The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Generation of Solution and Surface Gradients Using Microfluidic Systems
Abstract
This paper describes a simple, versatile method of generating gradients in composition in solution or on surfaces using microfluidic systems. This method is based on controlled diffusive mixing of species in solutions that are flowing laminarly, at low Reynolds number, inside a network of microchannels. We demonstrate the use of this procedure to generate (1) gradients in the compositions of solutions, measured directly by colorimetric assays and (2) gradients in topography of the surfaces produced by generating concentration gradients of etching reagents, and then using these gradients to etch profiles into the substrate. The lateral dimensions of the gradients examined here, which went from 350 to 900 μm, are determined by the width of the microchannels. Gradients of different size, resolution, and shape have been generated using this method. The shape of the gradients can be changed continuously (dynamic gradients) by varying the relative flow velocities of the input streams of fluids. The method is experimentally simple and highly adaptable, and requires no special equipment except for an elastomeric relief structure that can be readily prepared by rapid prototyping. This technique provides a new platform with which to study phenomena that depend on gradients in concentration, especially dynamic phenomena in cell biology (chemotaxis and haptotaxis) and surface chemistry (nucleation and growth of crystals, etching, and Marangoni effects).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Park, G. S. (1975) · Polymer · doi:10.1016/0032-3861(75)90130-5 · Cited by 14,967
Notch Signaling: Cell Fate Control and Signal Integration in Development
Artavanis-Tsakonas, S., Rand, M. D., & Lake, R. J. (1999) · Science · doi:10.1126/science.284.5415.770 · Cited by 5,909
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Self-citationParent, C. A., & Devreotes, P. N. (1999) · Science · doi:10.1126/science.284.5415.765 · Cited by 890
Control of crystal nucleation by patterned self-assembled monolayers
Aizenberg, J., Black, A. J., & Whitesides, G. M. (1999) · Nature · doi:10.1038/19047 · Cited by 853
Self-citationAizenberg, J., Black, A. J., & Whitesides, G. M. (1999) · Journal of the American Chemical Society · doi:10.1021/ja984254k · Cited by 491
Self-citationComplete asymmetric induction of supramolecular chirality in a hydrogen-bonded assembly
Prins, L. J., Huskens, J., de Jong, F., Timmerman, P., & Reinhoudt, D. N. (1999) · Nature · doi:10.1038/19053 · Cited by 481
Spatial control of actin polymerization during neutrophil chemotaxis
Weiner, O. D., Servant, G., Welch, M. D., Mitchison, T. J., Sedat, J. W., & Bourne, H. R. (1999) · Nature Cell Biology · doi:10.1038/10042 · Cited by 284
Molecular Gradients of .omega.-Substituted Alkanethiols on Gold: Preparation and Characterization
Liedberg, B., & Tengvall, P. (1995) · Langmuir · doi:10.1021/la00010a037 · Cited by 173
Terrill, R. H., Balss, K. M., Zhang, Y., & Bohn, P. W. (2000) · Journal of the American Chemical Society · doi:10.1021/ja993442n · Cited by 130
Cited by
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Self-citationDirect Ink Writing of 3D Functional Materials
Lewis, J. A. (2006) · Advanced Functional Materials · doi:10.1002/adfm.200600434 · Cited by 1,740
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Self-citationMicrofabrication meets microbiology
Weibel, D. B., DiLuzio, W. R., & Whitesides, G. M. (2007) · Nature Reviews Microbiology · doi:10.1038/nrmicro1616 · Cited by 788
Self-citationChaotic mixing in three-dimensional microvascular networks fabricated by direct-write assembly
Therriault, D., White, S. R., & Lewis, J. A. (2003) · Nature Materials · doi:10.1038/nmat863 · Cited by 707
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Biomolecular gradients in cell culture systems
Keenan, T. M., & Folch, A. (2008) · Lab Chip · doi:10.1039/b711887b · Cited by 596
A trap-and-release integrated microfluidic system for dynamic microarray applications
Tan, W.-H., & Takeuchi, S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0606625104 · Cited by 591
Polymer Scaffolds for Biomaterials Applications
