The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Nanoscale Metal–Organic Frameworks for Ratiometric Oxygen Sensing in Live Cells
Open accessAbstract
We report the design of a phosphorescence/fluorescence dual-emissive nanoscale metal-organic framework (NMOF), R-UiO, as an intracellular oxygen (O2) sensor. R-UiO contains a Pt(II)-porphyrin ligand as an O2-sensitive probe and a Rhodamine-B isothiocyanate ligand as an O2-insensitive reference probe. It exhibits good crystallinity, high stability, and excellent ratiometric luminescence response to O2 partial pressure. In vitro experiments confirmed the applicability of R-UiO as an intracellular O2 biosensor. This work is the first report of a NMOF-based intracellular oxygen sensor and should inspire the design of ratiometric NMOF sensors for other important analytes in biological systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metal–Organic Framework Materials as Chemical Sensors
Kreno, L. E., Leong, K., Farha, O. K., Allendorf, M., Van Duyne, R. P., & Hupp, J. T. (2012) · Chemical Reviews · doi:10.1021/cr200324t · Cited by 7,136
Hypoxia — a key regulatory factor in tumour growth
Harris, A. L. (2002) · Nature Reviews Cancer · doi:10.1038/nrc704 · Cited by 5,177
Luminescent metal–organic frameworks for chemical sensing and explosive detection
Hu, Z., Deibert, B. J., & Li, J. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00010b · Cited by 4,169
Molecular Fluorescence: Principles and Applications
Valeur, B., & Berberan‐Santos, M. N. (2012) · Wiley eBooks · doi:10.1002/9783527650002 · Cited by 4,098
Höckel, M., Schlenger, K., Aral, B., Mitze, M., Schäffer, U., & Vaupel, P. W. (1996) · PubMed · Cited by 1,727
BioMOFs: Metal–Organic Frameworks for Biological and Medical Applications
McKinlay, A. C., Morris, R. E., Horcajada, P., Férey, G., Gref, R., Couvreur, P., & Serre, C. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.201000048 · Cited by 1,256
Why is the partial oxygen pressure of human tissues a crucial parameter? Small molecules and hypoxia
Carreau, A., Hafny‐Rahbi, B. E., Matejuk, A., Grillon, C., & Kieda, C. (2011) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2011.01258.x · Cited by 1,246
Direct measurement of local oxygen concentration in the bone marrow of live animals
Spencer, J. A., Ferraro, F., Roussakis, E., Klein, A., Wu, J., Runnels, J. M., Zaher, W., Mortensen, L. J., Alt, C., Turcotte, R., et al. (2014) · Nature · doi:10.1038/nature13034 · Cited by 1,167
A dual-emissive-materials design concept enables tumour hypoxia imaging
Zhang, G., Palmer, G. M., Dewhirst, M. W., & Fraser, C. L. (2009) · Nature Materials · doi:10.1038/nmat2509 · Cited by 1,150
Gatenby, R. A., Kessler, H. B., Rosenblum, J. S., Coia, L. R., Moldofsky, P. J., Hartz, W. H., & Broder, G. J. (1988) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(88)90002-8 · Cited by 798
Lu, K., He, C., & Lin, W. (2014) · Journal of the American Chemical Society · doi:10.1021/ja508679h · Cited by 745
Self-citationModern Molecular Photochemistry of Organic Molecules
Turro, N. J., Ramamurthy, V., & Scaiano, J. C. (2012) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.2012.01178.x · Cited by 686
Manganese-Based Nanoscale Metal−Organic Frameworks for Magnetic Resonance Imaging
Taylor, K. M. L., Rieter, W. J., & Lin, W. (2008) · Journal of the American Chemical Society · doi:10.1021/ja803777x · Cited by 657
Self-citationZhang, G., Chen, J., Payne, S. J., Kooi, S. E., Demas, J. N., & Fraser, C. L. (2007) · Journal of the American Chemical Society · doi:10.1021/ja0720255 · Cited by 620
Metal–Organic Frameworks as Sensory Materials and Imaging Agents
Liu, D., Lu, K., Poon, C., & Lin, W. (2014) · Inorganic Chemistry · doi:10.1021/ic402194c · Cited by 386
Self-citationRatiometric Single‐Nanoparticle Oxygen Sensors for Biological Imaging
Wu, C., Bull, B., Christensen, K., & McNeill, J. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200805894 · Cited by 378
Imaging oxygenation of human tumours
Padhani, A. R., Krohn, K. A., Lewis, J. S., & Alber, M. (2007) · European Radiology · doi:10.1007/s00330-006-0431-y · Cited by 328
Koo, Y.-E. L., Cao, Y., Kopelman, R., Koo, S. M., Brasuel, M., & Philbert, M. A. (2004) · Analytical Chemistry · doi:10.1021/ac035493f · Cited by 316
Dual emission laser induced fluorescence for direct planar scalar behavior measurements
Coppeta, J. R., & Rogers, C. (1998) · Experiments in Fluids · doi:10.1007/s003480050202 · Cited by 295
Nanoscale Metal–Organic Frameworks for Real-Time Intracellular pH Sensing in Live Cells
He, C., Lu, K., & Lin, W. (2014) · Journal of the American Chemical Society · doi:10.1021/ja507333c · Cited by 294
