The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Imaging the Thermodynamic State of Lipid Membranes with Multiplex CARS Microscopy
Abstract
Multiplex coherent anti-Stokes Raman scattering (CARS) microscopic imaging is demonstrated for the first time and used to visualize the thermodynamic state, either liquid crystalline or gel phase, of lipid membranes. Whereas in spontaneous Raman scattering the low scattering cross section is generally prohibitive for high-resolution microscopic imaging, the signal enhancement in multiplex CARS, by more than 4 orders of magnitude, enables microscopic imaging with realistic frame rates (∼min -1 ). Because of the broad spectral window over which the CARS signal is detected simultaneously, the identification of the thermodynamic state of the lipid membranes can be accomplished directly, without any additional tuning of the lasers. We demonstrate that the experimental CARS spectral data are highly consistent with those obtained with spontaneous Raman scattering, with a signal-to-noise ratio determined only by Poisson noise. In addition, the inherent intensity normalization renders multiplex CARS a robust imaging technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional rafts in cell membranes
Simons, K., & Ikonen, E. (1997) · Nature · doi:10.1038/42408 · Cited by 9,757
Cited by
Coherent Anti-Stokes Raman Scattering Microscopy: Instrumentation, Theory, and Applications
Cheng, J.-X., & Xie, X. S. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp035693v · Cited by 963
Vibrational spectroscopic imaging of living systems: An emerging platform for biology and medicine
Cheng, J.-X., & Xie, X. S. (2015) · Science · doi:10.1126/science.aaa8870 · Cited by 874
Raman Techniques: Fundamentals and Frontiers
Jones, R. R., Hooper, D. C., Zhang, L., Wolverson, D., & Valev, V. K. (2019) · Nanoscale Research Letters · doi:10.1186/s11671-019-3039-2 · Cited by 804
Chemically sensitive bioimaging with coherent Raman scattering
Camp Jr, C. H., & Cicerone, M. T. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.60 · Cited by 472
Raman spectroscopy: techniques and applications in the life sciences
Shipp, D. W., Sinjab, F., & Notingher, I. (2017) · Advances in Optics and Photonics · doi:10.1364/aop.9.000315 · Cited by 396
Spectral focusing: High spectral resolution spectroscopy with broad-bandwidth laser pulses
Hellerer, T., Enejder, A. M. K., & Zumbusch, A. (2004) · Applied Physics Letters · doi:10.1063/1.1768312 · Cited by 384
Imaging of EdU, an Alkyne-Tagged Cell Proliferation Probe, by Raman Microscopy
Yamakoshi, H., Dodo, K., Okada, M., Ando, J., Palonpon, A., Fujita, K., Kawata, S., & Sodeoka, M. (2011) · Journal of the American Chemical Society · doi:10.1021/ja108404p · Cited by 356
Stimulated Raman scattering microscopy: an emerging tool for drug discovery
Tipping, W. J., Lee, M., Serrels, A., Brunton, V. G., & Hulme, A. N. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00693g · Cited by 266
Metadata
- Authors
- Müller, M., & Schins, J. M.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-03-15
- Volume
- 106
- Issue
- 14
- Pages
- 3715-3723
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W2070115914
- Cited by
- 308
- References
- 1
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.