The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
De Novo Design of Chemical Stability Near-Infrared Molecular Probes for High-Fidelity Hepatotoxicity Evaluation In Vivo
Abstract
Near-infrared (NIR) fluorescence imaging technique is garnering increasing research attention due to various advantages. However, most NIR fluorescent probes still suffer from a false signals problem owing to their instability in real application. Especially in a pathological environment, many NIR probes can be easily destroyed due to the excessive generation of highly reactive species and causing a distorted false signal. Herein, we proposed an approach for developing a new stable NIR dye platform with an optically tunable group to eliminate false signals using the combination of dyes screening and rational design strategy. The conception is validated by the construction of two high-fidelity NIR fluorescent probes ( NIR-LAP and NIR-ONOO – ) sensing leucine aminopeptidase (LAP) and peroxynitrite (ONOO – ), the markers of hepatotoxicity. These probes ( NIR-LAP and NIR-ONOO – ) were demonstrated to sensitively and accurately monitor LAP and ONOO – (detection limit: 80 mU/L for LAP and 90 nM for ONOO – ), thereby allowing one to precisely evaluate drug-induced hepatotoxicity. In addition, based on the fluctuation of LAP, the therapeutic efficacy of six hepatoprotective medicines for acetaminophen-induced hepatotoxicity was analyzed in vivo. We anticipate the high-fidelity NIR dye platform with an optically tunable group could provide a convenient and efficient tool for the development of future probes applied in the pathological environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitric Oxide and Peroxynitrite in Health and Disease
Pacher, P., Beckman, J. S., & Liaudet, L. (2007) · Physiological Reviews · doi:10.1152/physrev.00029.2006 · Cited by 6,390
Peroxynitrite: biochemistry, pathophysiology and development of therapeutics
Szabó, C., Ischiropoulos, H., & Radi, R. (2007) · Nature Reviews Drug Discovery · doi:10.1038/nrd2222 · Cited by 2,134
Yuan, L., Lin, W., Zheng, K., He, L., & Huang, W. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35313j · Cited by 1,822
Self-citationRecent progress in the development of near-infrared fluorescent probes for bioimaging applications
Guo, Z., Park, S., Yoon, J., & Shin, I. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60271k · Cited by 1,801
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Recent progresses in small-molecule enzymatic fluorescent probes for cancer imaging
Liu, H.-W., Chen, L., Xu, C., Li, Z., Zhang, H., Zhang, X.-B., & Tan, W. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00862g · Cited by 948
Self-citationCase definition and phenotype standardization in drug-induced liver injury
Aithal, G. P., Watkins, P. B., Andrade, R. J., Larrey, D., Molokhia, M., Takikawa, H., Hunt, C. M., Wilke, R. A., Avigan, M., Kaplowitz, N., et al. (2011) · Clinical Pharmacology & Therapeutics · doi:10.1038/clpt.2011.58 · Cited by 944
ACG Clinical Guideline: the diagnosis and management of idiosyncratic drug-induced liver injury
Chalasani, N. P., Hayashi, P. H., Bonkovsky, H. L., Navarro, V. J., Lee, W. M., & Fontana, R. J. (2014) · American Journal of Gastroenterology · doi:10.1038/ajg.2014.131 · Cited by 860
NIR dyes for bioimaging applications
Escobedo, J. O., Rusin, O., Lim, S., & Strongin, R. M. (2010) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2009.10.022 · Cited by 762
A Unique Approach to Development of Near-Infrared Fluorescent Sensors for in Vivo Imaging
Yuan, L., Lin, W., Zhao, S., Gao, W., Chen, B., He, L., & Zhu, S. (2012) · Journal of the American Chemical Society · doi:10.1021/ja305802v · Cited by 679
Self-citationShuhendler, A. J., Pu, K., Cui, L., Uetrecht, J. P., & Rao, J. (2014) · Nature Biotechnology · doi:10.1038/nbt.2838 · Cited by 623
Yu, F., Li, P., Wang, B., & Han, K. (2013) · Journal of the American Chemical Society · doi:10.1021/ja401360a · Cited by 621
Fluorogenic probes for disease-relevant enzymes
Zhang, J., Chai, X., He, X.-P., Kim, H.-J., Yoon, J., & Tian, H. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00907k · Cited by 606
Yu, F., Li, P., Li, G., Zhao, G., Chu, T., & Han, K. (2011) · Journal of the American Chemical Society · doi:10.1021/ja202582x · Cited by 578
Yuan, L., Lin, W., Yang, Y., & Chen, H. (2012) · Journal of the American Chemical Society · doi:10.1021/ja209292b · Cited by 562
Self-citationCheng, D., Pan, Y., Wang, L., Zeng, Z., Yuan, L., Zhang, X., & Chang, Y.-T. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.6b10508 · Cited by 500
Self-citationRedox-Responsive Fluorescent Probes with Different Design Strategies
Lou, Z., Li, P., & Han, K. (2015) · Accounts of Chemical Research · doi:10.1021/acs.accounts.5b00009 · Cited by 497
Acetaminophen (APAP) hepatotoxicity—Isn’t it time for APAP to go away?