Shoichet, M. S. (2010) · Macromolecules · doi:10.1021/ma901530r · Cited by 468
Vascular Smooth Muscle Cell Durotaxis Depends on Substrate Stiffness Gradient Strength
Isenberg, B. C., DiMilla, P. A., Walker, M., Kim, S., & Wong, J. Y. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2009.06.021 · Cited by 403
Gradient biomaterials for soft-to-hard interface tissue engineering
Seidi, A., Ramalingam, M., Elloumi-Hannachi, I., Ostrovidov, S., & Khademhosseini, A. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.01.011 · Cited by 398
Biological applications of microfluidic gradient devices
Kim, S., Kim, H. J., & Jeon, N. L. (2010) · Integrative Biology · doi:10.1039/c0ib00055h · Cited by 366
Self-citationMicrofluidics without pumps: reinventing the T-sensor and H-filter in paper networks
Osborn, J. L., Lutz, B., Fu, E., Kauffman, P., Stevens, D. Y., & Yager, P. (2010) · Lab on a Chip · doi:10.1039/c004821f · Cited by 338
Magnetite nanoparticles: Synthesis methods – A comparative review
Niculescu, A.-G., Chircov, C., & Grumezescu, A. M. (2022) · Methods · doi:10.1016/j.ymeth.2021.04.018 · Cited by 331
Wong, J. Y., Leach, J. B., & Brown, X. Q. (2004) · Surface Science · doi:10.1016/j.susc.2004.06.186 · Cited by 323
Metabolic gene regulation in a dynamically changing environment
Bennett, M. R., Pang, W. L., Ostroff, N. A., Baumgartner, B. L., Nayak, S., Tsimring, L. S., & Hasty, J. (2008) · Nature · doi:10.1038/nature07211 · Cited by 287
Differential effects of EGF gradient profiles on MDA-MB-231 breast cancer cell chemotaxis
Wang, S.-J., Saadi, W., Lin, F., Minh-Canh Nguyen, C., & Li Jeon, N. (2004) · Experimental Cell Research · doi:10.1016/j.yexcr.2004.06.030 · Cited by 277
Microfluidics for cell-based high throughput screening platforms—A review
Du, G., Fang, Q., & den Toonder, J. M. J. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.11.023 · Cited by 276
Microfluidic platforms for mechanobiology
Polacheck, W. J., Li, R., Uzel, S. G. M., & Kamm, R. D. (2013) · Lab on a Chip · doi:10.1039/c3lc41393d · Cited by 272
Zaari, N., Rajagopalan, P., Kim, S. K., Engler, A. J., & Wong, J. Y. (2004) · Advanced Materials · doi:10.1002/adma.200400883 · Cited by 268
Concentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
Microfluidic Organ‐on‐a‐Chip Technology for Advancement of Drug Development and Toxicology
Caplin, J. D., Granados, N. G., James, M. R., Montazami, R., & Hashemi, N. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500040 · Cited by 205
Microfluidic 3D models of cancer
Sung, K. E., & Beebe, D. J. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.07.002 · Cited by 190
Chang, C.-W., Cheng, Y.-J., Tu, M., Chen, Y.-H., Peng, C.-C., Liao, W.-H., & Tung, Y.-C. (2014) · Lab Chip · doi:10.1039/c4lc00732h · Cited by 154
Microfluidic devices for in vitro studies on liver drug metabolism and toxicity
van Midwoud, P. M., Verpoorte, E., & Groothuis, G. M. M. (2011) · Integrative Biology · doi:10.1039/c0ib00119h · Cited by 115
Kim, H. S., Weiss, T. L., Thapa, H. R., Devarenne, T. P., & Han, A. (2014) · Lab on a Chip · doi:10.1039/c3lc51396c · Cited by 106
A microfluidic multi-injector for gradient generation
Chung, B. G., Lin, F., & Jeon, N. L. (2006) · Lab on a Chip · doi:10.1039/b512667c · Cited by 104
Self-citationA review of chemical gradient systems for cell analysis
Somaweera, H., Ibraguimov, A., & Pappas, D. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.12.008 · Cited by 98
Simultaneous or Sequential Orthogonal Gradient Formation in a 3D Cell Culture Microfluidic Platform
Uzel, S. G. M., Amadi, O. C., Pearl, T. M., Lee, R. T., So, P. T. C., & Kamm, R. D. (2016) · Small · doi:10.1002/smll.201501905 · Cited by 100
Zou, H., Yue, W., Yu, W.-K., Liu, D., Fong, C.-C., Zhao, J., & Yang, M. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00873 · Cited by 47
Sun, M., & Vanapalli, S. A. (2013) · Analytical Chemistry · doi:10.1021/ac303526y · Cited by 26
Metadata
- Authors
- Jeon, N. L., Dertinger, S. K. W., Chiu, D. T., Choi, I. S., Stroock, A. D., & Whitesides, G. M.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-10-01
- Volume
- 16
- Issue
- 22
- Pages
- 8311-8316
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W1969435013
- Cited by
- 963
- References
- 13
- FWCI
- 12.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.