The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Employing an ICT-FRET Integration Platform for the Real-Time Tracking of SO2 Metabolism in Cancer Cells and Tumor Models
Abstract
Glutathione (GSH) mediates a wide variety of biological events and human diseases. Although it has been the subject of intense study in recent years, a further understanding of its molecular mechanisms and metabolism routes in living cells has remained limited due to a lack of appropriate analytical tools. Sulfur dioxide (SO 2 ), an important metabolite of GSH, is usually associated with the symptoms of neurological disorders, cardiovascular diseases, and lung cancer. Herein, a novel multisignal fluorescent probe was rationally designed and exploited for the simultaneous detection of GSH and its metabolite SO 2 via an ICT-FRET synergetic mechanism. The probe shows completely reversed fluorescence responses toward GSH (enhanced red emission) and SO 2 (annihilated red fluorescence) with high selectivity and sensitivity. In particular, the probe displayed completely different fluorescent signals (blue-shift) with SO 2 in the presence of GSH, thereby allowing the imaging of the metabolism process of GSH to SO 2 in two independent channels without spectral cross interference. Given these advantages, this probe has been successfully applied to the real-time monitoring of the SO 2 metabolic process in living cells and mice models, and it has thus been found that GSH can metabolize SO 2 by enzymatic reaction with TST (thiosulfate sulphurtransferase); additionally, SO 2 was transformed into sulfate under SUOX (sulfite oxidase). We anticipate that this research will provide a convenient and efficient tool for understanding the interrelated physiological functions of GSH and SO 2 in more biosystems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oxidants, oxidative stress and the biology of ageing
Finkel, T., & Holbrook, N. J. (2000) · Nature · doi:10.1038/35041687 · Cited by 9,413
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Hussain, S. P., Hofseth, L. J., & Harris, C. C. (2003) · Nature Reviews Cancer · doi:10.1038/nrc1046 · Cited by 1,690
Sapsford, K. E., Berti, L., & Medintz, I. L. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200503873 · Cited by 1,561
Cell-signalling dynamics in time and space
Kholodenko, B. N. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1838 · Cited by 1,347
Lin, V. S., Chen, W., Xian, M., & Chang, C. J. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00298a · Cited by 1,037
FRET-Based Small-Molecule Fluorescent Probes: Rational Design and Bioimaging Applications
Yuan, L., Lin, W., Zheng, K., & Zhu, S. (2013) · Accounts of Chemical Research · doi:10.1021/ar300273v · Cited by 1,021
Recent progresses in small-molecule enzymatic fluorescent probes for cancer imaging
Liu, H.-W., Chen, L., Xu, C., Li, Z., Zhang, H., Zhang, X.-B., & Tan, W. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00862g · Cited by 948
Niu, L.-Y., Guan, Y.-S., Chen, Y.-Z., Wu, L.-Z., Tung, C.-H., & Yang, Q.-Z. (2012) · Journal of the American Chemical Society · doi:10.1021/ja309079f · Cited by 901
Real-time imaging of the intracellular glutathione redox potential
Gutscher, M., Pauleau, A.-L., Marty, L., Brach, T., Wabnitz, G. H., Samstag, Y., Meyer, A. J., & Dick, T. P. (2008) · Nature Methods · doi:10.1038/nmeth.1212 · Cited by 894
Yin, J., Kwon, Y., Kim, D., Lee, D., Kim, G., Hu, Y., Ryu, J.-H., & Yoon, J. (2014) · Journal of the American Chemical Society · doi:10.1021/ja412628z · Cited by 599
Umezawa, K., Yoshida, M., Kamiya, M., Yamasoba, T., & Urano, Y. (2017) · Nature Chemistry · doi:10.1038/nchem.2648 · Cited by 508
Dual-Site Fluorescent Probe for Visualizing the Metabolism of Cys in Living Cells
Yue, Y., Huo, F., Ning, P., Zhang, Y., Chao, J., Meng, X., & Yin, C. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.6b12845 · Cited by 499
Self-citationFluorescent Probes with Multiple Binding Sites for the Discrimination of Cys, Hcy, and GSH
Yin, C., Xiong, K., Huo, F., Salamanca, J. C., & Strongin, R. M. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201704084 · Cited by 493
Self-citationMolecular Basis of Sulfite Oxidase Deficiency from the Structure of Sulfite Oxidase
Kisker, C., Schindelin, H., Pacheco, A., Wehbi, W. A., Garrett, R. M., Rajagopalan, K. V., Enemark, J. H., & Rees, D. C. (1997) · Cell · doi:10.1016/s0092-8674(00)80488-2 · Cited by 484
Lim, S.-Y., Hong, K.-H., Kim, D. I., Kwon, H., & Kim, H.-J. (2014) · Journal of the American Chemical Society · doi:10.1021/ja500962u · Cited by 461
Ratiometric Detection of Mitochondrial Thiols with a Two-Photon Fluorescent Probe
Lim, C. S., Masanta, G., Kim, H. J., Han, J. H., Kim, H. M., & Cho, B. R. (2011) · Journal of the American Chemical Society · doi:10.1021/ja205081s · Cited by 365
A Reversible Fluorescent Probe for Real‐Time Quantitative Monitoring of Cellular Glutathione