Self-citationLanthanide near infrared imaging in living cells with Yb 3+ nano metal organic frameworks
Foucault-Collet, A., Gogick, K. A., White, K. A., Villette, S., Pallier, A., Collet, G., Kieda, C., Li, T., Geib, S. J., Rosi, N. L., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1305910110 · Cited by 289
Manna, K., Zhang, T., Greene, F. X., & Lin, W. (2015) · Journal of the American Chemical Society · doi:10.1021/ja512478y · Cited by 289
Self-citationIodinated Nanoscale Coordination Polymers as Potential Contrast Agents for Computed Tomography
deKrafft, K. E., Xie, Z., Cao, G., Tran, S., Ma, L., Zhou, O. Z., & Lin, W. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200904958 · Cited by 249
Self-citationOxygen Microscopy by Two‐Photon‐Excited Phosphorescence
Finikova, O. S., Lebedev, A. Y., Aprelev, A., Troxler, T., Gao, F., Garnacho, C., Muro, S., Hochstrasser, R. M., & Vinogradov, S. A. (2008) · ChemPhysChem · doi:10.1002/cphc.200800296 · Cited by 240
Ratiometric optical oxygen sensing: a review in respect of material design
Feng, Y., Cheng, J., Zhou, L., Zhou, X., & Xiang, H. (2012) · The Analyst · doi:10.1039/c2an35907c · Cited by 233
Wang, X.-D., Stolwijk, J. A., Lang, T., Sperber, M., Meier, R. J., Wegener, J., & Wolfbeis, O. S. (2012) · Journal of the American Chemical Society · doi:10.1021/ja308830e · Cited by 223
Ratiometric Molecular Sensor for Monitoring Oxygen Levels in Living Cells
Yoshihara, T., Yamaguchi, Y., Hosaka, M., Takeuchi, T., & Tobita, S. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201107557 · Cited by 222
Wu, P., Wang, J., He, C., Zhang, X., Wang, Y., Liu, T., & Duan, C. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201102157 · Cited by 221
Self-citationFluorescent/phosphorescent dual-emissive conjugated polymer dots for hypoxia bioimaging
Zhao, Q., Zhou, X., Cao, T., Zhang, K. Y., Yang, L., Liu, S., Liang, H., Yang, H., Li, F., & Huang, W. (2015) · Chemical Science · doi:10.1039/c4sc03062a · Cited by 219
Cooper, R. A., Carrington, B. M., Loncaster, J. A., Todd, S. M., Davidson, S. E., Logue, J. P., Luthra, A. D., Jones, A. P., Stratford, I., Hunter, R. D., et al. (2000) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(00)00259-0 · Cited by 210
Molecular imaging of hypoxia with radiolabelled agents
Mees, G., Dierckx, R., Vangestel, C., & Van de Wiele, C. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1195-9 · Cited by 201
Hatakeyama, W., Sanchez, T. J., Rowe, M. D., Serkova, N. J., Liberatore, M. W., & Boyes, S. G. (2011) · ACS Applied Materials & Interfaces · doi:10.1021/am200075q · Cited by 128
Cellular response to tissue hypoxia and its involvement in disease progression
Ikeda, E. (2005) · Pathology International · doi:10.1111/j.1440-1827.2005.01877.x · Cited by 83
A ratiometric luminescent oxygen sensor based on a chemically functionalized quantum dot
Amelia, M., Lavie-Cambot, A., McClenaghan, N. D., & Credi, A. (2010) · Chemical Communications · doi:10.1039/c0cc02163f · Cited by 77
Suresh, V. M., Chatterjee, S., Modak, R., Tiwari, V., Patel, A. B., Kundu, T. K., & Maji, T. K. (2014) · The Journal of Physical Chemistry C · doi:10.1021/jp501030h · Cited by 40
Hoogsteen, I. J., Lok, J., Marres, H. A. M., Takes, R. P., Rijken, P. F. J. W., van der Kogel, A. J., & Kaanders, J. H. A. M. (2009) · European Journal of Cancer · doi:10.1016/j.ejca.2009.07.012 · Cited by 38
Cited by
Emerging Multifunctional Metal–Organic Framework Materials
Li, B., Wen, H., Cui, Y., Zhou, W., Qian, G., & Chen, B. (2016) · Advanced Materials · doi:10.1002/adma.201601133 · Cited by 1,587
Two-dimensional metal–organic framework nanosheets: synthesis and applications
Zhao, M., Huang, Y., Peng, Y., Huang, Z., Ma, Q., & Zhang, H. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00268a · Cited by 1,348
Luminescent sensors based on metal-organic frameworks
Zhang, Y., Yuan, S., Day, G., Wang, X., Yang, X., & Zhou, H.-C. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.06.007 · Cited by 1,255
Porous metal-organic frameworks for gas storage and separation: Status and challenges
Li, H., Li, L., Lin, R.-B., Zhou, W., Zhang, Z., Xiang, S., & Chen, B. (2019) · EnergyChem · doi:10.1016/j.enchem.2019.100006 · Cited by 891
Ratiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 820
Metadata
- Authors
- Xu, R., Wang, Y., Duan, X., Lu, K., Micheroni, D., Hu, A., & Lin, W.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-02-16
- Volume
- 138
- Issue
- 7
- Pages
- 2158-2161
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2278059930
- Cited by
- 319
- References
- 36
- FWCI
- 18.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.