Potentiometric Method for Determination of Microclimate pH in Poly(lactic-co-glycolic acid) Films
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The acidic microclimate pH (μpH) in poly(lactide- co -glycolide) (PLGA) devices has been identified as a major source of instability of encapsulated proteins and acid labile small molecules. A fast and reliable potentiometric technique for μpH measurement in thin PLGA films was developed and validated. Standard glass pH electrodes were coated with PLGA films, and the zero-current potential was measured with respect to a calomel reference electrode. The measurement was independent of external media pH but responsive to addition to the polymer films buffering salts from lyophilized solutions of various pH values. The contribution of additional diffusion and interfacial potentials in the electrochemical cell due to the presence polymer coating was determined to be roughly ≤0.2 pH units by two independent measurements and slightly pH dependent. A highly acidic μpH (μpH <3) developed in PLGA 50/50 films (∼30−100 μm thick) after 1 day of incubation in a physiological buffer at 37 °C and remained acidic for 4 weeks. The μpH varied significantly with the thickness of the coating during extended incubation. The μpH of a 7 μm thick coating rose to a neutral value (pH 6.5) after 1 week of incubation, but it remained acidic (pH 2−3.5) for 250 and 30 μm thick coatings. Hence, the microclimate pH measurement described here may be useful for mechanistic evaluation and μpH control of biodegradable polymer systems encapsulating labile molecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrolytic degradation of devices based on poly(DL-lactic acid) size-dependence
Grizzi, I., Garreau, H., Li, S., & Vert, M. (1995) · Biomaterials · doi:10.1016/0142-9612(95)93258-f · Cited by 895
Li, S. M., Garreau, H., & Vert, M. (1990) · Journal of Materials Science: Materials in Medicine · doi:10.1007/bf00700871 · Cited by 733
Chain-end scission in acid catalyzed hydrolysis of poly (d,l-lactide) in solution
Shih, C. (1995) · Journal of Controlled Release · doi:10.1016/0168-3659(94)00100-9 · Cited by 159
Cited by
Effect of acidic pH on PLGA microsphere degradation and release
Zolnik, B. S., & Burgess, D. J. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2007.05.034 · Cited by 560
Ford Versypt, A. N., Pack, D. W., & Braatz, R. D. (2013) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.10.015 · Cited by 345
Chemical degradation of peptides and proteins in PLGA: A review of reactions and mechanisms
Houchin, M. L., & Topp, E. M. (2008) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21176 · Cited by 277
Injectable controlled release depots for large molecules
Schwendeman, S. P., Shah, R. B., Bailey, B. A., & Schwendeman, A. S. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.057 · Cited by 206
“coating thin films of PLGA onworking glass electrodes [109].”
BackgroundSelf-citationDing, A. G., & Schwendeman, S. P. (2008) · Pharmaceutical Research · doi:10.1007/s11095-008-9594-3 · Cited by 163
“inside polymer electrode-coating films (21), the correlation between pH measured between electrode surface and polymer coating and smaller size systems such as microspheres may be difficult, due to the unique microstructure and transport”
BackgroundSelf-citation
Metadata
- Authors
- Shenderova, A., Ding, A. G., & Schwendeman, S. P.
- Venue
- Macromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-12-01
- Volume
- 37
- Issue
- 26
- Pages
- 10052-10058
- ISSN
- 0024-9297 (ISSN-L)
- 1520-5835
- OpenAlex
- W2024740639
- Cited by
- 38
- References
- 3
- FWCI
- 1.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Potentiometric Method for Determination of Microclimate pH in Poly(lactic-co-glycolic acid) Films. https://app.cochat.ai/papers/10.1021/ma0481959
- The paper
- Shenderova, A., Ding, A. G., & Schwendeman, S. P. (2004). Potentiometric Method for Determination of Microclimate pH in Poly(lactic-co-glycolic acid) Films. Macromolecules. https://doi.org/10.1021/ma0481959
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.