The DOI matches its Crossref record.
Micropatterns of Chemisorbed Cell Adhesion-Repellent Films Using Oxygen Plasma Etching and Elastomeric Masks
Abstract
Cellular micropatterning has become an important tool to precisely design cell-to-substrate attachment for cell biology studies, tissue engineering, cell-based biosensors, biological assays, and drug screens. This paper describes a new technique for micropatterning of cells that is based on the use of oxygen plasma as a patterning tool. The technique consists of (1) homogeneously grafting a glass substrate with a protein-repellent interpenetrating polymeric network (IPN) of poly(acrylamide) and poly(ethyleneglycol) [P(AAm- co -EG)] prepared with commercially available reagents and (2) selectively removing this coating using oxygen plasma. We use elastomeric stencils (i.e. self-sealing membranes with through-holes) and microchannels as removable masks for the selective oxygen plasma etch of the IPN areas that are not protected by the mask. The stencil or microchannels are peeled off to reveal cell-adhesive regions separated by the nonadhesive coating. Our method offers a convenient way of patterning a robust protein-repelling material, allows for independently controlling the chemistry of the regions reserved for cell attachment, and can be used to create coculture systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Collective migration of an epithelial monolayer in response to a model wound
Poujade, M., Grasland-Mongrain, E., Hertzog, A., Jouanneau, J., Chavrier, P., Ladoux, B., Buguin, A., & Silberzan, P. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0705062104 · Cited by 912
Differentiation-on-a-chip: A microfluidic platform for long-term cell culture studies
Tourovskaia, A., Figueroa-Masot, X., & Folch, A. (2005) · Lab on a Chip · doi:10.1039/b405719h · Cited by 363
Self-citationThe Evolution of Polystyrene as a Cell Culture Material
Lerman, M. J., Lembong, J., Muramoto, S., Gillen, G., & Fisher, J. P. (2018) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2018.0056 · Cited by 258
Self-organizing human cardiac microchambers mediated by geometric confinement
Ma, Z., Wang, J., Loskill, P., Huebsch, N., Koo, S., Svedlund, F. L., Marks, N. C., Hua, E. W., Grigoropoulos, C. P., Conklin, B. R., et al. (2015) · Nature Communications · doi:10.1038/ncomms8413 · Cited by 214
Self-citationHoang, P., Wang, J., Conklin, B. R., Healy, K. E., & Ma, Z. (2018) · Nature Protocols · doi:10.1038/nprot.2018.006 · Cited by 156
Self-citationModulus-dependent macrophage adhesion and behavior
Irwin, E. F., Saha, K., Rosenbluth, M., Gamble, L. J., Castner, D. G., & Healy, K. E. (2008) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856208786052407 · Cited by 105
Self-citationA microfluidic co-culture system to monitor tumor-stromal interactions on a chip
Menon, N. V., Chuah, Y. J., Cao, B., Lim, M., & Kang, Y. (2014) · Biomicrofluidics · doi:10.1063/1.4903762 · Cited by 53
Metadata
- Authors
- Tourovskaia, A., Barber, T., Wickes, B. T., Hirdes, D., Grin, B., Castner, D. G., Healy, K. E., & Folch, A.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-04-26
- Volume
- 19
- Issue
- 11
- Pages
- 4754-4764
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2086605876
- Cited by
- 159
- References
- 0
- FWCI
- 3.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.