Liu, Z., Zhou, X., Miao, Y., Hu, Y., Kwon, N., Wu, X., & Yoon, J. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201702114 · Cited by 312
Cheng, D., Peng, J., Lv, Y., Su, D., Liu, D., Chen, M., Yuan, L., & Zhang, X. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b01374 · Cited by 308
Quantitative real-time imaging of glutathione
Jiang, X., Chen, J., Bajić, A., Zhang, C., Song, X., Carroll, S. L., Cai, Z.-L., Tang, M., Xue, M., Cheng, N., et al. (2017) · Nature Communications · doi:10.1038/ncomms16087 · Cited by 268
Liu, C., Chen, W., Shi, W., Peng, B., Zhao, Y., Ma, H., & Xian, M. (2014) · Journal of the American Chemical Society · doi:10.1021/ja502968x · Cited by 235
Combinatorial Rosamine Library and Application to in Vivo Glutathione Probe
Ahn, Y.-H., Lee, J.-S., & Chang, Y.-T. (2007) · Journal of the American Chemical Society · doi:10.1021/ja068230m · Cited by 216
Sulfite Oxidase Deficiency in Man: Demonstration of the Enzymatic Defect
Mudd, S. H., Irreverre, F., & Laster, L. (1967) · Science · doi:10.1126/science.156.3782.1599 · Cited by 209
Chen, Z., Mu, X., Han, Z., Yang, S., Zhang, C., Guo, Z., Bai, Y., & He, W. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b09181 · Cited by 203
“Dual-Key-and-Lock” Ruthenium Complex Probe for Lysosomal Formaldehyde in Cancer Cells and Tumors
Liu, C., Zhang, R., Zhang, W., Liu, J., Wang, Y.-L., Du, Z., Song, B., Xu, Z. P., & Yuan, J. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.8b13898 · Cited by 190
Self-citationJiang, X., Yu, Y., Chen, J., Zhao, M., Chen, H., Song, X., Matzuk, A. J., Carroll, S. L., Tan, X., Sizovs, A., et al. (2015) · ACS Chemical Biology · doi:10.1021/cb500986w · Cited by 187
Combinatorial rosamine library and application to in vivo glutathione probe
이준석, 장영태, & 안영훈 (2007) · Cited by 187
Remote light-controlled intracellular target recognition by photochromic fluorescent glycoprobes
Zhang, J., Fu, Y., Han, H.-H., Zang, Y., Li, J., He, X.-P., Feringa, B. L., & Tian, H. (2017) · Nature Communications · doi:10.1038/s41467-017-01137-8 · Cited by 185
Ning, J., Liu, T., Dong, P., Wang, W., Ge, G., Wang, B., Yu, Z., Shi, L., Tian, X., Huo, X., et al. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.8b12136 · Cited by 167
Reversible Ratiometric Fluorescent Probe for Sensing Bisulfate/H2O2 and Its Application in Zebrafish
Zhang, W., Liu, T., Huo, F., Ning, P., Meng, X., & Yin, C. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01580 · Cited by 163
Self-citationJeong, E. M., Yoon, J., Lim, J., Shin, J., Cho, A. Y., Heo, J., Lee, K. B., Lee, J.-H., Lee, W. J., Kim, H.-J., et al. (2018) · Stem Cell Reports · doi:10.1016/j.stemcr.2017.12.007 · Cited by 134
Ye, Z., Yu, H., Yang, W., Zheng, Y., Li, N., Bian, H., Wang, Z., Liu, Q., Song, Y., Zhang, M., et al. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.8b11369 · Cited by 134
Zhang, W., Huo, F., & Yin, C. (2019) · Organic Letters · doi:10.1021/acs.orglett.9b01879 · Cited by 129
Self-citationLi, G., Chen, Y., Wang, J., Lin, Q. R., Zhao, J., Ji, L., & Chao, H. (2013) · Chemical Science · doi:10.1039/c3sc52301b · Cited by 122
Liu, Y., Li, K., Xie, K.-X., Li, L.-L., Yu, K., Wang, X., & Yu, X. (2016) · Chemical Communications · doi:10.1039/c5cc10505f · Cited by 121
Wang, L., Zhang, J., Kim, B., Peng, J., Berry, S. N., Ni, Y. Z., Su, D., Lee, J. Y., Yuan, L., & Chang, Y. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b05810 · Cited by 105
Kannan, N., Nguyen, L. V., Makarem, M., Dong, Y., Shih, K., Eirew, P. D., Raouf, A., Emerman, J. T., & Eaves, C. J. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403813111 · Cited by 99
Feng, G., Luo, X., Xu, L., Xie, S., Deng, L., Kang, W., He, F., Zhang, J., Lei, C., Lin, B., et al. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201901320 · Cited by 96
Ma, Y., Gao, W., Zhu, L., Zhao, Y., & Lin, W. (2019) · Chemical Communications · doi:10.1039/c9cc04411f · Cited by 55
A Coumarin-based Fluorescence Sensor for the Reversible Detection of Thiols
Cho, A. Y. H., & Choi, K. (2012) · Chemistry Letters · doi:10.1246/cl.2012.1611 · Cited by 40
A highly sensitive, cell-membrane-permeable fluorescent probe for glutathione
Yoshida, M., Kamiya, M., Yamasoba, T., & Urano, Y. (2014) · Bioorganic & Medicinal Chemistry Letters · doi:10.1016/j.bmcl.2014.08.033 · Cited by 26
Cited by
Near infrared fluorescent probes for detecting and imaging active small molecules
Ding, C., & Ren, T. (2023) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2023.215080 · Cited by 247
Qin, Z., Ren, T., Zhou, H., Zhang, X., He, L., Li, Z., Zhang, X., & Yuan, L. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202201541 · Cited by 140
Metadata
- Authors
- Zhang, W., Huo, F., Cheng, F., & Yin, C.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-03-04
- Volume
- 142
- Issue
- 13
- Pages
- 6324-6331
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W3009599107
- Cited by
- 267
- References
- 41
- FWCI
- 14.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.