Lee, W. M. (2017) · Journal of Hepatology · doi:10.1016/j.jhep.2017.07.005 · Cited by 442
Cover, C., Mansouri, A., Knight, T. R., Bajt, M. L., Lemasters, J. J., Pessayre, D., & Jaeschke, H. (2005) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1124/jpet.105.088898 · Cited by 373
Karton-Lifshin, N., Segal, E., Omer, L., Portnoy, M., Satchi-Fainaro, R., & Shabat, D. (2011) · Journal of the American Chemical Society · doi:10.1021/ja203145v · Cited by 366
Oushiki, D., Kojima, H., Terai, T., Arita, M., Hanaoka, K., Urano, Y., & Nagano, T. (2010) · Journal of the American Chemical Society · doi:10.1021/ja910090v · Cited by 361
Mechanisms of drug-induced liver injury
Yuan, L., & Kaplowitz, N. (2013) · Clinics in Liver Disease · doi:10.1016/j.cld.2013.07.002 · Cited by 322
Self-citationMitochondrial-targeted fluorescent probes for reactive oxygen species
Dickinson, B. C., Srikun, D., & Chang, C. J. (2010) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2009.10.014 · Cited by 314
Knight, T. R. (2001) · Toxicological Sciences · doi:10.1093/toxsci/62.2.212 · Cited by 313
Fluorescent probes for the selective detection of chemical species inside mitochondria
Xu, Z., & Xu, L. (2016) · Chemical Communications · doi:10.1039/c5cc09248e · Cited by 291
Molecular Imaging of Peroxynitrite with HKGreen-4 in Live Cells and Tissues
Peng, T., Wong, N.-K., Chen, X., Chan, Y.-K., Ho, D. H.-H., Sun, Z., Hu, J. J., Shen, J., El-Nezami, H., & Yang, D. (2014) · Journal of the American Chemical Society · doi:10.1021/ja504624q · Cited by 273
Xu, W., Teoh, C. L., Peng, J., Su, D., Yuan, L., & Chang, Y.-T. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.03.038 · Cited by 252
Self-citationSun, X., Xu, Q., Kim, G., Flower, S. E., Lowe, J. P., Yoon, J., Fossey, J. S., Qian, X., Bull, S. D., & James, T. D. (2014) · Chemical Science · doi:10.1039/c4sc01417k · Cited by 218
Peng, J., Samanta, A., Zeng, X., Han, S., Wang, L., Su, D., Loong, D. T. B., Kang, N., Park, S., All, A. H., et al. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201612020 · Cited by 216
Self-citationLi, X., Tao, R.-R., Hong, L.-J., Cheng, J., Jiang, Q., Lu, Y.-M., Liao, M.-H., Ye, W.-F., Lu, N.-N., Han, F., et al. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b06865 · Cited by 214
Li, Y., Xie, X., Yang, X., Li, M., Jiao, X., Sun, Y., Wang, X., & Tang, B. (2017) · Chemical Science · doi:10.1039/c7sc00303j · Cited by 197
Near‐Infrared Fluorescent Molecular Probe for Sensitive Imaging of Keloid
Miao, Q., Yeo, D. C., Wiraja, C., Zhang, J., Ning, X., Xu, C., & Pu, K. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201710727 · Cited by 187
Sulfone-Rhodamines: A New Class of Near-Infrared Fluorescent Dyes for Bioimaging
Liu, J., Sun, Y.-Q., Zhang, H., Shi, H., Shi, Y., & Guo, W. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b08338 · Cited by 185
Li, H., Li, X., Wu, X., Shi, W., & Ma, H. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00503 · Cited by 181
Cheng, D., Xu, W., Yuan, L., & Zhang, X. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01671 · Cited by 177
Self-citationZhou, X., Kwon, Y., Kim, G., Ryu, J.-H., & Yoon, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.08.089 · Cited by 163
Apocynin inhibits peroxynitrite formation by murine macrophages
Muijsers, R. B. R., Van Den Worm, E., Folkerts, G., Beukelman, C. J., Koster, A. S., Postma, D. S., & Nijkamp, F. P. (2000) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0703401 · Cited by 160
Peng, T., Chen, X., Gao, L., Zhang, T., Wang, W., Shen, J., & Yang, D. (2016) · Chemical Science · doi:10.1039/c6sc00012f · Cited by 158
He, X., Li, L., Yu, F., Shi, W. S., Li, X., & Ma, H. (2017) · Chemical Science · doi:10.1039/c6sc05712h · Cited by 157
HKGreen-3: A Rhodol-Based Fluorescent Probe for Peroxynitrite
Tao, P., & Yang, D. (2010) · Organic Letters · doi:10.1021/ol102182j · Cited by 152
Mitochondrial Involvement in Drug-Induced Liver Injury
