Competitive Immunoassays for the Detection of Small Molecules Using Single Molecule Arrays
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Small-molecule detection is important for many applications including clinical diagnostics, drug discovery, and measurements of environmental samples and agricultural products. Current techniques for small-molecule detection suffer from various limitations including low analytical sensitivity and complex sample processing. Furthermore, as a result of their small size, small molecules are difficult to detect using an antibody pair in a traditional sandwich assay format. To overcome these limitations, we developed an ultrasensitive competitive immunoassay for small-molecule detection using Single Molecule Arrays (Simoa). We show that the competitive Simoa assay is approximately 50-fold more sensitive than the conventional ELISA. We performed theoretical calculations to determine the factors that influence the sensitivity of competitive Simoa assays and used them to achieve maximal sensitivity. We also demonstrate detection of small molecules in complex biological samples. We show that the competitive Simoa assay is a simple, fast, and highly sensitive approach for ultrasensitive detection of small molecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119
Self-citationBöttcher, J. P., Bonavita, E., Chakravarty, P., Blees, H., Cabeza-Cabrerizo, M., Sammicheli, S., Rogers, N. C., Sahai, E., Zelenay, S., & Reis e Sousa, C. (2018) · Cell · doi:10.1016/j.cell.2018.01.004 · Cited by 1,857
Serum cortisol: an up-to-date assessment of routine assay performance
Hawley, J. M., Owen, L. J., Lockhart, S. J., Monaghan, P. J., Armston, A., Chadwick, C. A., Wilshaw, H., Freire, M., Perry, L., & Keevil, B. G. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2016.255034 · Cited by 95
Cited by
Investigation of Cortisol Dynamics in Human Sweat Using a Graphene-Based Wireless mHealth System
Torrente-Rodríguez, R. M., Tu, J., Yang, Y., Min, J., Wang, M., Song, Y., Yu, Y., Xu, C., Ye, C., IsHak, W. W., et al. (2020) · Matter · doi:10.1016/j.matt.2020.01.021 · Cited by 479
“The large surface area and fast electron mobility of graphene offers superior performance in electrochemical sensing (Figure 1G),(33) while competitive immunosensing strategies offer major advances in highly selective small hormone molecule detection.(34)”
BackgroundSabaté del Río, J., Henry, O. Y. F., Jolly, P., & Ingber, D. E. (2019) · Nature Nanotechnology · doi:10.1038/s41565-019-0566-z · Cited by 450
Boruah, P. K., & Das, M. R. (2020) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2019.121516 · Cited by 237
Nanozyme-based electrochemical biosensors for disease biomarker detection
Mahmudunnabi, R. G., Farhana, F. Z., Kashaninejad, N., Firoz, S. H., Shim, Y.-B., & Shiddiky, M. J. A. (2020) · The Analyst · doi:10.1039/d0an00558d · Cited by 219
FRET Based Biosensor: Principle Applications Recent Advances and Challenges
Verma, A. K., Noumani, A., Yadav, A. K., & Solanki, P. R. (2023) · Diagnostics · doi:10.3390/diagnostics13081375 · Cited by 202
Metadata
- Authors
- Wang, X., Cohen, L., Wang, J., & Walt, D. R.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-11-29
- Volume
- 140
- Issue
- 51
- Pages
- 18132-18139
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2903029096
- Cited by
- 156
- References
- 3
- FWCI
- 3.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.