two different excitation wavelengths.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new generation of Ca2+ indicators with greatly improved fluorescence properties.
Grynkiewicz, G., Poenie, M., & Tsien, R. Y. (1985) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)83641-4 · Cited by 21,607
Structure, mechanism and regulation of peroxiredoxins
Wood, Z. A., Schröder, E., Robin Harris, J., & Poole, L. B. (2003) · Trends in Biochemical Sciences · doi:10.1016/s0968-0004(02)00003-8 · Cited by 2,544
The importance of glutathione in human disease
Townsend, D. M., Tew, K. D., & Tapiero, H. (2003) · Biomedicine & Pharmacotherapy · doi:10.1016/s0753-3322(03)00043-x · Cited by 2,004
Oxidized Redox State of Glutathione in the Endoplasmic Reticulum
Hwang, C., Sinskey, A. J., & Lodish, H. F. (1992) · Science · doi:10.1126/science.1523409 · Cited by 1,968
Fluorescent indicators for cytosolic calcium based on rhodamine and fluorescein chromophores
Minta, A., Kao, J. P. Y., & Tsien, R. Y. (1989) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)83165-9 · Cited by 1,613
Fluorescent and colorimetric probes for detection of thiols
Chen, X., Zhou, Y., Peng, X., & Yoon, J. (2010) · Chemical Society Reviews · doi:10.1039/b925092a · Cited by 1,580
Niu, L.-Y., Guan, Y.-S., Chen, Y.-Z., Wu, L.-Z., Tung, C.-H., & Yang, Q.-Z. (2012) · Journal of the American Chemical Society · doi:10.1021/ja309079f · Cited by 901
Recent progress in fluorescent and colorimetric chemosensors for detection ofamino acids
Zhou, Y., & Yoon, J. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15159b · Cited by 760
Yang, X., Guo, Y., & Strongin, R. M. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201103759 · Cited by 658
Fluorescent probes for sensing and imaging
Ueno, T., & Nagano, T. (2011) · Nature Methods · doi:10.1038/nmeth.1663 · Cited by 633
Cited by
Coumarin-Based Small-Molecule Fluorescent Chemosensors
Cao, D., Liu, Z., Verwilst, P., Koo, S., Jangjili, P., Kim, J. S., & Lin, W. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00145 · Cited by 1,306
Applications of Supramolecular Anion Recognition
Busschaert, N., Caltagirone, C., Van Rossom, W., & Gale, P. A. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00099 · Cited by 1,249
Recent Development of Chemosensors Based on Cyanine Platforms
Sun, W., Guo, S., Hu, C., Fan, J., & Peng, X. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00001 · Cited by 1,109
Design strategies of fluorescent probes for selective detection among biothiols
Niu, L.-Y., Chen, Y.-Z., Zheng, H.-R., Wu, L.-Z., Tung, C.-H., & Yang, Q.-Z. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00152h · Cited by 870
Chemical Design and Synthesis of Functionalized Probes for Imaging and Treating Tumor Hypoxia
Liu, J.-N., Bu, W., & Shi, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00525 · Cited by 838
Self-citationDevelopment of Ion Chemosensors Based on Porphyrin Analogues
Ding, Y., Zhu, W.-H., & Xie, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00021 · Cited by 653
Dual-Site Fluorescent Probe for Visualizing the Metabolism of Cys in Living Cells
Yue, Y., Huo, F., Ning, P., Zhang, Y., Chao, J., Meng, X., & Yin, C. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.6b12845 · Cited by 499
Fluorescent Probes with Multiple Binding Sites for the Discrimination of Cys, Hcy, and GSH
Yin, C., Xiong, K., Huo, F., Salamanca, J. C., & Strongin, R. M. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201704084 · Cited by 493
Krämer, J., Kang, R., Grimm, L. M., De Cola, L., Picchetti, P., & Biedermann, F. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00746 · Cited by 449
Niu, H., Liu, J., O’Connor, H. M., Gunnlaugsson, T., James, T. D., & Zhang, H. (2023) · Chemical Society Reviews · doi:10.1039/d1cs01097b · Cited by 449
Self-citationFluorescent probes for the simultaneous detection of multiple analytes in biology
Kolanowski, J. L., Liu, F., & New, E. J. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00528h · Cited by 393
Multicomponent Platinum(II) Cages with Tunable Emission and Amino Acid Sensing
Zhang, M., Saha, M. L., Wang, M., Zhou, Z., Song, B., Lu, C., Yan, X., Li, X., Huang, F., Yin, S., et al. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.6b12536 · Cited by 361
Recent progress in the development of fluorescent probes for imaging pathological oxidative stress
Geng, Y., Wang, Z., Zhou, J., Zhu, M., Liu, J., & James, T. D. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00172a · Cited by 351
Self-citationYang, X.-F., Huang, Q., Zhong, Y., Li, Z., Li, H., Lowry, M., Escobedo, J. O., & Strongin, R. M. (2014) · Chemical Science · doi:10.1039/c4sc00308j · Cited by 343
Recent advances in multifunctional fluorescent probes for viscosity and analytes
Yang, X., Zhang, D., Ye, Y., & Zhao, Y. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214336 · Cited by 340
Functional synthetic probes for selective targeting and multi-analyte detection and imaging
Yue, Y., Huo, F., Cheng, F., Zhu, X., Mafireyi, T., Strongin, R. M., & Yin, C. (2019) · Chemical Society Reviews · doi:10.1039/c8cs01006d · Cited by 330
Sargazi, S., Fatima, I., Hassan Kiani, M., Mohammadzadeh, V., Arshad, R., Bilal, M., Rahdar, A., Díez-Pascual, A. M., & Behzadmehr, R. (2022) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2022.02.137 · Cited by 329
Yin, G., Niu, T., Gan, Y., Yu, T., Yin, P., Chen, H., Zhang, Y., Li, H., & Yao, S. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201800485 · Cited by 314
Sun, J., Cai, X., Wang, C., Du, K., Chen, W., Feng, F., & Wang, S. (2021) · Journal of the American Chemical Society · doi:10.1021/jacs.0c10517 · Cited by 279
Wang, F., Zhou, L., Zhao, C., Wang, R., Fei, Q., Luo, S., Guo, Z., Tian, H., & Zhu, W.-H. (2015) · Chemical Science · doi:10.1039/c5sc00216h · Cited by 275
He, L., Yang, X., Xu, K., Kong, X., & Lin, W. (2017) · Chemical Science · doi:10.1039/c7sc00423k · Cited by 254
Dong, B., Song, X., Wang, C., Kong, X., Tang, Y., & Lin, W. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b00422 · Cited by 253
A Substituted‐Rhodamine‐Based Reversible Fluorescent Probe for In Vivo Quantification of Glutathione
Li, N., Wang, T., Wang, N., Fan, M., & Cui, X. (2023) · Angewandte Chemie International Edition · doi:10.1002/anie.202217326 · Cited by 68
Pan, Y., Lei, S., Zhang, J., Qu, J., Huang, P., & Lin, J. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c04504 · Cited by 45
Metadata
- Authors
- Liu, J., Sun, Y.-Q., Huo, Y., Zhang, H., Wang, L., Zhang, P., Song, D., Shi, Y., & Guo, W.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-12-30
- Volume
- 136
- Issue
- 2
- Pages
- 574-577
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2324411030
- Cited by
- 588
- References
- 33
- FWCI
- 20.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.