Pessayre, D., Mansouri, A., Berson, A., & Fromenty, B. (2009) · Handbook of experimental pharmacology · doi:10.1007/978-3-642-00663-0_11 · Cited by 143
Signal Transduction Pathways Involved in Drug-Induced Liver Injury
Han, D., Shinohara, M., Ybanez, M. D., Saberi, B., & Kaplowitz, N. (2009) · Handbook of experimental pharmacology · doi:10.1007/978-3-642-00663-0_10 · Cited by 119
Xu, K., Chen, H., Tian, J., Ding, B., Xie, Y., Qiang, M., & Tang, B. (2011) · Chemical Communications · doi:10.1039/c1cc12994e · Cited by 117
Li, H., Li, X., Shi, W. S., Xu, Y., & Ma, H. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201808400 · Cited by 111
Wang, L., Zhang, J., Kim, B., Peng, J., Berry, S. N., Ni, Y. Z., Su, D., Lee, J. Y., Yuan, L., & Chang, Y. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b05810 · Cited by 105
Self-citationGong, Q., Shi, W. S., Li, L., & Ma, H. (2015) · Chemical Science · doi:10.1039/c5sc03600c · Cited by 99
Zhou, Z., Wang, F., Yang, G., Lu, C., Nie, J., Chen, Z., Ren, J., Sun, Q., Zhao, C., & Zhu, W. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02910 · Cited by 99
Zhang, W., Liu, F., Zhang, C., Luo, J., Luo, J., Yu, W., & Kong, L. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03332 · Cited by 99
Biomarkers for drug-induced liver injury
Shi, Q., Hong, H., Senior, J. R., & Tong, W. (2010) · Expert Review of Gastroenterology & Hepatology · doi:10.1586/egh.10.8 · Cited by 91
Sun, Q., Yang, S.-H., Wu, L., Dong, Q., Yang, W., & Yang, G. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b01545 · Cited by 84
Amacher, D. E., Schomaker, S., & Aubrecht, J. (2013) · Molecular Diagnosis & Therapy · doi:10.1007/s40291-013-0049-0 · Cited by 55
Kondo, C., Shibata, K., Terauchi, M., Kajiyama, H., Ino, K., Nomura, S., Nawa, A., Mizutani, S., & Kikkawa, F. (2005) · International Journal of Cancer · doi:10.1002/ijc.21509 · Cited by 40
Chai, X., Xiao, J., Li, M., Wang, C., An, H., Li, C., Li, Y., Zhang, D., Cui, X., & Wang, T. (2018) · Chemistry - A European Journal · doi:10.1002/chem.201802875 · Cited by 38
Coşkun, B. D. Ö., Yücesoy, M., Gürsoy, Ş., Başkol, M., Yurçi, A., Yağbasan, A., Doğan, S., & Başkol, G. (2015) · European Journal of Gastroenterology & Hepatology · doi:10.1097/meg.0000000000000264 · Cited by 32
A General Strategy for Development of Near‐Infrared Fluorescent Probes for Bioimaging
Chen, W., Xu, S. J., Day, J. J., et al. (2017) · Angewandte Chemie · doi:10.1002/ange.201710688 · Cited by 32
The dual role of osteopontin in acetaminophen hepatotoxicity
He, C.-Y., Liang, B., Fan, X., Cao, L., Chen, R., Guo, Y., & Zhao, J. (2012) · Acta Pharmacologica Sinica · doi:10.1038/aps.2012.47 · Cited by 20
Cited by
J -Aggregates of Cyanine Dye for NIR-II in Vivo Dynamic Vascular Imaging beyond 1500 nm
Sun, C., Li, B., Zhao, M., Wang, S., Lei, Z., Lu, L., Zhang, H., Feng, L., Dou, C., Yin, D., et al. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b10043 · Cited by 582
Hemicyanine‐Based Near‐Infrared Activatable Probes for Imaging and Diagnosis of Diseases
Zeng, Z., Liew, S. S., Wei, X., & Pu, K. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202107877 · Cited by 359
Zeng, S., Liu, X., Kafuti, Y. S., Kim, H., Wang, J., Peng, X., Li, H., & Yoon, J. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00799a · Cited by 341
Ren, T., Wang, Z., Xiang, Z., Lu, P., Lai, H., Yuan, L., Zhang, X., & Tan, W. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202009986 · Cited by 273
Self-citationZhang, W., Huo, F., Cheng, F., & Yin, C. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c00992 · Cited by 267
Metadata
- Authors
- Cheng, D., Peng, J., Lv, Y., Su, D., Liu, D., Chen, M., Yuan, L., & Zhang, X.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-03-22
- Volume
- 141
- Issue
- 15
- Pages
- 6352-6361
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2925268815
- Cited by
- 308
- References
- 56
- FWCI
- 15.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.